Prospective Study on Noninvasive Assessment of Intracranial Pressure in Traumatic Brain-Injured Patients: Comparison of Four Methods

被引:66
作者
Cardim, Danilo [1 ]
Robba, Chiara [2 ]
Donnelly, Joseph [1 ]
Bohdanowicz, Michal [3 ]
Schmidt, Bernhard [4 ]
Damian, Maxwell [5 ]
Varsos, Georgios V. [1 ]
Liu, Xiuyun [1 ]
Cabeleira, Manuel [1 ]
Frigieri, Gustavo [6 ]
Cabella, Brenno [1 ]
Smielewski, Peter [1 ]
Mascarenhas, Sergio [6 ]
Czosnyka, Marek [1 ,3 ]
机构
[1] Univ Cambridge, Dept Clin Neurosci, Div Neurosurg, Brain Phys Lab, Box 167,Cambridge Biomed Campus, Cambridge CB2 0QQ, England
[2] Cambridge Univ Hosp NHS Fdn Trust, Addenbrookes Hosp, Neurosci Crit Care Unit, Cambridge, England
[3] Warsaw Univ Technol, Inst Elect Syst, Warsaw, Poland
[4] Univ Hosp Chemnitz, Dept Neurol, Chemnitz, Germany
[5] Cambridge Univ Hosp NHS Fdn Trust, Addenbrookes Hosp, Dept Neurol, Cambridge, England
[6] Univ Sao Paulo, Phys Inst Sao Carlos, Sao Carlos, SP, Brazil
关键词
traumatic brain injury; noninvasive ICP monitoring; transcranial Doppler; CEREBRAL PERFUSION-PRESSURE; TRANSCRANIAL DOPPLER SONOGRAPHY; CRITICAL CLOSING PRESSURE; PULSATILITY INDEX; CLINICAL-EXPERIENCE; BLOOD-FLOW; ICP; ULTRASONOGRAPHY; PREDICTION; DYNAMICS;
D O I
10.1089/neu.2015.4134
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Elevation of intracranial pressure (ICP) may occur in many diseases, and therefore the ability to measure it noninvasively would be useful. Flow velocity signals from transcranial Doppler (TCD) have been used to estimate ICP; however, the relative accuracy of these methods is unclear. This study aimed to compare four previously described TCD-based methods with directly measured ICP in a prospective cohort of traumatic brain-injured patients. Noninvasive ICP (nICP) was obtained using the following methods: 1) a mathematical "black-box" model based on interaction between TCD and arterial blood pressure (nICP_BB); 2) based on diastolic flow velocity (nICP_FVd); 3) based on critical closing pressure (nICP_CrCP); and 4) based on TCD-derived pulsatility index (nICP_PI). In time domain, for recordings including spontaneous changes in ICP greater than 7 mm Hg, nICP_PI showed the best correlation with measured ICP (R = 0.61). Considering every TCD recording as an independent event, nICP_BB generally showed to be the best estimator of measured ICP (R = 0.39; p < 0.05; 95% confidence interval [CI] = 9.94 mm Hg; area under the curve [AUC] = 0.66; p < 0.05). For nICP_FVd, although it presented similar correlation coefficient to nICP_BB and marginally better AUC (0.70; p < 0.05), it demonstrated a greater 95% CI for prediction of ICP (14.62 mm Hg). nICP_CrCP presented a moderate correlation coefficient (R = 0.35; p < 0.05) and similar 95% CI to nICP_BB (9.19 mm Hg), but failed to distinguish between normal and raised ICP (AUC = 0.64; p > 0.05). nICP_PI was not related to measured ICP using any of the above statistical indicators. We also introduced a new estimator (nICP_Av) based on the average of three methods (nICP_BB, nICP_FVd, and nICP_CrCP), which overall presented improved statistical indicators (R = 0.47; p < 0.05; 95% CI = 9.17 mm Hg; AUC = 0.73; p < 0.05). nICP_PI appeared to reflect changes in ICP in time most accurately. nICP_BB was the best estimator for ICP "as a number." nICP_Av demonstrated to improve the accuracy of measured ICP estimation.
引用
收藏
页码:792 / 802
页数:11
相关论文
共 49 条
[1]   MR-intracranial pressure (ICP): A method to measure intracranial elastance and pressure noninvasively by means of MR imaging: Baboon and human study [J].
Alperin, NJ ;
Lee, SH ;
Loth, F ;
Raksin, PB ;
Lichtor, T .
RADIOLOGY, 2000, 217 (03) :877-885
[2]   Monitoring of increased intracranial pressure resulting from cerebral edema with transcranial Doppler sonography in patients with middle cerebral artery infarction [J].
Asil, T ;
Uzunca, I ;
Utku, U ;
Berberoglu, U .
JOURNAL OF ULTRASOUND IN MEDICINE, 2003, 22 (10) :1049-1053
[3]   Ophthalmic Artery as a Sensor for Non-invasive Intracranial Pressure Measurement Electronic System [J].
Bartusis, L. ;
Zakelis, R. ;
Daubaris, G. ;
Ragauskas, A. ;
Rutkauskas, S. ;
Matijosaitis, V. ;
Preiksaitis, A. .
ELEKTRONIKA IR ELEKTROTECHNIKA, 2012, 122 (06) :45-48
[4]   Transcranial Doppler sonography pulsatility index (PI) reflects intracranial pressure (ICP) [J].
Bellner, J ;
Romner, B ;
Reinstrup, P ;
Kristiansson, KA ;
Ryding, E ;
Brandt, L .
SURGICAL NEUROLOGY, 2004, 62 (01) :45-51
[5]  
Budohoski Karol P, 2012, Acta Neurochir Suppl, V114, P121, DOI 10.1007/978-3-7091-0956-4_22
[6]  
Bullock R., 2007, J Neurotrauma, V24, pS1, DOI DOI 10.1089/NEU.2007.9999
[7]   THE EFFECT OF CHANGES IN CEREBRAL PERFUSION-PRESSURE UPON MIDDLE CEREBRAL-ARTERY BLOOD-FLOW VELOCITY AND JUGULAR BULB VENOUS OXYGEN-SATURATION AFTER SEVERE BRAIN INJURY [J].
CHAN, KH ;
MILLER, JD ;
DEARDEN, NM ;
ANDREWS, PJD ;
MIDGLEY, S .
JOURNAL OF NEUROSURGERY, 1992, 77 (01) :55-61
[8]   Monitoring and interpretation of intracranial pressure [J].
Czosnyka, M ;
Pickard, JD .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2004, 75 (06) :813-821
[9]  
Czosnyka M, 1998, J Neurosurg, V88, P802
[10]   FREQUENCY-DEPENDENT PROPERTIES OF CEREBRAL BLOOD TRANSPORT - AN EXPERIMENTAL-STUDY IN ANESTHETIZED RABBITS [J].
CZOSNYKA, M ;
RICHARDS, H ;
PICKARD, JD ;
HARRIS, N ;
IYER, V .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (04) :391-399