Koopman Analysis Based Wide-Area Back-Up Protection and Faulted Line Identification for Series-Compensated Power Network

被引:21
作者
Dubey, Rahul [1 ]
Samantaray, Subhransu Ranjan [2 ]
Panigrahi, Bijaya Ketan [3 ]
Venkoparao, Vijendran G. [4 ]
机构
[1] ABB Res & Dev Ctr, Dept Power Grid Grid Automat, Bengaluru 560048, India
[2] Indian Inst Technol, Sch Elect Sci, Bhubaneswar 751013, Orissa, India
[3] Indian Inst Technol Delhi, Dept Elect Engn, New Delhi 110016, India
[4] Robert Bosch Engn & Business Solut Ltd, Bangaluru 560095, Karnataka, India
来源
IEEE SYSTEMS JOURNAL | 2018年 / 12卷 / 03期
关键词
Faulted bus identification (FBI); faulted line identification (FLI); Koopman mode (KM); phasor measurement units (PMUs); power swing; wide-area back-up protections (WABPs); ALGORITHM; LOCATION; SYSTEMS; MODES;
D O I
10.1109/JSYST.2016.2615898
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The paper presents wide-area back-up protection (WABP) and faulted line identification (FLI) scheme for series-compensated power transmission network. The proposed scheme uses the Koopman mode technique on fault current data obtained from phasor measurement units for WABP and FLI. The main advantage of the proposed scheme is that it is based on spatiotemporal information system (STIS). As we know that in real-world applications, often time and space exist together, and hence, dealing with spatial aspect without considering temporal aspect is of limited use. Similarly, the introduction of series compensation in a power transmission network is common nowadays due to many technical benefits. The FLI in a power network with series-compensation is more complicated due to complex transients produced by series capacitor and the metal-oxide varistor. The proposed scheme is developed using STIS for WABP and FLI under stressed conditions including power swing and load encroachment. The New England 39 bus system is used as the test system, which is developed on Dig-Silent power factory commercial software (PF4C) platform for evaluating the performance of the proposed technique. Further, the efficacy of the proposed scheme is also tested for other critical situations such as symmetrical fault during power swing and multievent detection and found to work effectively.
引用
收藏
页码:2634 / 2644
页数:11
相关论文
共 32 条
[1]   Fault Location of Uncompensated/Series-compensated Lines Using Two-end Synchronized Measurements [J].
Abdelaziz, A. Y. ;
Mekhamer, S. F. ;
Ezzat, M. .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2013, 41 (07) :693-715
[2]   Wide area protection - Technology and infrastructures [J].
Adamiak, MG ;
Apostolov, AP ;
Begovic, MM ;
Heriville, CF ;
Martin, KE ;
Michel, GL ;
Phadke, AG ;
Thorp, JS .
IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (02) :601-609
[3]   Advances in Series-Compensated Line Protection [J].
Altuve, Hector J. ;
Mooney, Joseph B. ;
Alexander, George E. .
2009 62ND ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2009, :263-275
[4]  
Bogdan Kasztenny, 2001, P 27 ANN W PROT REL, P22
[5]   Smart Transmission Grid Applications and Their Supporting Infrastructure [J].
Bose, Anjan .
IEEE TRANSACTIONS ON SMART GRID, 2010, 1 (01) :11-19
[6]   A Novel Back Up Wide Area Protection Technique for Power Transmission Grids Using Phasor Measurement Unit [J].
Eissa, M. M. ;
Masoud, M. Elshahat ;
Elanwar, M. Magdy Mohamed .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (01) :270-278
[7]   A Novel Backup Distance Protection Scheme for Series-Compensated Transmission Lines [J].
Hashemi, S. M. ;
Hagh, M. Tarafdar ;
Seyedi, H. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (02) :699-707
[8]   Wide-Area Backup Protection Algorithm Based on Fault Component Voltage Distribution [J].
He, Zhiqin ;
Zhang, Zhe ;
Chen, Wei ;
Malik, Om P. ;
Yin, Xianggen .
IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (04) :2752-2760
[9]   Third zone revisited [J].
Horowitz, SH ;
Phadke, AG .
IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (01) :23-29
[10]   A new protection scheme for fault detection, direction discrimination, classification, and location in transmission lines [J].
Jiang, JA ;
Chen, CS ;
Liu, CW .
IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (01) :34-42