Indoor/outdoor air pollution relationships in ten commercial buildings: PM2.5 and NO2

被引:104
作者
Challoner, Avril [1 ]
Gill, Laurence [1 ]
机构
[1] Univ Dublin Trinity Coll, Dept Civil Struct & Environm Engn, Dublin 2, Ireland
关键词
NO2; PM2.5; Indoor air quality; Urban environment; Buildings; Ventilation; AIRBORNE PARTICULATE MATTER; NITROGEN-DIOXIDE; PERSONAL EXPOSURES; ORGANIC-COMPOUNDS; OFFICE WORKERS; OUTDOOR AIR; INDOOR; URBAN; QUALITY; POLLUTANTS;
D O I
10.1016/j.buildenv.2014.05.032
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
PM2.5 and NO2 concentrations were measured simultaneously indoors and outdoors for ten different city centre buildings (shops and offices) in Dublin, Ireland. Outdoor concentrations were measured in two locations either at ground level outside the building or at the air intake of the building's ventilation system. The ratio of indoor to outdoor (I/O) PM2.5 concentrations were all found to be close to or above 1, indicating that either the fabric and/or operational environment of the buildings, whether naturally or mechanically ventilated, was not performing any significant function to reduce particulate concentrations from outdoors or that indoor sources were present. Indoor PM2.5 concentrations during working hours were generally below 25 i.tg I11-3 PM2.5, with naturally ventilated shops showing the highest concentrations. Lower indoor NO2 concentrations were measured during working hours in naturally ventilated buildings compared to the mechanically ventilated buildings, although most buildings showed strong diurnal relationships between outdoor NO2 concentrations and indoor air quality. Indeed, street level concentrations of NO2 seemed to have a stronger influence on the indoor air quality of the mechanically ventilated buildings, than with the corresponding air quality measured at their roof level ventilation intakes. The buildings with the greatest reduction for NO2 were older naturally ventilated offices. I/O ratios of both pollutants, but particularly NO2, increased significantly overnight as outdoor concentrations reduced to a much greater extent than indoors. This would indicate a benefit in promoting increased air exchange between the outdoors and indoors during night time periods in order to flush out air pollutants. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:159 / 173
页数:15
相关论文
共 69 条
  • [1] [Anonymous], 2010, INT J OCCUPATIONAL H
  • [2] [Anonymous], 2010, DUBL REG AIR QUAL MA
  • [3] [Anonymous], 2004, 2 EUR COMM
  • [4] [Anonymous], 2013, Review of Evidence on Health Aspects of Air Pollution-REVIHAAP Project Technical Report
  • [5] [Anonymous], 2010, STATE OUTLOOK 2010 S, DOI DOI 10.2800/45773
  • [6] Influence of traffic on the PM10 and PM2.5 urban aerosol fractions in Madrid (Spain)
    Artíñano, B
    Salvador, P
    Alonso, DG
    Querol, X
    Alastuey, A
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2004, 334 : 111 - 123
  • [7] Indoor and outdoor concentrations of RSP, NO2 and selected volatile organic compounds at 32 shoe stalls located near busy roadways in Seoul, Korea
    Bae, H
    Yang, WH
    Chung, MH
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2004, 323 (1-3) : 99 - 105
  • [8] Indoor air quality in homes, offices and restaurants in Korean urban areas - Indoor/outdoor relationships
    Baek, SO
    Kim, YS
    Perry, R
    [J]. ATMOSPHERIC ENVIRONMENT, 1997, 31 (04) : 529 - 544
  • [9] Baughman AV, 1996, ASHRAE TRAN, V102, P193
  • [10] Spatiotemporal Aspects of Real-Time PM2.5: Low- and Middle-Income Neighborhoods in Bangalore, India
    Both, Adam F.
    Balakrishnan, Arun
    Joseph, Bobby
    Marshall, Julian D.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2011, 45 (13) : 5629 - 5636