Simple and sensitive detection of acrylamide based on hemoglobin immobilization in carbon ionic liquid paste electrode

被引:27
作者
Li, Na [1 ]
Liu, Xiaoying [2 ]
Zhu, Jihe [1 ]
Zhou, Bijing [2 ]
Jing, Junxian [2 ]
Wang, Aibing [3 ]
Xu, Rui [2 ]
Wen, Zhou [4 ]
Shi, Xingbo [1 ]
Guo, Shiyin [1 ]
机构
[1] Hunan Agr Univ HUNAU, Coll Food Sci & Technol, Changsha 410128, Hunan, Peoples R China
[2] Hunan Agr Univ HUNAU, Coll Sci, Changsha 410128, Hunan, Peoples R China
[3] Hunan Agr Univ HUNAU, Coll Vet Med, Key Lab Anim Vaccine & Prot Engn, Lab Anim Models & Funct Genom, Changsha 410128, Hunan, Peoples R China
[4] Guangzhou Univ Chinese Med, Sch Pharmaceut Sci, Waihuan Rd, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Acrylamide; Hemoglobin; Carbon ionic liquid paste electrode; Electrochemical biosensor; Detection; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL BIOSENSOR; AMPEROMETRIC DETECTION; HIGH-PERFORMANCE; NANOPARTICLES; SENSOR; FOODS; GOLD; CONSTRUCTION; EPINEPHRINE;
D O I
10.1016/j.foodcont.2019.106764
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A simple and sensitive electrochemical biosensor for acrylamide (AA) detection based on hemoglobin (Hb) entrapped in ionic liquid-carbon paste was constructed. The Hb-carbon ionic liquid paste electrode (Hb/CILPE) was studied and characterized by scanning electron microscopy (SEM) and electrochemical method. The surface passivation of the Hb/CILPE could be achieved by the addition of acrylamide molecule, which caused the lower current response value owing to the adduct formed by acrylamide and Hb as a result of the reaction between the a-NH2 group and the N-terminal valine of Hb. The experimental conditions such as pH value of supporting electrolyte, pulse increment and concentrated time of AA was examined. Under the optimum conditions, the differential pulse voltammetry (DPV) responses of Hb/CILPE toward AA was evaluated in a good linear range from 1.0 x 10(-11) to 1.0 x 10(-5)M, with a detection limit of 5.0 x 10(-12)M at S/N = 3. This biosensor can be successfully applied to the determination of AA in a real sample without complex pretreatment. Compared with other electrochemical methods for detecting AA, the prepared electrochemical biosensor exhibited advantages of simple preparation, easy surface renewal, better reproducibility and satisfactory stability.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Application of ionic liquid modified carbon ceramic electrode for the sensitive voltammetric detection of rutin
    Zhan, Tianrong
    Sun, Xiaoying
    Wang, Xiuzhen
    Sun, Wei
    Hou, Wanguo
    TALANTA, 2010, 82 (05) : 1853 - 1857
  • [42] Highly sensitive composite electrode based on electrospun carbon nanofibers and ionic liquid
    Liu, Yang
    Wang, Dawei
    Huang, Jianshe
    Hou, Haoqing
    You, Tianyan
    ELECTROCHEMISTRY COMMUNICATIONS, 2010, 12 (08) : 1108 - 1111
  • [43] Development of a sensitive and selective Riboflavin sensor based on carbon ionic liquid electrode
    Safavi, Afsaneh
    Maleki, Norouz
    Ershadifar, Hamid
    Tajabadi, Fariba
    ANALYTICA CHIMICA ACTA, 2010, 674 (02) : 176 - 181
  • [44] Electrochemical deoxyribonucleic acid biosensor based on the self-assembly film with nanogold decorated on ionic liquid modified carbon paste electrode
    Gao, Hongwei
    Qi, Xiaowei
    Chen, Ying
    Sun, Wei
    ANALYTICA CHIMICA ACTA, 2011, 704 (1-2) : 133 - 138
  • [45] Direct electrochemistry of hemoglobin at room temperature ionic liquid [BMIM]PF6 modified carbon paste electrode
    Sun Wei
    Gao Rui-Fang
    Wang Dan-Dan
    Jiao Kui
    ACTA PHYSICO-CHIMICA SINICA, 2007, 23 (08) : 1247 - 1251
  • [46] Fabrication of Hemoglobin/Ionic Liquid Modified Carbon Paste Electrode Based on the Electrodeposition of Gold Nanoparticles/CdS Quantum Dots and Its Electrochemical Application
    Dong, Sheying
    Li, Nan
    Zhang, Penghui
    Li, Yunsheng
    Chen, Zhen
    Huang, Tinglin
    ELECTROANALYSIS, 2012, 24 (07) : 1554 - 1560
  • [47] Synergistic Signal Amplification Based on Ionic Liquid-BaTiO3 Nanoparticle Carbon Paste Electrode for Sensitive Voltammetric Determination of Acetaminophen
    Pourtaheri, Ehsan
    Taher, Mohammad Ali
    Beitollahi, Hadi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY RESEARCH, 2018, 5 (02): : 261 - 271
  • [48] Direct electrochemistry of hemoglobin on an ionic liquid carbon electrode modified with zinc tungstate nanorods
    Ruan, Chengxiang
    Sun, Zhaolan
    Liu, Jun
    Lou, Jin
    Gao, Weimin
    Sun, Wei
    Xiao, Yunsheng
    MICROCHIMICA ACTA, 2012, 177 (3-4) : 457 - 463
  • [49] Direct electrochemistry and electrocatalysis of hemoglobin on gold nanoparticle decorated carbon ionic liquid electrode
    Sun, Wei
    Qin, Peng
    Zhao, Ruijun
    Jiao, Kui
    TALANTA, 2010, 80 (05) : 2177 - 2181
  • [50] Direct Electrochemistry and Electrocatalytic Properties of Hemoglobin Immobilized on Carbon Nanotubes Ionic Liquid Electrode
    Moheimanian, Niloofar
    Raoof, Jahan Bakhsh
    Safavi, Afsaneh
    Ojani, Reza
    ELECTROANALYSIS, 2012, 24 (06) : 1386 - 1393