Simple and sensitive detection of acrylamide based on hemoglobin immobilization in carbon ionic liquid paste electrode

被引:27
作者
Li, Na [1 ]
Liu, Xiaoying [2 ]
Zhu, Jihe [1 ]
Zhou, Bijing [2 ]
Jing, Junxian [2 ]
Wang, Aibing [3 ]
Xu, Rui [2 ]
Wen, Zhou [4 ]
Shi, Xingbo [1 ]
Guo, Shiyin [1 ]
机构
[1] Hunan Agr Univ HUNAU, Coll Food Sci & Technol, Changsha 410128, Hunan, Peoples R China
[2] Hunan Agr Univ HUNAU, Coll Sci, Changsha 410128, Hunan, Peoples R China
[3] Hunan Agr Univ HUNAU, Coll Vet Med, Key Lab Anim Vaccine & Prot Engn, Lab Anim Models & Funct Genom, Changsha 410128, Hunan, Peoples R China
[4] Guangzhou Univ Chinese Med, Sch Pharmaceut Sci, Waihuan Rd, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Acrylamide; Hemoglobin; Carbon ionic liquid paste electrode; Electrochemical biosensor; Detection; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL BIOSENSOR; AMPEROMETRIC DETECTION; HIGH-PERFORMANCE; NANOPARTICLES; SENSOR; FOODS; GOLD; CONSTRUCTION; EPINEPHRINE;
D O I
10.1016/j.foodcont.2019.106764
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A simple and sensitive electrochemical biosensor for acrylamide (AA) detection based on hemoglobin (Hb) entrapped in ionic liquid-carbon paste was constructed. The Hb-carbon ionic liquid paste electrode (Hb/CILPE) was studied and characterized by scanning electron microscopy (SEM) and electrochemical method. The surface passivation of the Hb/CILPE could be achieved by the addition of acrylamide molecule, which caused the lower current response value owing to the adduct formed by acrylamide and Hb as a result of the reaction between the a-NH2 group and the N-terminal valine of Hb. The experimental conditions such as pH value of supporting electrolyte, pulse increment and concentrated time of AA was examined. Under the optimum conditions, the differential pulse voltammetry (DPV) responses of Hb/CILPE toward AA was evaluated in a good linear range from 1.0 x 10(-11) to 1.0 x 10(-5)M, with a detection limit of 5.0 x 10(-12)M at S/N = 3. This biosensor can be successfully applied to the determination of AA in a real sample without complex pretreatment. Compared with other electrochemical methods for detecting AA, the prepared electrochemical biosensor exhibited advantages of simple preparation, easy surface renewal, better reproducibility and satisfactory stability.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Direct electrochemistry of hemoglobin entrapped in dextran film on carbon ionic liquid electrode
    Li, Xiaoqing
    Wang, Yan
    Sun, Xiaoying
    Zhan, Tianrong
    Sun, Wei
    JOURNAL OF CHEMICAL SCIENCES, 2010, 122 (02) : 271 - 278
  • [32] Fabrication and Application of a Sensitive and Highly Stable Copper Hexacyanoferrate Modified Carbon Ionic Liquid Paste Electrode for Hydrogen Peroxide and Glucose Detection
    Haghighi, Behzad
    Nazari, Leila
    Sajjadi, S. Maryam
    ELECTROANALYSIS, 2012, 24 (11) : 2165 - 2175
  • [33] Electrochemical Biosensor Based on Carbon Ionic Liquid Electrode Modified with Nafion/Hemoglobin/DNA Composite Film
    Sun, Wei
    Wang, Yan
    Li, Xiaoqing
    Wu, Jie
    Zhan, Tianrong
    Jiao, Kui
    ELECTROANALYSIS, 2009, 21 (22) : 2454 - 2460
  • [34] An acrylamide biosensor based on immobilization of hemoglobin onto multiwalled carbon nanotube/copper nanoparticles/polyaniline hybrid film
    Batra, Bhawna
    Lata, Suman
    Sharma, Madhu
    Pundir, C. S.
    ANALYTICAL BIOCHEMISTRY, 2013, 433 (02) : 210 - 217
  • [35] Sensitive voltammetric determination of diclofenac using room-temperature ionic liquid-modified carbon nanotubes paste electrode
    Ensafi, Ali A.
    Izadi, Maedeh
    Karimi-Maleh, Hassan
    IONICS, 2013, 19 (01) : 137 - 144
  • [36] Sensitive Voltammetric Detection of Metol with a TiO2 Nanowire Modified Carbon Ionic Liquid Electrode
    Niu, Xueliang
    Yan, Lijun
    Li, Xiaobao
    Hu, Anhui
    Zheng, Caijuan
    Zhang, Yiliang
    Sun, Wei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (02): : 1720 - 1729
  • [37] Nitrite electrochemical sensor for food analysis based on direct immobilization of hemoglobin on multi-walled carbon nanotube ionic liquid electrode
    Moheimanian, Niloofar
    Raoof, Jahan Bakhsh
    Safavi, Afsaneh
    Ojani, Reza
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2014, 11 (04) : 1217 - 1222
  • [38] Nitrite electrochemical sensor for food analysis based on direct immobilization of hemoglobin on multi-walled carbon nanotube ionic liquid electrode
    Niloofar Moheimanian
    Jahan Bakhsh Raoof
    Afsaneh Safavi
    Reza Ojani
    Journal of the Iranian Chemical Society, 2014, 11 : 1217 - 1222
  • [39] Electrochemical Detection of Hydrazine by Carbon Paste Electrode Modified with Ferrocene Derivatives, Ionic Liquid, and CoS2-Carbon Nanotube Nanocomposite
    Tajik, Somayeh
    Beitollahi, Hadi
    Hosseinzadeh, Rahman
    Afshar, Abbas Aghaei
    Varma, Rajender S.
    Jang, Ho Won
    Shokouhimehr, Mohammadreza
    ACS OMEGA, 2021, 6 (07): : 4641 - 4648
  • [40] Facile immobilization of cholesterol oxidase on Pt,Ru-C nanocomposite and ionic liquid-modified carbon paste electrode for an efficient amperometric free cholesterol biosensing
    Mutic, Sanja
    Stankovic, Dalibor
    Konya, Zoltan
    Anojcic, Jasmina
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (23) : 5709 - 5722