Simple and sensitive detection of acrylamide based on hemoglobin immobilization in carbon ionic liquid paste electrode

被引:27
|
作者
Li, Na [1 ]
Liu, Xiaoying [2 ]
Zhu, Jihe [1 ]
Zhou, Bijing [2 ]
Jing, Junxian [2 ]
Wang, Aibing [3 ]
Xu, Rui [2 ]
Wen, Zhou [4 ]
Shi, Xingbo [1 ]
Guo, Shiyin [1 ]
机构
[1] Hunan Agr Univ HUNAU, Coll Food Sci & Technol, Changsha 410128, Hunan, Peoples R China
[2] Hunan Agr Univ HUNAU, Coll Sci, Changsha 410128, Hunan, Peoples R China
[3] Hunan Agr Univ HUNAU, Coll Vet Med, Key Lab Anim Vaccine & Prot Engn, Lab Anim Models & Funct Genom, Changsha 410128, Hunan, Peoples R China
[4] Guangzhou Univ Chinese Med, Sch Pharmaceut Sci, Waihuan Rd, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Acrylamide; Hemoglobin; Carbon ionic liquid paste electrode; Electrochemical biosensor; Detection; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL BIOSENSOR; AMPEROMETRIC DETECTION; HIGH-PERFORMANCE; NANOPARTICLES; SENSOR; FOODS; GOLD; CONSTRUCTION; EPINEPHRINE;
D O I
10.1016/j.foodcont.2019.106764
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A simple and sensitive electrochemical biosensor for acrylamide (AA) detection based on hemoglobin (Hb) entrapped in ionic liquid-carbon paste was constructed. The Hb-carbon ionic liquid paste electrode (Hb/CILPE) was studied and characterized by scanning electron microscopy (SEM) and electrochemical method. The surface passivation of the Hb/CILPE could be achieved by the addition of acrylamide molecule, which caused the lower current response value owing to the adduct formed by acrylamide and Hb as a result of the reaction between the a-NH2 group and the N-terminal valine of Hb. The experimental conditions such as pH value of supporting electrolyte, pulse increment and concentrated time of AA was examined. Under the optimum conditions, the differential pulse voltammetry (DPV) responses of Hb/CILPE toward AA was evaluated in a good linear range from 1.0 x 10(-11) to 1.0 x 10(-5)M, with a detection limit of 5.0 x 10(-12)M at S/N = 3. This biosensor can be successfully applied to the determination of AA in a real sample without complex pretreatment. Compared with other electrochemical methods for detecting AA, the prepared electrochemical biosensor exhibited advantages of simple preparation, easy surface renewal, better reproducibility and satisfactory stability.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Sensitive and Simple Electrochemical Detection of Lead(II) with Carbon Ionic Liquid Electrode
    Liu, He-Jian
    Qu, Li-Ning
    Hu, Song
    Zhan, Tian-Rong
    Zhao, Chao-Zhi
    Sun, Wei
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2010, 57 (6B) : 1367 - 1373
  • [2] Construction of Poly(methylene blue) on Carbon Nanotubes Ionic Liquid Paste Electrode for Sensitive Detection of Nitrite
    Li, Yonghong
    Liu, Xinling
    Zeng, Xiandong
    Liu, Xiaoying
    Tao, Ling
    Wei, Wanzhi
    Luo, Shenglian
    SENSOR LETTERS, 2010, 8 (04) : 584 - 590
  • [3] Ion transfer at carbon paste electrode based on ionic liquid
    Shul, Galyna
    Sirieix-Plenet, Juliette
    Gaillon, Laurent
    Opallo, Marcin
    ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (07) : 1111 - 1114
  • [4] Comparative investigation on electrochemical behavior of hydroquinone at carbon ionic liquid electrode, ionic liquid modified carbon paste electrode and carbon paste electrode
    Zhang, Ya
    Zheng, Jian Bin
    ELECTROCHIMICA ACTA, 2007, 52 (25) : 7210 - 7216
  • [5] Sensitive voltammetric determination of rutin at an ionic liquid modified carbon paste electrode
    Zhanga, Ya
    Zhenga, Jianbin
    TALANTA, 2008, 77 (01) : 325 - 330
  • [6] Electrochemical performance of a new imidazolium ionic liquid crystal and carbon paste composite electrode for the sensitive detection of paracetamol
    Mangaiyarkarasi, R.
    Premlatha, S.
    Khan, Rajkumar
    Pratibha, R.
    Umadevi, S.
    JOURNAL OF MOLECULAR LIQUIDS, 2020, 319 (319)
  • [7] Direct electrochemistry of hemoglobin and its electrocatalytic effect based on its direct immobilization on carbon ionic liquid electrode
    Safavi, Afsaneh
    Maleki, Norouz
    Moradlou, Omran
    Sorouri, Mohsen
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (03) : 420 - 423
  • [8] Electrochemical Determination of Riboflavin by an Ionic Liquid Modified Carbon Paste Electrode as a Sensitive Sensor
    Zarei, Ebrahim
    Jamali, Mohammad Reza
    Bagheri, Jaber
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (06): : 642 - 657
  • [9] Electrocatalytic oxidation of formaldehyde on nickel modified ionic liquid carbon paste electrode as a simple and efficient electrode
    Reza Ojani
    Jahan-Bakhsh Raoof
    Saeid Safshekan
    Journal of Applied Electrochemistry, 2012, 42 : 81 - 87
  • [10] Electrocatalytic oxidation of formaldehyde on nickel modified ionic liquid carbon paste electrode as a simple and efficient electrode
    Ojani, Reza
    Raoof, Jahan-Bakhsh
    Safshekan, Saeid
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2012, 42 (02) : 81 - 87