Ultrasound detection using polymer microring optical resonator

被引:69
作者
Ashkenazi, S [1 ]
Chao, CY
Guo, LJ
O'Donnell, M
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Elect Engn & Comp Sci, Solid State Elect Lab, Ann Arbor, MI 48109 USA
关键词
D O I
10.1063/1.1829775
中图分类号
O59 [应用物理学];
学科分类号
摘要
Application of polymer waveguide microring resonators for high-frequency ultrasound detection is presented. The device consists of a microring optical resonator coupled to a straight optical waveguide which serves as input and output ports. Acoustic waves irradiating the ring waveguide induce strain modifying the waveguide cross section. As a consequence, the effective refractive index of optical waves propagating along the ring is modified. The sharp wavelength dependence of the high Q-factor resonator enhances the optical response to acoustic strain. High sensitivity is demonstrated experimentally in detecting broadband ultrasound pulses from a 10 MHz transducer. Methods of extending the technique to form multi-element ultrasonic arrays for imaging applications are proposed. (C) 2004 American Institute of Physics.
引用
收藏
页码:5418 / 5420
页数:3
相关论文
共 11 条
[1]   Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detection [J].
Beard, PC ;
Pérennès, F ;
Mills, TN .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (06) :1575-1582
[2]   Thermoelastic expansion vs. piezoelectricity for high-frequency, 2-D arrays [J].
Buma, T ;
Spisar, M ;
O'Donnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2003, 50 (08) :1065-1068
[3]   Biochemical sensors based on polymer microrings with sharp asymmetrical resonance [J].
Chao, CY ;
Guo, LJ .
APPLIED PHYSICS LETTERS, 2003, 83 (08) :1527-1529
[4]   Polymer microring resonators fabricated by nanoimprint technique [J].
Chao, CY ;
Guo, LJ .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2002, 20 (06) :2862-2866
[5]   High frequency optoacoustic arrays using etalon detection [J].
Hamilton, JD ;
Buma, T ;
Spisar, M ;
O'Donnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (01) :160-169
[6]   Sensor based on an integrated optical microcavity [J].
Krioukov, E ;
Klunder, DJW ;
Driessen, A ;
Greve, J ;
Otto, C .
OPTICS LETTERS, 2002, 27 (07) :512-514
[7]   Integrated optical microcavities for enhanced evanescent-wave spectroscopy [J].
Krioukov, E ;
Klunder, DJW ;
Driessen, A ;
Greve, J ;
Otto, C .
OPTICS LETTERS, 2002, 27 (17) :1504-1506
[8]   Comparison of the photothermal sensitivity of an interferometric optical fiber probe with pulsed photothermal radiometry [J].
Laufer, JG ;
Beard, PC ;
Mills, TN .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (09) :3345-3352
[9]   Second-order filtering and sensing with partially coupled traveling waves in a single resonator [J].
Little, BE ;
Chu, ST ;
Haus, HA .
OPTICS LETTERS, 1998, 23 (20) :1570-1572
[10]   Precise control of wavelength channel spacing of microring resonator add-drop filter array [J].
Suzuki, S ;
Hatakeyama, Y ;
Kokubun, Y ;
Chu, ST .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 2002, 20 (04) :745-750