Contact force facilitates the achievement of an unexcitable ablation line during pulmonary vein isolation

被引:11
作者
Schaeffer, Benjamin [1 ]
Willems, Stephan [1 ]
Meyer, Christian [1 ]
Lueker, Jakob [2 ]
Akbulak, Ruken O. [1 ]
Moser, Julia [1 ]
Jularic, Mario [1 ]
Eickholt, Christian [1 ]
Schwarzl, Jana M. [1 ]
Gunawardene, Melanie [1 ]
Kuklik, Pawel [1 ]
Sultan, Arian [2 ]
Hoffmann, Boris A. [3 ]
Steven, Daniel [2 ]
机构
[1] Univ Hosp Hamburg, Univ Heart Ctr, Dept Cardiol Electrophysiol, Martinistr 52, D-20246 Hamburg, Germany
[2] Univ Hosp Cologne, Dept Cardiol Electrophysiol, Cologne, Germany
[3] Univ Hosp Mainz, Dept Cardiol Electrophysiol, Mainz, Germany
关键词
Ablation; Paroxysmal atrial fibrillation; Pulmonary vein isolation; Contact force; Unexcitability; LEFT ATRIAL ABLATION; CATHETER ABLATION; RADIOFREQUENCY ABLATION; PACE CAPTURE; SENSING TECHNOLOGY; FIBRILLATION; RECONNECTION; SYSTEM; PREDICTION; CONDUCTION;
D O I
10.1007/s00392-018-1228-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Contact force (CF) catheters provide catheter-tissue contact information to improve outcome of pulmonary vein isolation (PVI) in paroxysmal atrial fibrillation (PAF). We evaluated different target-CF values for achievement of the additional endpoint of an unexcitable ablation line. Methods A total of 106 patients undergoing PVI were randomized into three groups (G) (G1: target-CF 15 g, G2: target-CF 10 g, G3: CF concealed from operator). The PVI encircling line was divided into predefined sections. Excitable tissue along the PVI-line identified by high output pacing (10 V, 2 ms) was targeted for further ablation. Results Mean average CF was 17.4 +/- 4.7 g (G1) vs. 12.3 +/- 6.0 g (G2) vs. 11.1 +/- 6.5 g (G 3) (p < 0.001). Primary unexcitable ablation lines were found in 38.6, 19.4 and 5.7% (G1, G2, G3 respectively; G1 vs. G2 p < 0.05, G1 vs. G3 p < 0.001, G2 vs. G3 ns). Additional radiofrequency (RF)-energy to achieve unexcitability was lowest in G1 (3.6 +/- 3.1 kJ vs. 8.6 +/- 7.2 kJ (G2) and 10.4 +/- 6.7 (G3), p <= 0.001, G2 vs. G3 ns) with accordingly lowest additional RF applications in G1 (3.0 +/- 2.6 vs. 7.0 +/- 5.4 in G2 and 8.4 +/- 4.0 in G3; G1 vs. G2 and G3, p < 0.001, G 2 vs. G 3 ns). Sections along ablation lines with low initial CF were most likely to reveal excitability. Single procedure success was 81.9 vs. 73.5 vs. 71.4% (G 1, 2 and 3, p = 0.6) during 437 +/- 254 day follow-up. Conclusion Higher tip-to-tissue CF during PVI facilitates the achievement of an unexcitable ablation line, requiring less additional RF-energy.
引用
收藏
页码:632 / 641
页数:10
相关论文
共 50 条
  • [41] Reduced residual conduction gaps and favourable outcome in contact force-guided circumferential pulmonary vein isolation
    Itoh, Taihei
    Kimura, Masaomi
    Tomita, Hirofumi
    Sasaki, Shingo
    Owada, Shingen
    Horiuchi, Daisuke
    Sasaki, Kenichi
    Ishida, Yuji
    Kinjo, Takahiko
    Okumura, Ken
    EUROPACE, 2016, 18 (04): : 531 - 537
  • [42] Impact of Contact Force Monitoring in Acute Pulmonary Vein Isolation Using an Anatomic Approach. A Randomized Study
    Pedrote, Alonso
    Arana-Rueda, Eduardo
    Arce-Leon, Alvaro
    Acosta, Juan
    Gomez-Pulido, Federico
    Luis Martos-Maine, Jose
    Frutos-Lopez, Manuel
    Sanchez-Brotons, Juan
    Garcia-Riesco, Lorena
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2016, 39 (04): : 361 - 369
  • [43] Simultaneous pace-ablate during CARTO-guided pulmonary vein isolation with a contact-force sensing radiofrequency ablation catheter
    Chirag R. Barbhaiya
    Anthony Aizer
    Robert Knotts
    Scott Bernstein
    David Park
    Douglas Holmes
    Larry A. Chinitz
    Journal of Interventional Cardiac Electrophysiology, 2019, 54 : 119 - 124
  • [44] Prophylactic pulmonary vein isolation during isthmus ablation for atrial flutter: The PReVENT AF Study I
    Steinberg, Jonathan S.
    Romanov, Alexander
    Musat, Dan
    Preminger, Mark
    Bayramova, Sevda
    Artyomenko, Sergey
    Shabanov, Vitaliy
    Losik, Denis
    Karaskov, Alexander
    Shaw, Richard E.
    Pokushalov, Evgeny
    HEART RHYTHM, 2014, 11 (09) : 1567 - 1572
  • [45] Mechanisms of Pulmonary Vein Reconnection After Radiofrequency Ablation of Atrial Fibrillation: The Deterministic Role of Contact Force and Interlesion Distance
    Park, Chan-Il
    Lehrmann, Heiko
    Keyl, Cornelius
    Weber, Reinhold
    Schiebeling, Jochen
    Allgeier, Juergen
    Schurr, Patrick
    Shah, Ashok
    Neumann, Franz-Josef
    Arentz, Thomas
    Jadidi, Amir S.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (07) : 701 - 708
  • [46] Pulmonary vein isolation using "contact force" ablation: The effect on dormant conduction and long-term freedom from recurrent atrial fibrillation-A prospective study
    Andrade, Jason G.
    Monir, George
    Pollak, Scott J.
    Khairy, Paul
    Dubuc, Marc
    Roy, Denis
    Talajic, Mario
    Deyell, Marc
    Rivard, Lena
    Thibault, Bernard
    Guerra, Peter G.
    Nattel, Stanley
    Macle, Laurent
    HEART RHYTHM, 2014, 11 (11) : 1919 - 1924
  • [47] The contact force and continuity index parameters in pulmonary vein ablation
    Pietro, Turco
    EUROPACE, 2016, 18 (04): : 628 - 628
  • [48] Incidence and Anatomical Locations of Catheter Instability During Circumferential Pulmonary Vein Isolation Using Contact Force
    Makimoto, Hisaki
    Tilz, Roland Richard
    Lin, Tina
    Rillig, Andreas
    Mathew, Shibu
    Deiss, Sebastian
    Wissner, Erik
    Metzner, Andreas
    Rausch, Peter
    Bardyszewski, Alexander
    Zhang, Qingyong
    Kamioka, Masashi
    Lemes, Christine
    Kucx, Karl-Heinz
    Ouyang, Feifan
    INTERNATIONAL HEART JOURNAL, 2014, 55 (03) : 249 - 255
  • [49] Comparison of lesion formation between contact force-guided and non-guided circumferential pulmonary vein isolation: A prospective, randomized study
    Kimura, Masaomi
    Sasaki, Shingo
    Owada, Shingen
    Horiuchi, Daisuke
    Sasaki, Kenichi
    Itoh, Taihei
    Ishida, Yuji
    Kinjo, Takahiko
    Tomita, Hirofumi
    Okumura, Ken
    HEART RHYTHM, 2014, 11 (06) : 984 - 991
  • [50] Real-Time Contact Force Sensing for Pulmonary Vein Isolation in the Setting of Paroxysmal Atrial Fibrillation: Procedural and 1-Year Results
    Marijon, Eloi
    Fazaa, Samia
    Narayanan, Kumar
    Guy-Moyat, Benoit
    Bouzeman, Abdeslam
    Providencia, Rui
    Treguer, Frederic
    Combes, Nicolas
    Bortone, Agustin
    Boveda, Serge
    Combes, Stephane
    Albenque, Jean-paul
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (02) : 130 - 137