Evaluation of intracranial stenoses and aneurysms with accelerated 4D flow

被引:68
作者
Hope, Thomas A. [1 ]
Hope, Michael D. [1 ]
Purell, Derk D. [1 ]
von Morze, Cornelius [1 ]
Vigneron, Daniel B. [1 ]
Alley, Marcus T. [2 ]
Dillon, William P. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
Phase contrast; Velocity; Intracranial aneurysm; Intracranial stenosis; 4D Flow; PHASE-CONTRAST MR; VELOCITY-MEASUREMENTS; CEREBRAL ANEURYSMS; NATURAL-HISTORY; AORTIC ROOT; HEMODYNAMICS; VISUALIZATION; PATTERNS; 3D; RECONSTRUCTION;
D O I
10.1016/j.mri.2009.05.042
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to evaluate intracranial arterial stenoses and aneurysms with accelerated time-resolved three-dimensional (3D) phase-contrast MRI or 4D flow. The 4D flow technique was utilized to image four normal volunteers, two patients with intracranial stenoses and two patients with intracranial aneurysms. In order to reduce scan time, parallel imaging was combined with an acquisition strategy that eliminates the corners of k-space. In the two patients with intracranial stenoses, 4D flow velocity measurements showed that one patient had normal velocity profiles in agreement with a previous magnetic resonance angiogram (M RA), while the second showed increased velocities that indicated a less significant narrowing than suspected on a previous MRA, as confirmed by catheter angiography. This result may have prevented an invasive angiogram. In the two patients with 4-mm intracranial aneurysm, one had a stable helical flow pattern with a large jet, while the other had a temporally unstable flow pattern with a more focal jet possibly indicating that the second aneurysm may have a higher likelihood of rupture. Accelerated 4D flow provides time-resolved 3D velocity data in an 8- to 10-min scan. In the stenosis patients, the addition of 4D flow to a traditional M RA adds the velocity data provided from transcranial Doppler ultrasound (TCD) possibly allowing for more accurate grading of stenoses. In the aneurysm patients, visualization of flow patterns may help to provide prognostic information about future risk of rupture. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 50 条
  • [31] Intracardiac Flow at 4D CT: Comparison with 4D Flow MRI
    Lantz, Jonas
    Gupta, Vikas
    Henriksson, Lilian
    Karlsson, Matts
    Persson, Anders
    Carlhall, Carl-Johan
    Ebbers, Tino
    RADIOLOGY, 2018, 289 (01) : 51 - 58
  • [32] 4D flow MRI for intracranial hemodynamics assessment in Alzheimer's disease
    Rivera-Rivera, Leonardo A.
    Turski, Patrick
    Johnson, Kevin M.
    Hoffman, Carson
    Berman, Sara E.
    Kilgas, Phillip
    Rowley, Howard A.
    Carlsson, Cynthia M.
    Johnson, Sterling C.
    Wieben, Oliver
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2016, 36 (10) : 1718 - 1730
  • [33] Hemodynamic Parameters in the Parent Arteries of Unruptured Intracranial Aneurysms Depend on Aneurysm Size and Are Different Compared to Contralateral Arteries: A 7 Tesla 4D Flow MRI Study
    van Tuijl, Rick J.
    Timmins, Kimberley M.
    Velthuis, Birgitta K.
    van Ooij, Pim
    Zwanenburg, Jaco J. M.
    Ruigrok, Ynte M.
    van Der Schaaf, Irene C.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, : 223 - 230
  • [34] Accelerated sequences of 4D flow MRI using GRAPPA and compressed sensing: A comparison against conventional MRI and computational fluid dynamics
    Garreau, Morgane
    Puiseux, Thomas
    Toupin, Solenn
    Giese, Daniel
    Mendez, Simon
    Nicoud, Franck
    Moreno, Ramiro
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (06) : 2432 - 2446
  • [35] Flow diversion of fusiform intracranial aneurysms
    Griffin, Andrew
    Lerner, Emily
    Zuchowski, Adam
    Zomorodi, Ali
    Gonzalez, L. Fernando
    Hauck, Erik F.
    NEUROSURGICAL REVIEW, 2021, 44 (03) : 1471 - 1478
  • [36] 4D Flow with MRI
    Soulat, Gilles
    McCarthy, Patrick
    Markl, Michael
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, VOL 22, 2020, 22 : 103 - 126
  • [37] Accelerated 4D phase contrast MRI in skeletal muscle contraction
    Mazzoli, Valentina
    Gottwald, Lukas M.
    Peper, Eva S.
    Froeling, Martijn
    Coolen, Bram F.
    Verdonschot, Nico
    Sprengers, Andre M.
    van Ooij, Pim
    Strijkers, Gustav J.
    Nederveen, Aart J.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (05) : 1799 - 1811
  • [38] A multiscale computational modeling for cerebral blood flow with aneurysms and/or stenoses
    Yu, Hongtao
    Huang, George P.
    Yang, Zifeng
    Ludwig, Bryan R.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2018, 34 (10)
  • [39] Compressed-sensing accelerated 4D flow MRI of cerebrospinal fluid dynamics
    Jaeger, Elena
    Sonnabend, Kristina
    Schaarschmidt, Frank
    Maintz, David
    Weiss, Kilian
    Bunck, Alexander C.
    FLUIDS AND BARRIERS OF THE CNS, 2020, 17 (01)
  • [40] Association Between Flow Acceleration in the Carotid Artery and Intracranial Aneurysms
    Chang, Chun-Wei
    Wai, Yau-Yau
    Lim, Siew-Na
    Wu, Tony
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (05) : 1333 - 1340