Evaluation of intracranial stenoses and aneurysms with accelerated 4D flow

被引:68
作者
Hope, Thomas A. [1 ]
Hope, Michael D. [1 ]
Purell, Derk D. [1 ]
von Morze, Cornelius [1 ]
Vigneron, Daniel B. [1 ]
Alley, Marcus T. [2 ]
Dillon, William P. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
Phase contrast; Velocity; Intracranial aneurysm; Intracranial stenosis; 4D Flow; PHASE-CONTRAST MR; VELOCITY-MEASUREMENTS; CEREBRAL ANEURYSMS; NATURAL-HISTORY; AORTIC ROOT; HEMODYNAMICS; VISUALIZATION; PATTERNS; 3D; RECONSTRUCTION;
D O I
10.1016/j.mri.2009.05.042
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to evaluate intracranial arterial stenoses and aneurysms with accelerated time-resolved three-dimensional (3D) phase-contrast MRI or 4D flow. The 4D flow technique was utilized to image four normal volunteers, two patients with intracranial stenoses and two patients with intracranial aneurysms. In order to reduce scan time, parallel imaging was combined with an acquisition strategy that eliminates the corners of k-space. In the two patients with intracranial stenoses, 4D flow velocity measurements showed that one patient had normal velocity profiles in agreement with a previous magnetic resonance angiogram (M RA), while the second showed increased velocities that indicated a less significant narrowing than suspected on a previous MRA, as confirmed by catheter angiography. This result may have prevented an invasive angiogram. In the two patients with 4-mm intracranial aneurysm, one had a stable helical flow pattern with a large jet, while the other had a temporally unstable flow pattern with a more focal jet possibly indicating that the second aneurysm may have a higher likelihood of rupture. Accelerated 4D flow provides time-resolved 3D velocity data in an 8- to 10-min scan. In the stenosis patients, the addition of 4D flow to a traditional M RA adds the velocity data provided from transcranial Doppler ultrasound (TCD) possibly allowing for more accurate grading of stenoses. In the aneurysm patients, visualization of flow patterns may help to provide prognostic information about future risk of rupture. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 50 条
  • [21] Evaluation of Pulmonary Hypertension Using 4D Flow MRI
    Cerne, John W.
    Pathrose, Ashitha
    Gordon, Daniel Z.
    Sarnari, Roberto
    Veer, Manik
    Blaisdell, Julie
    Allen, Bradley D.
    Avery, Ryan
    Markl, Michael
    Ragin, Ann
    Carr, James C.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (01) : 234 - 245
  • [22] Characterization of Ascending Aortic Flow in Patients With Degenerative Aneurysms A 4D Flow Magnetic Resonance Study
    Ramaekers, Mitch J. F. G.
    Adriaans, Bouke P.
    Juffermans, Joe F.
    van Assen, Hans C.
    Bekkers, Sebastiaan C. A. M.
    Scholte, Arthur J. H. A.
    Kenjeres, Sasa
    Lamb, Hildo J.
    Wildberger, Joachim E.
    Westenberg, Jos J. M.
    Schalla, Simon
    INVESTIGATIVE RADIOLOGY, 2021, 56 (08) : 494 - 500
  • [23] Flow Diversion for Intracranial Aneurysms A Review
    D'Urso, Pietro I.
    Lanzino, Giuseppe
    Cloft, Harry J.
    Kallmes, David F.
    STROKE, 2011, 42 (08) : 2363 - 2368
  • [24] In VitroAssessment of Flow Variability in an Intracranial Aneurysm Model Using 4D Flow MRI and Tomographic PIV
    Medero, Rafael
    Ruedinger, Katrina
    Rutkowski, David
    Johnson, Kevin
    Roldan-Alzate, Alejandro
    ANNALS OF BIOMEDICAL ENGINEERING, 2020, 48 (10) : 2484 - 2493
  • [25] Intracranial aneurysm stiffness assessment using 4D Flow MRI
    Koizumi, Satoshi
    Kin, Taichi
    Sekine, Tetsuro
    Kiyofuji, Satoshi
    Umekawa, Motoyuki
    Saito, Nobuhito
    JOURNAL OF NEURORADIOLOGY, 2024, 51 (06)
  • [26] Clinical Evaluation of Aortic Coarctation With 4D Flow MR Imaging
    Hope, Michael D.
    Meadows, Alison K.
    Hope, Thomas A.
    Ordovas, Karen G.
    Saloner, David
    Reddy, Gautham P.
    Alley, Marcus T.
    Higgins, Charles B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) : 711 - 718
  • [27] Improved depiction of hemodynamics in intracranial aneurysms by 4D flow MRI at 7T compared to 3T
    P van Ooij
    R Kleinloog
    JJ Zwanenburg
    F Visser
    P Luijten
    AJ Barker
    M Markl
    A Nederveen
    CB Majoie
    L Regli
    G Rinkel
    B Verweij
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [28] Accelerated aortic 4D flow cardiovascular magnetic resonance using compressed sensing: applicability, validation and clinical integration
    Neuhaus, Elisabeth
    Weiss, Kilian
    Bastkowski, Rene
    Koopmann, Jonas
    Maintz, David
    Giese, Daniel
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2019, 21 (01)
  • [29] In Vitro Assessment of Flow Variability in an Intracranial Aneurysm Model Using 4D Flow MRI and Tomographic PIV
    Rafael Medero
    Katrina Falk
    David Rutkowski
    Kevin Johnson
    Alejandro Roldán-Alzate
    Annals of Biomedical Engineering, 2020, 48 : 2484 - 2493
  • [30] 4D flow imaging with MRI
    Stankovic, Zoran
    Allen, Bradley D.
    Garcia, Julio
    Jarvis, Kelly B.
    Markl, Michael
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2014, 4 (02) : 173 - 192