Comparison of Three Intraocular Lens Implantation Procedures for Aphakic Eyes With Insufficient Capsular Support: A Network Meta-analysis

被引:17
作者
Li, Xi [1 ]
Ni, Shuang [1 ]
Li, Shuyi [2 ]
Zheng, Qianyin [3 ]
Wu, Jing [1 ]
Liang, Guanlu [4 ]
Xu, Wen [1 ]
机构
[1] Zhejiang Univ, Affiliated Hosp 2, Eye Ctr, Coll Med, Hangzhou 310000, Zhejiang, Peoples R China
[2] Nanjing Med Univ, Hangzhou Peoples Hosp 1, Dept Ophthalmol, Hangzhou, Zhejiang, Peoples R China
[3] Taizhou Hosp, Dept Ophthalmol, Taizhou, Zhejiang, Peoples R China
[4] Zhejiang Hosp, Dept Ophthalmol, Hangzhou, Zhejiang, Peoples R China
关键词
RANDOMIZED CONTROLLED-TRIAL; CATARACT-SURGERY; FIXATION; OUTCOMES; SUTURE; INTERVENTIONS; DISLOCATION; ABSENCE; TRAUMA; IOL;
D O I
10.1016/j.ajo.2018.04.023
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the clinical outcomes and main complications of transscleral-fixated (TSF), intrascleral-fixated (ISF), and iris-fixated (IF) intraocular lenses (IOLs). DESIGN: Systematic review and network meta-analysis. METHODS: The authors searched PubMed, EMBASE, and the Cochrane Library for relevant articles up to April 2017 with no language restrictions, and related studies meeting the eligibility criteria were included. A Bayesian framework was applied to compare the visual outcomes and complications of these 3 approaches. RESULTS: A total of 14 studies with 845 eyes were included in the present report. There was no significant difference between any pair of surgical approaches in best-corrected visual acuity (BCVA) and in final BCVA achieving 20/40 or better (Snellen). ISF presented a lower risk of cystoid macular edema (CME) compared with TSF (risk ratio [RR], 0.45; 95% confidence interval [CI], [0.18, 1.0]). IF showed superiorities in less intraocular hemorrhage (IOH) than ISF (RR, 0.078; 95% CI [0.0095, 0.38]), as well as TSF (RR, 0.26; 95% CI, [0.09, 0.72]). IF had a lower risk of glaucoma escalation; the difference was slightly higher than the conventional level of significance (RR, 0.41; 95% CI, [0.16, 1.04]). Moreover, the surgical time in IF was shorter than TSF (standard mean difference [SMD], 2.98; 95% CI, [4.32, 1.64]) and ISF (SMD, 2.60; 95% CI, [3.71, 1.49]). However, IF was associated with a significantly higher risk of endothelial cell density (ECD) impairment (SMD, 0.54; 95% CI, [1.02, 0.05]) and significantly greater postoperative corneal endothelial cell loss rate (ECLR, %) (SMD, 0.35; 95% CI, [0.08, 0.63]) compared with TSF. CONCLUSIONS: Postoperative visual outcomes were comparable among TSF, ISF, and IF for eyes with insufficient capsular support. However, the risk of some complications differed among approaches. IF showed its superiorities in lower risk of IOH and glaucoma escalation as well as shorter surgical time, while IF was at a disadvantage in greater endothelial cell impairment. Since some patients might have a clear contraindication to one of the surgical approaches, the decision of surgical approach eventually depends on surgeon experience and the presenting pathology. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:10 / 19
页数:10
相关论文
共 37 条
[31]   Sutureless intrascleral intraocular lens implantation after ocular trauma [J].
Saleh, Maher ;
Heitz, Antoine ;
Bourcier, Tristan ;
Speeg, Claude ;
Delbosc, Bernard ;
Montard, Michel ;
Gaucher, David .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (01) :81-86
[32]   Long-term follow-up of primary anterior chamber intraocular lens implantation [J].
Sawada, T ;
Kimura, W ;
Kimura, T ;
Suga, H ;
Ohte, A ;
Yamanishi, S ;
Ohara, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (11) :1515-1520
[33]   Comparison of sutured versus sutureless scleral-fixated intraocular lenses [J].
Sindal, Manavi D. ;
Nakhwa, Chinmay P. ;
Sengupta, Sabyasachi .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (01) :27-34
[34]   Transscleral Suture-Fixated Versus Intrascleral Haptic-Fixated Intraocular Lens: A Comparative Study [J].
Sinha, Rajesh ;
Bansal, Mayank ;
Sharma, Namrata ;
Dada, Tanuj ;
Tandon, Radhika ;
Titiyal, Jeewan S. .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2017, 43 (06) :389-393
[35]   Comparison of Artisan iris-claw intraocular lens implantation and posterior chamber intraocular lens sulcus fixation for aphakic eyes [J].
Teng, He ;
Zhang, Hong .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2014, 7 (02) :283-287
[36]   Assessing the convergence of Markov Chain Monte Carlo methods: An example from evaluation of diagnostic tests in absence of a gold standard [J].
Toft, Nils ;
Innocent, Giles T. ;
Gettinby, George ;
Reid, Stuart W. J. .
PREVENTIVE VETERINARY MEDICINE, 2007, 79 (2-4) :244-256
[37]   Comparison of clinical outcomes between iris-fixated anterior chamber intraocular lenses and scleral-fixated posterior chamber intraocular lenses in Marfan syndrome with lens subluxation [J].
Zheng, Danying ;
Wan, Pengxia ;
Liang, Jingli ;
Song, Tingting ;
Liu, Yizhi .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 40 (03) :268-274