Monte Carlo validation of the irradiator parameters of the Portuguese gamma irradiation facility after its replenishment

被引:6
作者
Portugal, Luis [1 ]
Cardoso, Joao [1 ]
Oliveira, Carlos [1 ]
机构
[1] Inst Tecnol & Nucl, Unidade Proteccao & Seguranca Radiol, P-2686953 Sacavem, Portugal
关键词
Co-60 irradiation facility; Replenishment; Irradiator; MCNPX;
D O I
10.1016/j.apradiso.2009.09.028
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In December 2003 the irradiator of the Portuguese Co-60 irradiation facility. UTR, was replenished. Monte Carlo simulation studies were used to characterize the facility. Comparison of simulation results with experimental measurements were useful in estimating where the source elements were positioned and what the total activity was. For this purpose the MCNPX code was used. From the experimental point of view ionization chambers and PMMA dosemeters were used. The results indicate that the geometry of the irradiator used for simulation studies shows a shift on the vertical dimension relative to the actual geometry of approximately 8 cm. but with reduced influence on the irradiation process. Considering the uncertainties of the experimental and simulated approaches the activity of the irradiator stated by supplier has been confirmed. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:190 / 195
页数:6
相关论文
共 12 条
  • [1] UPGRADING OF A GAMMA-RADIATION FACILITY
    ANDRADE, ME
    COELHO, N
    OLIVEIRA, JE
    [J]. RADIATION PHYSICS AND CHEMISTRY, 1995, 46 (4-6): : 503 - 506
  • [2] [Anonymous], 2008, LACP071473
  • [3] BIJU K, 2008, P 15 INT M RAD PROC
  • [4] CAVACO MC, 1991, APPL RADIAT ISOTOPES, V42, P1185, DOI 10.1016/0883-2889(91)90194-6
  • [5] *GOLD SOFTW INC, 1999, SURF 7 US GUID
  • [6] MENDES CM, 2000, RADIAT PHYS CHEM, V35, P576
  • [7] Monte Carlo studies of the irradiator geometry of the Portuguese Gamma Irradiation Facility
    Oliveira, C
    Ferreira, LM
    Gonçalves, IF
    Salgado, J
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2002, 65 (03) : 293 - 295
  • [8] Isodose distributions and dose uniformity in the Portuguese gamma irradiation facility calculated using the MCNP code
    Oliveira, C
    Salgado, J
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 791 - 793
  • [9] Monte Carlo studies for irradiation process planning at the Portuguese gamma irradiation facility
    Oliveira, C
    Salgado, J
    Botelho, ML
    Ferreira, LM
    [J]. APPLIED RADIATION AND ISOTOPES, 2000, 53 (4-5) : 867 - 875
  • [10] Dose determination by Monte Carlo - a useful tool in gamma radiation process
    Oliveira, C
    Salgado, J
    Botelho, ML
    Ferreira, LM
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2000, 57 (3-6) : 667 - 670