Micromechanical Characterization of Intra-luminal Thrombus Tissue from Abdominal Aortic Aneurysms

被引:20
作者
Gasser, T. Christian [1 ]
Martufi, Giampaolo [1 ]
Auer, Martin [2 ]
Folkesson, Maggie [3 ]
Swedenborg, Jesper [3 ]
机构
[1] Royal Inst Technol, Dept Solid Mech, SE-10044 Stockholm, Sweden
[2] VASCOPS GmbH, A-8010 Graz, Austria
[3] Karolinska Univ Hosp, Karolinska Univ Hosp & Inst, Dept Vasc Surg, S-17176 Stockholm, Sweden
基金
瑞典研究理事会;
关键词
Intra-luminal thrombus; Abdominal Aortic Aneurysm (AAA); Finite element method (FEM); Microscale; Constitutive modeling; WALL; RUPTURE;
D O I
10.1007/s10439-009-9837-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The reliable assessment of Abdominal Aortic Aneurysm rupture risk is critically important in reducing related mortality without unnecessarily increasing the rate of elective repair. Intra-luminal thrombus (ILT) has multiple biomechanical and biochemical impacts on the underlying aneurysm wall and thrombus failure might be linked to aneurysm rupture. Histological slices from 7 ILTs were analyzed using a sequence of automatic image processing and feature analyzing steps. Derived microstructural data was used to define Representative Volume Elements (RVE), which in turn allowed the estimation of microscopic material properties using the non-linear Finite Element Method. ILT tissue exhibited complex microstructural arrangement with larger pores in the abluminal layer than in the luminal layer. The microstructure was isotropic in the abluminal layer, whereas pores started to orient along the circumferential direction towards the luminal site. ILT's macroscopic (reversible) deformability was supported by large pores in the microstructure and the inhomogeneous structure explains in part the radially changing macroscopic constitutive properties of ILT. Its microscopic properties decreased just slightly from the luminal to the abluminal layer. The present study provided novel microstructural and micromechanical data of ILT tissue, which is critically important to further explore the role of the ILT in aneurysm rupture. Data provided in this study allow an integration of structural information from medical imaging for example, to estimate ILT's macroscopic mechanical properties.
引用
收藏
页码:371 / 379
页数:9
相关论文
共 30 条
  • [1] Cellular content and permeability of intraluminal thrombus in abdominal aortic aneurysm
    Adolph, R
    Vorp, DA
    Steed, DL
    Webster, MW
    Kameneva, MV
    Watkins, SC
    [J]. JOURNAL OF VASCULAR SURGERY, 1997, 25 (05) : 916 - 926
  • [2] Abdominal aortic aneurysm: Rupture associated with the high-attenuating crescent sign
    Arita, T
    Matsunaga, N
    Takano, K
    Nagaoka, S
    Nakamura, H
    Katayama, S
    Zempo, N
    Esato, K
    [J]. RADIOLOGY, 1997, 204 (03) : 765 - 768
  • [3] Incidence and prevalence of abdominal aortic aneurysms, estimated by necropsy studies and population screening by ultrasound
    Bengtsson, H
    Sonesson, B
    Bergqvist, D
    [J]. ABDOMINAL AORTIC ANEURYSM: GENETICS, PATHOPHYSIOLOGY, AND MOLECULAR BIOLOGY, 1996, 800 : 1 - 24
  • [4] Hospital costs for elective endovascular and surgical repairs of infrarenal abdominal aortic aneurysms
    Bosch, JL
    Lester, JS
    McMahon, PM
    Beinfeld, MT
    Halpern, EF
    Kaufman, JA
    Brewster, DC
    Gazelle, GS
    [J]. RADIOLOGY, 2001, 220 (02) : 492 - 497
  • [5] Predicting local cell deformations in engineered tissue constructs: A multilevel finite element approach
    Breuls, RGM
    Sengers, BG
    Oomens, CWJ
    Bouten, CVC
    Baaijens, FPT
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (02): : 198 - 207
  • [6] A review of biological factors implicated in abdominal aortic aneurysm rupture
    Choke, E
    Cockerill, G
    Wilson, WRW
    Sayed, S
    Dawson, J
    Loftus, I
    Thompson, MM
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2005, 30 (03) : 227 - 244
  • [7] da Silva ES, 2000, CARDIOVASC SURG, V8, P526
  • [8] Biomechanics of abdominal aortic aneurysm in the presence of endoluminal thrombus: Experimental characterisation and structural static computational analysis
    Di Martino, E
    Mantero, S
    Inzoli, F
    Melissano, G
    Astore, D
    Chiesa, R
    Fumero, R
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 15 (04) : 290 - 299
  • [9] Failure properties of intraluminal thrombus in abdominal aortic aneurysm under static and pulsating mechanical loads
    Gasser, T. Christian
    Gorgulu, Goray
    Folkesson, Maggie
    Swedenborg, Jesper
    [J]. JOURNAL OF VASCULAR SURGERY, 2008, 48 (01) : 179 - 188
  • [10] GASSER TC, 2009, P WORLD C 2009 MED P