Embolization of aortic valve leaflet during valve-in-valve transcatheter aortic valve implantation: a case report

被引:2
作者
Kinthala, Sudhakar [1 ]
Saththasivam, Poovendran [1 ]
Ankam, Abistanand [1 ]
Sattur, Sudhakar [2 ]
机构
[1] Guthrie Robert Packer Hosp, Dept Anesthesiol, Sayre, PA 18840 USA
[2] Guthrie Robert Packer Hosp, Dept Cardiol, Sayre, PA 18840 USA
关键词
Aortic stenosis; Transcatheter aortic valve implantation; Valve leaflet avulsion; Embolization; Valve-in-valve; Vascular complications; Case report; COMPLICATIONS; AVULSION;
D O I
10.1093/ehjcr/ytaa010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Aortic stenosis (AS) is one of the most common valvular disorders worldwide. An increasing number of transcatheter aortic valve implantation (TAVI) procedures are being performed yearly for managing AS. This, along with the occurrence of common complications, makes timely diagnosis essential to manage rare complications and improve patient outcomes. Case summary We present a case of a 77-year-old Caucasian male with severe AS with a dysfunctional bioprosthetic valve following previous surgical valve replacement. During valve-in-valve TAVI, we noted bioprosthetic valve leaflet avulsion and embolization causing a major vascular occlusion that resulted in vascular insufficiency of the left lower extremity. This condition was managed successfully via immediate diagnosis using transoesophageal echocardiogram, angiogram, and vascular surgical intervention for retrieving the embolized valve to re-establish circulation. Discussion To our knowledge, this is the first case of aortic valve leaflet embolization during TAVI resulting in significant vascular insufficiency. Vascular complications are common during TAVI. However, not all vascular complications are the same. Our case highlights an embolic vascular complication from an avulsed prosthetic material during a challenging valve-in-valve TAVI procedure.
引用
收藏
页数:5
相关论文
共 11 条
[1]   Impact of Short-Term Complications on Mortality and Quality of Life After Transcatheter Aortic Valve Replacement [J].
Arnold, Suzanne V. ;
Zhang, Yiran ;
Baron, Suzanne J. ;
McAndrew, Thomas C. ;
Alu, Maria C. ;
Kodali, Susheel K. ;
Kapadia, Samir ;
Thourani, Vinod H. ;
Miller, Craig ;
Mack, Michael J. ;
Leon, Martin B. ;
Cohen, David J. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (04) :362-369
[2]   Trends in Complications and Outcomes of Patients Undergoing Transfemoral Transcatheter Aortic Valve Replacement Experience From the PARTNER Continued Access Registry [J].
Beohar, Nirat ;
Kirtane, Ajay J. ;
Blackstone, Eugene ;
Waksman, Ron ;
Holmes, David, Jr. ;
Minha, Sa'ar ;
Alli, Oluseun ;
Suri, Rakesh M. ;
Svensson, Lars G. ;
Leon, Martin ;
Kodali, Susheel .
JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (04) :355-363
[3]   Vascular Access Site Complications after Percutaneous Transfemoral Aortic Valve Implantation [J].
Kahlert, Philipp ;
Al-Rashid, Fadi ;
Weber, Marcel ;
Wendt, Daniel ;
Heine, Torsten ;
Kottenberg, Eva ;
Thielmann, Matthias ;
Kuehl, Hilmar ;
Peters, Juergen ;
Jakob, Heinz G. ;
Sack, Stefan ;
Erbel, Raimund ;
Eggebrecht, Holger .
HERZ, 2009, 34 (05) :398-408
[4]   Guidelines Update on Indications for Transcatheter Aortic Valve Replacement [J].
Nishimura, Rick A. ;
O'Gara, Patrick T. ;
Bonow, Robert O. .
JAMA CARDIOLOGY, 2017, 2 (09) :1036-1037
[5]   Burden of valvular heart diseases: a population-based study [J].
Nkomo, Vuyisile T. ;
Gardin, Julius M. ;
Skelton, Thomas N. ;
Gottdiener, John S. ;
Scott, Christopher G. ;
Enriquez-Sarano, Maurice .
LANCET, 2006, 368 (9540) :1005-1011
[6]   Avulsion of Aortic Leaflet During Transcatheter Aortic Valve Replacement [J].
Patankar, Gautam R. ;
Grayburn, Paul A. ;
Hebeler, Robert F., Jr. ;
Henry, Albert C. ;
Stoler, Robert C. .
JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2016, 29 (05) :549-551
[7]   Delayed Management of Partial Aortic Valve Avulsion After Transcatheter Aortic Valve Replacement [J].
Sherev, Dimitri ;
Azizi, Khalid ;
Azimi, Nassir A. ;
Van Nordheim, Susan ;
Moreno-Cabral, Ricardo .
ANNALS OF THORACIC SURGERY, 2017, 104 (01) :E17-E18
[8]  
Smith T., 2016, J Cardiol Curr Res, V5, P00148, DOI [10.15406/jccr.2015.05.00148, DOI 10.15406/JCCR.2015.05.00148]
[9]   Thirty-Day Results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry A European Registry of Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Valve [J].
Thomas, Martyn ;
Schymik, Gerhard ;
Walther, Thomas ;
Himbert, Dominique ;
Lefevre, Thierry ;
Treede, Hendrik ;
Eggebrecht, Holger ;
Rubino, Paolo ;
Michev, Iassen ;
Lange, Ruediger ;
Anderson, William N. ;
Wendler, Olaf .
CIRCULATION, 2010, 122 (01) :62-U130
[10]   Comparison of local versus general anesthesia in patients undergoing transcatheter aortic valve replacement: A meta-analysis [J].
Villablanca, Pedro A. ;
Mohananey, Divyanshu ;
Nikolic, Katarina ;
Bangalore, Sripal ;
Slovut, David P. ;
Mathew, Verghese ;
Thourani, Vinod H. ;
Rode's-Cabau, Josep ;
Nunez-Gil, Ivan J. ;
Shah, Tina ;
Gupta, Tanush ;
Briceno, David F. ;
Garcia, Mario J. ;
Gutsche, Jacob T. ;
Augoustides, John G. ;
Ramakrishna, Harish .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 91 (02) :330-342