Transcatheter aortic valve implantation with the 34 mm self-expanding CoreValve Evolut R: initial experience in 101 patients from a multicentre registry

被引:14
作者
Kuhn, Christian [1 ,2 ]
Frerker, Christian [3 ]
Meyer, Anne-Kathrin [1 ]
Kurz, Thomas [4 ]
Schaefer, Ulrich [5 ]
Deuschl, Florian [5 ]
Abdel-Wahab, Mohamed [6 ]
Schewel, Dimitry [3 ]
Elghalban, Ahmed [6 ]
Kuck, Karl-Heinz [3 ]
Frey, Norbert [1 ,2 ]
Frank, Derk [1 ,2 ]
机构
[1] UKSH, Dept Internal Med Cardiol 3, Angiol, Intens Care, Campus Kiel,Arnold Heller Str 3,Bldg 6, D-24105 Kiel, Germany
[2] Partner Site Hamburg Kiel Lubeck, DZHK German Ctr Cardiovasc Res, Kiel, Germany
[3] Asklepios St Georg, Dept Cardiol, Hamburg, Germany
[4] UKSH, Dept Internal Med Cardiol 2, Angiol, Intens Care, Lubeck, Germany
[5] Univ Heart Ctr Hamburg, Dept Cardiol, Hamburg, Germany
[6] Segeberger Kliniken GmbH, Ctr Heart, Bad Segeberg, Germany
关键词
aortic stenosis; degenerative valve; TAVI; CLINICAL-OUTCOMES; REPLACEMENT; BIOPROSTHESIS; STENOSIS;
D O I
10.4244/EIJ-D-17-01153
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The recently released Medtronic CoreValve Evolut R 34 mm is the largest self-expanding transcatheter heart valve ever developed. Clinical data for this device size are scarce. We therefore aimed to evaluate the clinical performance and safety of the new device. Methods and results: We report on the first 101 consecutive patients treated with transfemoral transcatheter aortic valve implantation (TAVI) using the 34 mm Evolut R device in a multicentre registry. Clinical parameters were determined before the procedure and echocardiography was performed at baseline and discharge. VARC-2 criteria were assessed at 30 days. Mean age was 80.7 years; mean logistic EuroSCORE was 19.8%. Procedural duration was 71.6 min. Echocardiography at discharge revealed a mean AVA of 2.0 cm(2), moderate aortic regurgitation (AR) in 4.0% and severe AR in 1.0%. VARC-2 device success was achieved in 92.1%, while the early safety endpoint occurred in 11 patients (10.9%). New permanent pacemakers were implanted in 17 patients (18.7%). Thirty-day mortality was 2.0%, a stroke occurred in 3.0%, with a disabling stroke in one patient. The incidence of major vascular complications and bleeding was 1.0% and 5.0%, respectively. Conclusions: Initial experience with the new self-expanding CoreValve Evolut R 34 mm valve is characterised by high procedural success, good haemodynamic performance and a low early complication rate.
引用
收藏
页码:301 / 305
页数:5
相关论文
共 12 条
[1]   Comparison of Balloon-Expandable vs Self-expandable Valves in Patients Undergoing Transcatheter Aortic Valve Replacement The CHOICE Randomized Clinical Trial [J].
Abdel-Wahab, Mohamed ;
Mehilli, Julinda ;
Frerker, Christian ;
Neumann, Franz-Josef ;
Kurz, Thomas ;
Toelg, Ralph ;
Zachow, Dirk ;
Guerra, Elena ;
Massberg, Steffen ;
Schaefer, Ulrich ;
El-Mawardy, Mohamed ;
Richardt, Gert .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 311 (15) :1503-1514
[2]   A systematic review on the safety of second-generation transcatheter aortic valves [J].
Athappan, Ganesh ;
Gajulapalli, Rama D. ;
Tuzcu, Murat E. ;
Svensson, Lars G. ;
Kapadia, Samir R. .
EUROINTERVENTION, 2016, 11 (09) :1034-1043
[3]   Impact of low-profile sheaths on vascular complications during transfemoral transcatheter aortic valve replacement [J].
Barbanti, Marco ;
Binder, Ronald K. ;
Freeman, Melanie ;
Wood, David A. ;
Leipsic, Jonathon ;
Cheung, Anson ;
Ye, Jian ;
Tan, John ;
Toggweiler, Stefan ;
Yang, Tae-Hyun ;
Dvir, Danny ;
Maryniak, Kasia ;
Lauck, Sandra ;
Webb, John G. .
EUROINTERVENTION, 2013, 9 (08) :929-935
[4]  
Baumgartner H, 2018, EUR HEART J, V39, P1980, DOI [10.1093/eurheartj/ehx636, 10.1093/eurheartj/ehx391]
[5]   Clinical Outcomes With a Repositionable Self-Expanding Transcatheter Aortic Valve Prosthesis The International FORWARD Study [J].
Grube, Eberhard ;
Van Mieghem, Nicolas M. ;
Bleiziffer, Sabine ;
Modine, Thomas ;
Bosmans, Johan ;
Manoharan, Ganesh ;
Linke, Axel ;
Scholtz, Werner ;
Tchetche, Didier ;
Finkelstein, Ariel ;
Trillo, Ramiro ;
Fiorina, Claudia ;
Walton, Antony ;
Malkin, Christopher J. ;
Oh, Jae K. ;
Qiao, Hongyan ;
Windecker, Stephan .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (07) :845-853
[6]   Multicenter Comparison of Novel Self-Expanding Versus Balloon-Expandable Transcatheter Heart Valves [J].
Husser, Oliver ;
Kim, Won-Keun ;
Pellegrini, Costanza ;
Holzamer, Andreas ;
Walther, Thomas ;
Mayr, Patrick N. ;
Joner, Michael ;
Kasel, Albert M. ;
Trenkwalder, Teresa ;
Michel, Jonathan ;
Rheude, Tobias ;
Kastrati, Adnan ;
Schunkert, Heribert ;
Burgdorf, Christof ;
Hilker, Michael ;
Moellmann, Helge ;
Hengstenberg, Christian .
JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (20) :2078-2087
[7]   Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document [J].
Kappetein, A. Pieter ;
Head, Stuart J. ;
Genereux, Philippe ;
Piazza, Nicolo ;
van Mieghem, Nicolas M. ;
Blackstone, Eugene H. ;
Brott, Thomas G. ;
Cohen, David J. ;
Cutlip, Donald E. ;
van Es, Gerrit-Anne ;
Hahn, Rebecca T. ;
Kirtane, Ajay J. ;
Krucoff, Mitchell W. ;
Kodali, Susheel ;
Mack, Michael J. ;
Mehran, Roxana ;
Rodes-Cabau, Josep ;
Vranckx, Pascal ;
Webb, John G. ;
Windecker, Stephan ;
Serruys, Patrick W. ;
Leon, Martin B. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (01) :6-23
[8]   Treatment of Symptomatic Severe Aortic Stenosis With a Novel Resheathable Supra-Annular Self-Expanding Transcatheter Aortic Valve System [J].
Manoharan, Ganesh ;
Walton, Antony S. ;
Brecker, Stephen J. ;
Pasupati, Sanjeevan ;
Blackman, Daniel J. ;
Qiao, Hongyan ;
Meredith, Ian T. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (10) :1359-1367
[9]   Procedural Results with the Self-Expanding 31 mm CoreValve Aortic Bioprosthesis in Patients with Large Annuli [J].
Murray, Marie-Isabel ;
Geis, Nicolas ;
Pleger, Sven T. ;
Katus, Hugo A. ;
Bekeredjian, Raffi ;
Chorianopoulos, Emmanuel .
JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2014, 27 (02) :191-198
[10]   Early Clinical Outcomes After Transcatheter Aortic Valve Replacement Using a Novel Self-Expanding Bioprosthesis in Patients With Severe Aortic Stenosis Who Are Suboptimal for Surgery Results of the Evolut R US Study [J].
Popma, Jeffrey J. ;
Reardon, Michael J. ;
Khabbaz, Kamal ;
Harrison, J. Kevin ;
Hughes, G. Chad ;
Kodali, Susheel ;
George, Isaac ;
Deeb, G. Michael ;
Chetcuti, Stan ;
Kipperman, Robert ;
Brown, John ;
Qiao, Hongyan ;
Slater, James ;
Williams, Mathew R. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (03) :268-275