Synthesis and characterization of grafted thermosensitive hydrogels for heating activated controlled release

被引:75
作者
Ankareddi, Induvadana [1 ]
Brazel, Christopher S. [1 ]
机构
[1] Univ Alabama, Dept Biol & Chem Engn, Tuscaloosa, AL 35487 USA
关键词
negative thermosensitivity; N-isopropylacylamide; grafted system; positive thermal response;
D O I
10.1016/j.ijpharm.2006.11.065
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Poly(N-isopropylacrylamide), PNIPAAm, hydrogels are negatively thermosensitive which means that they have an expanded hydrogel structure at low temperatures and a shrunken structure at high temperatures. Based on this negative thermosensitivity of PNIPAAm, a drug delivery system with PNIPAAm oligomers grafted onto poly(hydroxyethyl methacrylate) PHEMA, a thermally nonresponsive polymer was designed. Poly(hydroxyethyl methacrylate-g-N-isopropylacrylamide), P(HEMA-g-NIPAAm) hydrogels were synthesized to control the release of an imbedded drug. This new grafted system exhibited high diffusivity at temperatures greater than the lower critical solution temperature (LCST) of the PNIPAAm oligomers. Utilizing PNIPAAm's LCST of approximately 34 degrees C, the release rate was controlled by the temperature of the release medium. The LCST of PNIPAAm was tuned by making copolymers with hydrophobic butyl methacrylate (BMA). Theophylline and inulin release profiles were studied using PHEMA, PNIPAAm and P(HEMA-g-NIPAAm) at three temperatures with drug diffusion coefficients determined as a function of temperature and drug type. The molecular weights between crosslinks and mesh sizes of PHEMA hydrogels were calculated using Flory-Rehner and rubber-elasticity theories. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:241 / 247
页数:7
相关论文
共 19 条
[11]   EFFECT OF COMONOMER HYDROPHILICITY AND IONIZATION ON THE LOWER CRITICAL SOLUTION TEMPERATURE OF N-ISOPROPYLACRYLAMIDE COPOLYMERS [J].
FEIL, H ;
BAE, YH ;
FEIJEN, J ;
KIM, SW .
MACROMOLECULES, 1993, 26 (10) :2496-2500
[12]  
Flory P J., PRINCIPLES POLYM CHE
[13]   pH/temperature-responsive behaviors of semi-IPN and comb-type graft hydrogels composed of alginate and poly (N-isopropylacrylamide) [J].
Ju, HK ;
Kim, SY ;
Lee, YM .
POLYMER, 2001, 42 (16) :6851-6857
[14]   Pulsatile drug release control using hydrogels [J].
Kikuchi, A ;
Okano, T .
ADVANCED DRUG DELIVERY REVIEWS, 2002, 54 (01) :53-77
[15]   Responsive polymeric delivery systems [J].
Kost, J ;
Langer, R .
ADVANCED DRUG DELIVERY REVIEWS, 2001, 46 (1-3) :125-148
[16]  
OKUYAMA Y, 1993, J BIOMAT SCI-POLYM E, V4, P545, DOI 10.1163/156856293X00771
[17]   Responsive and recognitive hydrogels using star polymers [J].
Oral, E ;
Peppas, NA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2004, 68A (03) :439-447
[18]  
PAPPENHEIMER JR, 1951, AM J PHYSIOL, V167, P13, DOI 10.1152/ajplegacy.1951.167.1.13
[19]   Stimuli-responsive polymers in gene delivery [J].
Piskin, E .
EXPERT REVIEW OF MEDICAL DEVICES, 2005, 2 (04) :501-509