Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al2O3 Nanofluid

被引:33
|
作者
Ju, Yongfeng [1 ]
Zhu, Tiezhu [1 ]
Mashayekhi, Ramin [2 ]
Mohammed, Hayder, I [3 ]
Khan, Afrasyab [4 ]
Talebizadehsardari, Pouyan [5 ]
Yaici, Wahiba [6 ]
机构
[1] Huaiyin Inst Technol, Fac Elect Informat Engn, Huaian 223003, Peoples R China
[2] Islamic Azad Univ, Khomeinishahr Branch, Young Researchers & Elite Club, Khomeinishahr 11984175, Iran
[3] Univ Garmian, Coll Educ, Dept Phys, Kurdistan 46021, Kalar, Iraq
[4] South Ural State Univ, Inst Engn & Technol, Dept Hydraul & Hydraul & Pneumat Syst, Lenin Prospect 76, Chelyabinsk 454080, Russia
[5] Brunel Univ London, Ctr Sustainable Energy Use Food Chains, Inst Energy Futures, Kingston Lane, Uxbridge UB8 3PH, Middx, England
[6] Nat Resources Canada, CanmetENERGY Res Ctr, 1 Haanel Dr, Ottawa, ON K1A 1M1, Canada
关键词
twisted tape inserts; nanofluid; performance evaluation criterion; heat exchanger pipe; Nusselt number; friction factor; PARABOLIC SOLAR COLLECTOR; QUANTITY LUBRICATION; PERFORMANCE-CHARACTERISTICS; TRANSFER ENHANCEMENT; FORCED-CONVECTION; ENERGY DEMAND; WATER-HEATER; FLOW; TUBES; EFFICIENCY;
D O I
10.3390/nano11061570
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The hydrothermal performance of multiple semi-twisted tape inserts inside a heat exchanger pipe is numerically examined in three-dimensions. This study aims to find the optimum case for having the highest heat transfer enhancement with the lowest friction factor using nanofluid (Al2O3/water). A performance evaluation criterion (PEC) is defined to characterize the performance based on both friction factor and heat transfer. It was found that increasing the number of semi-twisted tapes increases the number of swirl flow streams and leads to an enhancement in the local Nusselt number as well as the friction factor. The average Nusselt number increases from 15.13 to 28.42 and the average friction factor enhances from 0.022 to 0.052 by increasing the number of the semi-twisted tapes from 0 to 4 for the Reynolds number of 1000 for the base fluid. By using four semi-twisted tapes, the average Nusselt number increases from 12.5 to 28.5, while the friction factor reduces from 0.155 to 0.052 when the Reynolds number increases from 250 to 1000 for the base fluid. For the Reynolds number of 1000, the increase in nanofluid concentration from 0 to 3% improves the average Nusselt number and friction factor by 6.41% and 2.29%, respectively. The highest PEC is equal to 1.66 and belongs to the Reynolds number of 750 using four semi-twisted tape inserts with 3% nanoparticles. This work offers instructions to model an advanced design of twisted tape integrated with tubes using multiple semi-twisted tapes, which helps to provide a higher amount of energy demand for solar applications.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] Numerical investigation of shell and tube heat exchanger using Al2O3 nanofluid
    Surana A.K.
    Samuel K.J.
    Harshit S.
    Kumar U.
    Raj R.T.K.
    Raj, R. Thundil Karuppa (thundilr@gmail.com), 1600, International Journal of Thermodynamics (20): : 59 - 68
  • [42] Performance prediction and evaluation of heat pipe with hexagonal perforated twisted tape inserts
    Kadbhane, Snehal Vasant
    Pangavhane, Dilip R.
    HEAT AND MASS TRANSFER, 2024, 60 (06) : 987 - 1008
  • [43] Experimental Investigation on the Heat Pipe using Al2O3 and CuO Hybrid Nanofluid
    Hariprasad Tarigonda
    Dadamiah P. M. D. Shaik
    D. Raghu Rami Reddy
    G. Vidya Sagar Reddy
    International Journal of Thermophysics, 2022, 43
  • [44] Experimental Investigation on the Heat Pipe using Al2O3 and CuO Hybrid Nanofluid
    Tarigonda, Hariprasad
    Shaik, Dadamiah P. M. D.
    Reddy, D. Raghu Rami
    Reddy, G. Vidya Sagar
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2022, 43 (10)
  • [45] Influence of the typical twisted tape inserts into the inner tube of double-pipe heat exchanger: A limited review
    Kadhim, Saif Ali
    Hammoodi, Karrar A.
    Ali, Hayder Mohsin
    Rashid, Farhan Lafta
    Togun, Hussein
    Alsayah, Ahmed Mohsin
    Hussein, Ahmed Kadhim
    Abd, Hussain Saad
    Omle, Issa
    RESULTS IN ENGINEERING, 2025, 25
  • [46] Numerical study of turbulent nanofluid heat transfer in a tubular heat exchanger with twin twisted-tape inserts
    Rahim Hosseinnezhad
    Omid Ali Akbari
    Hamid Hassanzadeh Afrouzi
    Mohit Biglarian
    Ali Koveiti
    Davood Toghraie
    Journal of Thermal Analysis and Calorimetry, 2018, 132 : 741 - 759
  • [47] Improving hydrothermal performance of double-tube heat exchanger with modified twisted tape inserts using hybrid nanofluid
    Sumit Kr. Singh
    Jahar Sarkar
    Journal of Thermal Analysis and Calorimetry, 2021, 143 : 4287 - 4298
  • [48] CFD Modeling of Laminar Flow and Heat Transfer Utilizing Al2O3/Water Nanofluid in a Finned-Tube with Twisted Tape
    Habeeb, Laith J.
    Saleh, Fouad A.
    Maajel, Bassim M.
    FME TRANSACTIONS, 2019, 47 (01): : 89 - 100
  • [49] Experimental and Numerical Study of Heat Transfer in Double-Pipe Heat Exchanger Using Al2O3, and TiO2 Water Nanofluid
    Mund, Abhishek
    Pattanayak, Bikash
    Jayakumar, J. S.
    Parashar, Kajal
    Parashar, S. K. S.
    ADVANCES IN FLUID AND THERMAL ENGINEERING, 2019, : 531 - 540
  • [50] Effect of γ-Al2O3/Water Nanofluid on Heat Transfer and Pressure Drop Characteristics of Shell and Coil Heat Exchanger With Different Coil Curvatures
    Salem, M. R.
    Ali, R. K.
    Sakr, R. Y.
    Elshazly, K. M.
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2015, 7 (04)