Evaluation of Multiple Semi-Twisted Tape Inserts in a Heat Exchanger Pipe Using Al2O3 Nanofluid

被引:33
|
作者
Ju, Yongfeng [1 ]
Zhu, Tiezhu [1 ]
Mashayekhi, Ramin [2 ]
Mohammed, Hayder, I [3 ]
Khan, Afrasyab [4 ]
Talebizadehsardari, Pouyan [5 ]
Yaici, Wahiba [6 ]
机构
[1] Huaiyin Inst Technol, Fac Elect Informat Engn, Huaian 223003, Peoples R China
[2] Islamic Azad Univ, Khomeinishahr Branch, Young Researchers & Elite Club, Khomeinishahr 11984175, Iran
[3] Univ Garmian, Coll Educ, Dept Phys, Kurdistan 46021, Kalar, Iraq
[4] South Ural State Univ, Inst Engn & Technol, Dept Hydraul & Hydraul & Pneumat Syst, Lenin Prospect 76, Chelyabinsk 454080, Russia
[5] Brunel Univ London, Ctr Sustainable Energy Use Food Chains, Inst Energy Futures, Kingston Lane, Uxbridge UB8 3PH, Middx, England
[6] Nat Resources Canada, CanmetENERGY Res Ctr, 1 Haanel Dr, Ottawa, ON K1A 1M1, Canada
关键词
twisted tape inserts; nanofluid; performance evaluation criterion; heat exchanger pipe; Nusselt number; friction factor; PARABOLIC SOLAR COLLECTOR; QUANTITY LUBRICATION; PERFORMANCE-CHARACTERISTICS; TRANSFER ENHANCEMENT; FORCED-CONVECTION; ENERGY DEMAND; WATER-HEATER; FLOW; TUBES; EFFICIENCY;
D O I
10.3390/nano11061570
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The hydrothermal performance of multiple semi-twisted tape inserts inside a heat exchanger pipe is numerically examined in three-dimensions. This study aims to find the optimum case for having the highest heat transfer enhancement with the lowest friction factor using nanofluid (Al2O3/water). A performance evaluation criterion (PEC) is defined to characterize the performance based on both friction factor and heat transfer. It was found that increasing the number of semi-twisted tapes increases the number of swirl flow streams and leads to an enhancement in the local Nusselt number as well as the friction factor. The average Nusselt number increases from 15.13 to 28.42 and the average friction factor enhances from 0.022 to 0.052 by increasing the number of the semi-twisted tapes from 0 to 4 for the Reynolds number of 1000 for the base fluid. By using four semi-twisted tapes, the average Nusselt number increases from 12.5 to 28.5, while the friction factor reduces from 0.155 to 0.052 when the Reynolds number increases from 250 to 1000 for the base fluid. For the Reynolds number of 1000, the increase in nanofluid concentration from 0 to 3% improves the average Nusselt number and friction factor by 6.41% and 2.29%, respectively. The highest PEC is equal to 1.66 and belongs to the Reynolds number of 750 using four semi-twisted tape inserts with 3% nanoparticles. This work offers instructions to model an advanced design of twisted tape integrated with tubes using multiple semi-twisted tapes, which helps to provide a higher amount of energy demand for solar applications.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Enhancing heat transfer in a double-tube heat exchanger using perforated twisted tape and nanofluid
    Marzouk, S. A.
    Aljabr, Ahmad
    Almehmadi, Fahad Awjah
    Sharaf, Maisa A.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2025,
  • [32] TiO2/water Nanofluid Heat Transfer in Heat Exchanger Equipped with Double Twisted-Tape Inserts
    Eiamsa-ard, S.
    Ketrain, R.
    Chuwattanakul, V.
    INTERNATIONAL CONFERENCE ON NANOMATERIALS AND BIOMATERIALS (ICNB 2017), 2018, 350
  • [33] Thermal performance of screen mesh heat pipe with Al2O3 nanofluid
    Ghanbarpour, M.
    Nikkam, N.
    Khodabandeh, R.
    Toprak, M. S.
    Muhammed, M.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2015, 66 : 213 - 220
  • [34] Heat transfer through heat exchanger using Al2O3 nanofluid at different concentrations
    Albadr, Jaafar
    Tayal, Satinder
    Alasadi, Mushtaq
    CASE STUDIES IN THERMAL ENGINEERING, 2013, 1 (01) : 38 - 44
  • [35] LAMINAR CONVECTIVE HEAT TRANSFER AND FRICTION FACTOR OF AL(2)O(3) NANOFLUID IN CIRCULAR TUBE FITTED WITH TWISTED TAPE INSERTS
    Sundar, L. Syam
    Sharma, K. V.
    INTERNATIONAL JOURNAL OF AUTOMOTIVE AND MECHANICAL ENGINEERING, 2011, 3 : 265 - 278
  • [36] Optimizing the thermal performance of a double-pipe heat exchanger using twisted tapes with variable cuts and Fe3O4 nanofluid
    Varma, K. P. V. Krishna
    Naveen, N. S.
    Kishore, P. S.
    Pujari, Satish
    Jogi, Krishna
    Raju, V. Dhana
    JOURNAL OF THERMAL ENGINEERING, 2024, 10 (05): : 1184 - 1197
  • [37] Influence of W-cut twisted tape inserts on heat transfer characteristics of a counter flow heat exchanger using CeO2 nanofluid - an experimental and numerical investigations
    Reddy, Goda Sreenivasulu
    Kalaivanan, Ramasamy
    Kumar, Rampelli Uday
    Jadhav, Prakash H.
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2024,
  • [38] HEAT TRANSFER ENHANCEMENT IN A HELICALLY COILED CONVERGENT AND DIVERGENT TUBE HEAT EXCHANGER WITH Al2O3 NANOFLUID
    Shankar, Nandhakumar
    Perumalsamy, Sethusundaram Parambakkattur
    Karur, Mohanraj Chandran
    THERMAL SCIENCE, 2023, 27 (6A): : 4707 - 4718
  • [39] Heat transfer enhancement in double pipe heat exchanger: exploring twisted tape inserts with dimple configuration
    Heeraman, Jatoth
    Sandeep, Chinta
    Chaurasiya, Prem Kumar
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (16) : 8839 - 8856
  • [40] Effect of Al2O3/water nanofluid on heat transfer of turbulent flow in the inner pipe of a double-pipe heat exchanger
    Zheng, Mingrui
    Han, Dong
    Asif, Faizan
    Si, Zetian
    HEAT AND MASS TRANSFER, 2020, 56 (04) : 1127 - 1140