Feasibility and effectiveness of percutaneous balloon mitral valvuloplasty under echocardiographic guidance only

被引:10
作者
Liu, Yao
Guo, Gai-Li
Wen, Bin
Wang, Shouzheng
Ou-Yang, Wen-Bin
Xie, Yongquan
Pan, Xiang-Bin [1 ,2 ]
机构
[1] Fuwai Hosp, Chinese Acad Med Sci, Beijing, Peoples R China
[2] Peking Union Med Coll, Beijing, Peoples R China
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 2018年 / 35卷 / 10期
关键词
echocardiography; mitral stenosis; mitral valvuloplasty; percutaneous intervention; VALVULAR HEART-DISEASE; STENOSIS; VALVOTOMY;
D O I
10.1111/echo.14055
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectivePercutaneous balloon mitral valvuloplasty (PBMV) is the treatment of choice in patients with isolated mitral stenosis. This study aimed to assess the feasibility of PBMV under echocardiography guidance only of isolated mitral stenosis (MS). MethodsFrom October 2016 to Dec 2017, 20 consecutive patients with severe MS underwent PBMV with echocardiography as the only imaging modality at a single center. Outpatient follow-up including chest radiography, electrocardiography, and transthoracic echocardiography was conducted at 1, 3,6, and 12months after the procedure. ResultsAll 20 patients successfully underwent PBMV under echocardiography guidance without radiation and contrast agent. Among them, 2 patients were pregnant, 5 had chronic renal failure, and 1 had history of allergy to contrast. Mitral transvalvular pressure gradient measured at catheterization dropped from 13.352.85mmHg to 5.10 +/- 1.17mmHg (P<.01). Mitral valve area increased from 0.82 +/- 0.10cm(2) pre-PBMV to 1.88 +/- 0.24cm(2) post-PBMV (P<.01). Mean balloon diameter was 26.63 +/- 0.93mm. Mild mitral regurgitation developed in 6 patients. Mean follow-up duration was 6.27 +/- 3.12months. At last follow-up, mitral valve area remained high (1.71 +/- 0.14cm(2)) and mean transmitral pressure gradient low (6.07 +/- 1.03mmHg). No pericardial effusion or peripheral vascular complications occurred. ConclusionIn this small experience, PBMV could be successfully performed under only echocardiography guidance and appeared safe and effective while avoiding radiation and contrast agent use.
引用
收藏
页码:1507 / 1511
页数:5
相关论文
共 19 条
  • [1] IMMEDIATE AND LONG-TERM RESULTS OF BALLOON AND SURGICAL CLOSED MITRAL VALVOTOMY - A RANDOMIZED COMPARATIVE-STUDY
    ARORA, R
    NAIR, M
    KALRA, GS
    NIGAM, M
    KHALILULLAH, M
    [J]. AMERICAN HEART JOURNAL, 1993, 125 (04) : 1091 - 1094
  • [2] Risk of cancer associated with cardiac catheterization procedures during childhood: a cohort study in France
    Baysson, Helene
    Rehel, Jean Luc
    Boudjemline, Younes
    Petit, Jerome
    Girodon, Brigitte
    Aubert, Bernard
    Laurier, Dominique
    Bonnet, Damien
    Bernier, Marie-Odile
    [J]. BMC PUBLIC HEALTH, 2013, 13
  • [3] Chen CR, 1998, CATHETER CARDIO DIAG, V43, P132, DOI 10.1002/(SICI)1097-0304(199802)43:2<132::AID-CCD5>3.0.CO
  • [4] 2-B
  • [5] Repeat Percutaneous Mitral Balloon Valvuloplasty for Patients with Mitral Valve Restenosis
    Chmielak, Zbigniew
    Klopotowski, Mariusz
    Kruk, Mariusz
    Demkow, Marcin
    Konka, Marek
    Chojnowska, Lidia
    Hoffman, Piotr
    Witkowski, Adam
    Ruzyllo, Witold
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (07) : 986 - 992
  • [6] Valvular heart disease and pregnancy - Part I: Native valves
    Elkayam, U
    Bitar, F
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (02) : 223 - 230
  • [7] Fawzy ME, 1996, CATHETER CARDIO DIAG, V38, P9
  • [8] USE OF TWO-DIMENSIONAL ECHOCARDIOGRAPHY DURING TRANS-SEPTAL CARDIAC-CATHETERIZATION
    KRONZON, I
    GLASSMAN, E
    COHEN, M
    WINER, H
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (02) : 425 - 428
  • [9] Liu Y, 2017, Zhonghua Yi Xue Za Zhi, V97, P1222, DOI 10.3760/cma.j.issn.0376-2491.2017.16.008
  • [10] Maoqin Shu, 2005, Eur J Intern Med, V16, P413, DOI 10.1016/j.ejim.2005.02.012