Using the fringe field of a clinical MRI scanner enables robotic navigation of tethered instruments in deeper vascular regions

被引:67
作者
Azizi, Arash [1 ]
Tremblay, Charles C. [1 ]
Gagne, Kevin [1 ]
Martel, Sylvain [1 ]
机构
[1] Polytech Montreal, Inst Biomed Engn, Dept Comp & Software Engn, Nanorobot Lab, Montreal, PQ, Canada
关键词
MAGNETIC NAVIGATION; TECHNOLOGY; SYSTEM; STEERABILITY;
D O I
10.1126/scirobotics.aax7342
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Navigating tethered instruments through the vasculatures to reach deeper physiological locations presently inaccessible would extend the applicability of many medical interventions, including but not limited to local diagnostics, imaging, and therapies. Navigation through narrower vessels requires minimizing the diameter of the instrument, resulting in a decrease of its stiffness until steerability becomes unpractical, while pushing the instrument at the insertion site to counteract the friction forces from the vessel walls caused by the bending of the instrument. To reach beyond the limit of using a pushing force alone, we report a method relying on a complementary directional pulling force at the tip created by gradients resulting from the magnetic fringe field emanating outside a clinical magnetic resonance imaging (MRI) scanner. The pulling force resulting from gradients exceeding 2 tesla per meter in a space that supports human-scale interventions allows the use of smaller magnets, such as the deformable spring as described here, at the tip of the instrument. Directional forces are achieved by robotically positioning the patient at predetermined successive locations inside the fringe field, a method that we refer to as fringe field navigation (FFN). We show through in vitro and in vivo experiments that x-ray-guided FFN could navigate microguidewires through complex vasculatures well beyond the limit of manual procedures and existing magnetic platforms. Our approach facilitated miniaturization of the instrument by replacing the torque from a relatively weak magnetic field with a configuration designed to exploit the superconducting magnet-based directional forces available in clinical MRI rooms.
引用
收藏
页数:12
相关论文
共 45 条
  • [1] Modeling magnetic torque and force for controlled manipulation of soft-magnetic bodies
    Abbott, Jake J.
    Ergeneman, Olgac
    Kummer, Michael P.
    Hirt, Ann M.
    Nelson, Bradley J.
    [J]. IEEE TRANSACTIONS ON ROBOTICS, 2007, 23 (06) : 1247 - 1252
  • [2] Interventional oncology in multidisciplinary cancer treatment in the 21st century
    Adam, Andreas
    Kenny, Lizbeth M.
    [J]. NATURE REVIEWS CLINICAL ONCOLOGY, 2015, 12 (02) : 105 - 113
  • [3] Wearing lead aprons in surgical operating rooms: ergonomic injuries evidenced by infrared thermography
    Alexandre, Dominique
    Prieto, Marc
    Beaumont, Fabien
    Taiar, Redha
    Polidori, Guillaume
    [J]. JOURNAL OF SURGICAL RESEARCH, 2017, 209 : 227 - 233
  • [4] Steerable Catheters in Cardiology: Classifying Steerability and Assessing Future Challenges
    Ali, Awaz
    Plettenburg, Dick H.
    Breedveld, Paul
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (04) : 679 - 693
  • [5] [Anonymous], HDB ENDOVASCULAR PER
  • [6] [Anonymous], IEEE REV BIOMED ENG
  • [7] [Anonymous], LANCET
  • [8] Clinical applications of robotic technology in vascular and endovascular surgery
    Antoniou, George A.
    Riga, Celia V.
    Mayer, Erik K.
    Cheshire, Nicholas J. W.
    Bicknell, Colin D.
    [J]. JOURNAL OF VASCULAR SURGERY, 2011, 53 (02) : 493 - 499
  • [9] Aziz A., 2017, Irrelevant Advertising: How More Consumer Tracking Can Make Ads Less Effective, P1
  • [10] Azizi Arash, 2016, 2016 IEEE International Conference on Automation Science and Engineering (CASE), P567, DOI 10.1109/COASE.2016.7743454