Trace elements in fine and coarse particles emitted from coal-fired power plants with different air pollution control systems

被引:21
作者
Oetari, Poerna Sri [1 ]
Hadi, Sudharto P. [1 ]
Huboyo, Haryono Setiyo [2 ]
机构
[1] Diponegoro Univ, Sch Postgrad Studies, Doctoral Program Environm Sci, Semarang, Indonesia
[2] Diponegoro Univ, Fac Engn, Dept Environm Engn, Semarang, Indonesia
关键词
Air pollution; Emission; Fine and coarse particle; Coal-fired power plant; Trace elements; PARTICULATE MATTER; ATMOSPHERIC EMISSIONS; SOURCE APPORTIONMENT; SOURCE PROFILES; URBAN; PM10; PB; HG; DESULFURIZATION; SPECIATION;
D O I
10.1016/j.jenvman.2019.109497
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Emissions from coal-fired power plants (CFPP) are one of the major sources of air pollutants in the industrial sector. We characterized the metal element mass concentration in fine and coarse particles from CFPP using sub-bituminous coal. We sampled stack emissions from six CFPP units equipped with different emission control technologies. The power plants were located in Jepara Regency (using electrostatic precipitator (ESP) alone or in combination, as ESP-flue gas desulfurization, FGD) and in Rembang Regency (using ESP alone). We measured PM2.5 and PM10 particle emissions using the US EPA 201 A method and further subjected the particles to laboratory analysis for trace metal elements using inductively coupled plasma-mass spectrometry (ICPMS). The CFPP emissions showed that the mass concentration of coarse particles was higher than that of fine particles. Based on metal element analysis only, the total mass in fine particles was higher than that in the coarse particles. With respect to the metal elements detected, the major elements, minor elements, and trace elements, on average, represented 7%, 15%, and 77%, respectively. In this study, we identified new trace elements associated with coal combustion, namely Na, Be, and Sn. The emission factor in fine particles is not significant for different air pollution control The element marker of coal fired-power plant should consider installed air pollution control.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Abdurrahman S., 2016, IND EN OUTL
  • [2] [Anonymous], 2016, World Energy Outlook - Spec. Rep, P266, DOI [DOI 10.1021/AC00256A010, 10.1021/ac00256a010]
  • [3] [Anonymous], 2014, ENV IMPACT ASSESSMEN
  • [4] Geochemistry and petrology of selected coal samples from Sumatra, Kalimantan, Sulawesi, and Papua, Indonesia
    Belkin, Harvey E.
    Tewalt, Susan J.
    Hower, James C.
    Stucker, J. D.
    O'Keefe, J. M. K.
    [J]. INTERNATIONAL JOURNAL OF COAL GEOLOGY, 2009, 77 (3-4) : 260 - 268
  • [5] Air pollution and health
    Brunekreef, B
    Holgate, ST
    [J]. LANCET, 2002, 360 (9341) : 1233 - 1242
  • [6] Clarke B.L., 1992, Trace elements - emissions from coal combustion and gasification
  • [7] Emission characteristics of Cd, Pb and Mn from coal combustion: Field study at coal-fired power plants in China
    Deng, Shuang
    Shi, Yingjie
    Liu, Yu
    Zhang, Chen
    Wang, Xiangfeng
    Cao, Qing
    Li, Songgeng
    Zhang, Fan
    [J]. FUEL PROCESSING TECHNOLOGY, 2014, 126 : 469 - 475
  • [8] Engelbrecht JP., 2002, ENVIRON SCI POLICY, V5, P157, DOI [10.1016/S1462-9011(02)00029-1, DOI 10.1016/S1462-9011(02)00029-1]
  • [9] EPA U, 2017, METH 201A DET PM 10
  • [10] EPA U., 1999, DET MET AMB PART MAT