Simple and Efficient Compressed Sensing Encoder for Wireless Body Area Network

被引:49
作者
Ravelomanantsoa, Andrianiaina [1 ]
Rabah, Hassan [1 ]
Rouane, Amar [1 ]
机构
[1] Univ Lorraine, Inst Jean Lamour, F-54000 Nancy, France
关键词
Compressed sensing (CS) encoder; electrocardiogram (ECG); electroencephalogram (EEG); energy; heterogenous system; SPICE; sub-Nyquist measurement; SystemC-AMS; wireless body area network (WBAN); DESIGN; ANALOG; IMPLEMENTATION; CONVERTER; ACCURATE;
D O I
10.1109/TIM.2014.2320393
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Compressed sensing (CS) is an emerging signal processing technique that enables sub-Nyquist measurement of signals having sparse representations in certain bases. Since most physiological signals treated within a wireless body area network (WBAN) are sparse, CS can be applied to WBANs to reduce the number of measurements and minimize the energy consumption of the sensor nodes. In this paper, we propose a simple and efficient CS encoder device used to measure signals within sensor nodes of a WBAN. A digital and an analog models of the proposed CS encoder are presented. As the CS encoder and decoder are tightly coupled, a model of the overall acquisition chain is required in the first stages of development and validation. To do this, we propose a virtual prototyping of the system with SystemC-AMS. A SPICE model and a hardware prototype of the proposed CS encoder are also presented. The simulation results of both models show that the proposed encoder was able to compressively measure an electrocardiogram (ECG) and an electroencephalogram signals with compression ratios of 6: 1 and 4: 1, respectively, which save 82.9% and 75% of the energy consumption of transceivers. The experiment results were consistent with those of the model and show that the hardware prototype was able to compressively measure an ECG signal with a compression ratio of 8: 1. Comparison with a random demodulator (RD) was carried out and shows that the proposed encoder outperformed RD in terms of compression ratio and reconstruction quality.
引用
收藏
页码:2973 / 2982
页数:10
相关论文
共 28 条
[1]   RTSP: An Accurate and Energy-Efficient Protocol for Clock Synchronization in WSNs [J].
Akhlaq, Muhammad ;
Sheltami, Tarek R. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (03) :578-589
[2]  
Ambat SK, 2012, EUR SIGNAL PR CONF, P1434
[3]  
Angrisani L, 2013, IEEE IMTC P, P102
[4]  
[Anonymous], 2014, P INT C HLTH INF, DOI DOI 10.1007/978-3-319-03005-0_
[5]  
[Anonymous], P DES AUT TEST EUR C
[6]  
[Anonymous], ABS12062197 CORR
[7]  
Balouchestani M, 2012, MIDWEST SYMP CIRCUIT, P916, DOI 10.1109/MWSCAS.2012.6292170
[8]   NESTA: A Fast and Accurate First-Order Method for Sparse Recovery [J].
Becker, Stephen ;
Bobin, Jerome ;
Candes, Emmanuel J. .
SIAM JOURNAL ON IMAGING SCIENCES, 2011, 4 (01) :1-39
[9]  
Bonavolontà F, 2013, IEEE IMTC P, P126
[10]   Robust uncertainty principles:: Exact signal reconstruction from highly incomplete frequency information [J].
Candès, EJ ;
Romberg, J ;
Tao, T .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (02) :489-509