Continued Rise in Rates of Cardiovascular Implantable Electronic Device Infections in the United States: Temporal Trends and Causative Insights

被引:307
作者
Voigt, Andrew
Shalaby, Alaa [2 ]
Saba, Samir [1 ]
机构
[1] Univ Pittsburgh, Cardiovasc Inst, Sect Cardiovasc Electrophysiol, Pittsburgh, PA 15213 USA
[2] Pittsburgh VA Hlth Care Syst, Pittsburgh, PA USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2010年 / 33卷 / 04期
关键词
cardiovascular implantable electronic devices; infection; causes; population study; CARDIAC-RESYNCHRONIZATION THERAPY; CHRONIC HEART-FAILURE; CARDIOVERTER-DEFIBRILLATOR; MEDICARE BENEFICIARIES; PERMANENT PACEMAKER; MANAGEMENT; SYSTEM;
D O I
10.1111/j.1540-8159.2009.02569.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Methods: We analyzed the occurrence of CIED infections and the associated changes in characteristics of CIED recipients, using the National Hospital Discharge Survey database from 1996 through 2006. Results: The number of CIED implantations continued to increase after 2003 from 199,516 in 2004 to 222,940 in 2006, representing a 12% increment. In the same period, the number of CIED infections increased from 8,273 in 2004 to 12,979 in 2006, representing a 57% increment. From 1996 to 2006, comorbid illnesses in recipients of new CIED devices became more prevalent with an increasing percentage of patients with end-organ failures (6.5% in 1996 vs 8.0% in 2006, P < 0.001) and diabetes mellitus (14.5% in 1996 vs 16.5% in 2006, P = 0.005). The proportion of Caucasian recipients also decreased (65.6% in 1996 vs 57.6% in 2006, P < 0.001). During that same period, the number of implanted cardiac resynchronization devices increased dramatically while the age of CIED recipients did not change. Conclusion: The number of patients with CIED-related infections in the United States continues to increase out of proportion to the increase in implantation rates. Possible causes for this on-going epidemic include sicker patients with varying racial backgrounds, and more complex procedures. These insights may help improve our ability to best select patients for CIED implantation in "real-life" settings. (PACE 2010; 414-419).
引用
收藏
页码:414 / 419
页数:6
相关论文
共 22 条
[1]   Cardiac resynchronization in chronic heart failure [J].
Abraham, WT ;
Fisher, WG ;
Smith, AL ;
Delurgio, DB ;
Leon, AR ;
Loh, E ;
Kocovic, DZ ;
Packer, M ;
Clavell, AL ;
Hayes, DL ;
Ellestad, M ;
Messenger, J ;
Trupp, RJ ;
Underwood, J ;
Pickering, F ;
Truex, C ;
McAtee, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) :1845-1853
[2]   The relation between patients' outcomes and the volume of cardioverter-defibrillator implantation procedures performed by physicians treating medicare beneficiaries [J].
Al-Khatib, SM ;
Lucas, FL ;
Jollis, JG ;
Malenka, DJ ;
Wennberg, DE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (08) :1536-1540
[3]   Nonvalvular cardiovascular device-related infections [J].
Baddour, LM ;
Bettmann, MA ;
Bolger, AF ;
Epstein, AE ;
Ferrieri, P ;
Gerber, MA ;
Gewitz, MH ;
Jacobs, AK ;
Levison, ME ;
Newburger, JW ;
Pallasch, TJ ;
Wilson, WR ;
Baltimore, RS ;
Falace, DA ;
Shulman, ST ;
Tani, LY ;
Taubert, KA .
CIRCULATION, 2003, 108 (16) :2015-2031
[4]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[5]   Renal insufficiency and the risk of infection from pacemaker or defibrillator surgery [J].
Bloom, H ;
Heeke, B ;
Leon, A ;
Mera, F ;
Delurgio, D ;
Beshai, J ;
Langberg, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (02) :142-145
[6]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[7]   Increasing rates of cardiac device infections among Medicare beneficiaries: 1990-1999 [J].
Cabell, CH ;
Heidenreich, PA ;
Chu, VH ;
Moore, CM ;
Stryjewski, ME ;
Corey, GR ;
Fowler, VG .
AMERICAN HEART JOURNAL, 2004, 147 (04) :582-586
[8]   Diagnosis and management of infections involving implantable electrophysiologic cardiac devices [J].
Chua, JD ;
Wilkoff, BL ;
Lee, I ;
Juratli, N ;
Longworth, DL ;
Gordon, SM .
ANNALS OF INTERNAL MEDICINE, 2000, 133 (08) :604-608
[9]   The effect of cardiac resynchronization on morbidity and mortality in heart failure [J].
Cleland, JGF ;
Daubert, J ;
Erdmann, E ;
Freemantle, N ;
Gras, D ;
Kappenberger, L ;
Tavazzi, L ;
Cleland, JGF ;
Daubert, JC ;
Erdmann, E ;
Gras, D ;
Kappenberger, L ;
Klein, W ;
Tavazzi, L ;
Poole-Wilson, PA ;
Rydén, L ;
Wedel, H ;
Wellens, HJJ ;
Uretsky, B ;
Thygesen, K ;
Böcker, D ;
Marijianowski, MMH ;
Freemantle, N ;
Calvert, MJ ;
Christ, G ;
Fruhwald, F ;
Hofmann, R ;
Krypta, A ;
Leisch, F ;
Pacher, R ;
Rauscha, F ;
Tavernier, R ;
Thomsen, PEB ;
Boesgaard, S ;
Eiskjær, H ;
Esperen, GT ;
Haarbo, J ;
Hagemann, A ;
Korup, E ;
Moller, M ;
Mortensen, P ;
Sogaard, P ;
Vesterlund, T ;
Huikuri, H ;
Niemelä, KI ;
Toivonen, L ;
Bauer, F ;
Cohen-Solal, A ;
Crocq, C ;
Djiane, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (15) :1539-1549
[10]   Current concepts - Treatment of infections associated with surgical implants [J].