Modeling and calculation of open carbon dioxide refrigeration system

被引:3
作者
Cai, Yufei [1 ]
Zhu, Chunling [1 ]
Jiang, Yanlong [1 ]
Shi, Hong [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Aerosp Engn, Nanjing 210016, Jiangsu, Peoples R China
关键词
Carbon dioxide; Open refrigeration system; Refrigeration capacity loss; Supercritical state; Two-phase region; PERFORMANCE;
D O I
10.1016/j.enconman.2014.09.061
中图分类号
O414.1 [热力学];
学科分类号
摘要
Based on the analysis of the properties of carbon dioxide, an open carbon dioxide refrigeration system is proposed, which is responsible for the situation without external electricity unit. A model of open refrigeration system is developed, and the relationship between the storage environment of carbon dioxide and refrigeration capacity is conducted. Meanwhile, a test platform is developed to simulation the performance of the open carbon dioxide refrigeration system. By comparing the theoretical calculations and the experimental results, several conclusions are obtained as follows: refrigeration capacity loss by heat transfer in supercritical state is much more than that in two-phase region and the refrigeration capacity loss by remaining carbon dioxide has little relation to the state of carbon dioxide. The results will be helpful to the use of open carbon dioxide refrigeration. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:92 / 98
页数:7
相关论文
共 19 条
[1]  
[Anonymous], 2012, A Heat Transfer Textbook
[2]  
Cai Yufei, 2011, Journal of Nanjing University of Aeronautics & Astronautics, V43, P551
[3]   Design and experimental analysis of a carbon dioxide transcritical chiller for commercial refrigeration [J].
Cecchinato, Luca ;
Chiarello, Manuel ;
Corradi, Marco .
APPLIED ENERGY, 2010, 87 (06) :2095-2101
[4]   Performance of cascade cycles working with blends of CO2 + natural refrigerants [J].
Di Nicola, Giovanni ;
Polonara, Fabio ;
Stryjek, Roman ;
Arteconi, Alessia .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (06) :1436-1445
[5]   Optimal analysis of gas cooler and intercooler for two-stage CO2 trans-critical refrigeration system [J].
Li, Wenhua .
ENERGY CONVERSION AND MANAGEMENT, 2013, 71 :1-11
[6]   Performance evaluation and optimal configuration analysis of a CO2/NH3 cascade refrigeration system with falling film evaporator-condenser [J].
Ma, Ming ;
Yu, Jianlin ;
Wang, Xiao .
ENERGY CONVERSION AND MANAGEMENT, 2014, 79 :224-231
[7]  
Ordóñez JA, 2000, J SCI FOOD AGR, V80, P1831, DOI 10.1002/1097-0010(200010)80:13<1831::AID-JSFA707>3.0.CO
[8]  
2-Z
[9]   Carbon dioxide - new uses for an old refrigerant [J].
Pearson, A .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (08) :1140-1148
[10]   Thermoeconomic optimization and exergy analysis of CO2/NH3 cascade refrigeration systems [J].
Rezayan, Omid ;
Behbahaninia, Ali .
ENERGY, 2011, 36 (02) :888-895