Assessing the internal standardization of the direct multi-element determination in beer samples through microwave-induced plasma optical emission spectrometry

被引:13
作者
Pires, Lais N. [1 ]
Dias, Fabio de S. [2 ]
Teixeira, Leonardo Sg [1 ,3 ]
机构
[1] Univ Fed Bahia, Inst Quim, Dept Quim Analit, Campus Univ Ondina, BR-40170115 Salvador, BA, Brazil
[2] Univ Fed Reconcavo Bahia, Ctr Ciencias Exatas & Tecnol, Campus Univ Cruz das Almas, BR-44380000 Cruz Das Almas, BA, Brazil
[3] Univ Fed Bahia, INCT Energia & Ambiente, Campus Univ Ondina, BR-40170115 Salvador, BA, Brazil
关键词
Microwave induced plasma optical emission spectrometry; Internal standardization; Beer; Multi-element determination; HYDRIDE-FORMING ELEMENTS; TRACE-ELEMENTS; ATOMIC SPECTROMETRY; DILUTION ANALYSIS; ALCOHOLIC BEVERAGES; INTRODUCTION SYSTEM; PRECIOUS METALS; MIP-OES; CU; PB;
D O I
10.1016/j.aca.2019.09.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An evaluation of different elements (Be, Ga, In, Sc, and Y) as internal standards was performed to determine the content of Al, Ba, Co, Cr, Cu, Fe, Mn, Ni, Sr, Zn, Ca, Mg, Na, K in beer samples through microwave induced plasma optical emission spectrometry. The analytes were determined after simple dilutions of the samples with a 1.0 M nitric acid solution at a 1:4 ratio (sample: acid solution) with the addition of the IS. The analytical performance for each potential IS was established based on the limit of detection, limit of quantification, addition and recovery tests and accuracy obtained in the determination of each analyte. Each analyte responded differently when internal standardization was applied, and as such, the evaluation of each IS is important in the development of the method. In the presence of the recommended internal standard, the limit of detection varied, in mu g L-1, from 0.23 to 4.6 for the microelements and between 10 and 620 for the macroelements. The limit of quantification, in mu g L-1, was between 0.78 and 15.4 and between 30 and 970 for the microelements and macroelements, respectively. The precisions of the measurements, expressed as the relative standard deviation (n = 10; 0.50 and 3.0 mg L-1 of each analyte), were lower than 1.0% for all analytes. The proposed method was applied for the multi-element determination in commercial beer samples and the results were compared with those obtained by inductively coupled plasma optical emission spectrometry after sample digestion. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 70 条
  • [1] Multiresidue Determination and Uncertainty Analysis of Pesticides in Soil by Ultrafast Liquid Chromatography Coupled to Mass Spectrometry
    Ahumada, Diego A.
    Arias, Luis A.
    Bojaca, Carlos R.
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2013, 24 (07) : 1188 - +
  • [2] Multivariate characterisation of beers according to their mineral content
    Alcázar, A
    Pablos, F
    Martín, MJ
    González, AG
    [J]. TALANTA, 2002, 57 (01) : 45 - 52
  • [3] Recognition of the geographical origin of beer based on support vector machines applied to chemical descriptors
    Alcazar, Angela
    Marcos Jurado, Jose
    Palacios-Morillo, Ana
    de Pablos, Fernando
    Jesus Martin, Maria
    [J]. FOOD CONTROL, 2012, 23 (01) : 258 - 262
  • [4] DETERMINATION OF MICRO AND TRACE ELEMENTS OF COMMERCIAL BEERS
    Alexa, Lorand
    Kantor, Andrea
    Kovacs, Bela
    Czipa, Nikolett
    [J]. JOURNAL OF MICROBIOLOGY BIOTECHNOLOGY AND FOOD SCIENCES, 2018, 7 (04): : 432 - 436
  • [5] Microwave-Induced Plasma Optical Emission Spectrometry (MIP OES) and Standard Dilution Analysis to Determine Trace Elements in Pharmaceutical Samples
    Althoff, Amanda G.
    Williams, Charles B.
    McSweeney, Tina
    Goncalves, Daniel A.
    Donati, George L.
    [J]. APPLIED SPECTROSCOPY, 2017, 71 (12) : 2692 - 2698
  • [6] Evaluation of internal standardization for the determination of semivolatile analytes in difficult matrices by simultaneous multielement atomic absorption spectrometry
    Barkonikos, Konstantinos
    Pasias, Ioannis N.
    Thomaidis, Nikolaos S.
    [J]. TALANTA, 2014, 129 : 165 - 170
  • [7] Aerosol dilution as a simple strategy for analysis of complex samples by ICP-MS
    Barros, Ariane I.
    Pinheiro, Fernanda C.
    Amaral, Clarice D. B.
    Lorencatto, Rodolfo
    Nobrega, Joaquim A.
    [J]. TALANTA, 2018, 178 : 805 - 810
  • [8] Baxter E. D., 2001, BEER QUALITY SAFETY
  • [9] Bechlin MA, 2015, J BRAZIL CHEM SOC, V26, P1879
  • [10] Bismuth as a general internal standard for lead in atomic absorption spectrometry
    Bechlin, Marcos A.
    Fortunato, Felipe M.
    Ferreira, Edilene C.
    Gomes Neto, Jose A.
    Nobrega, Joaquim A.
    Donati, George L.
    Jones, Bradley T.
    [J]. ANALYTICA CHIMICA ACTA, 2014, 831 : 24 - 30