Evaluation of the burst characteristics for axial notches on SG tubings

被引:6
作者
Hwang, SS [1 ]
Kim, HP [1 ]
Kim, JS [1 ]
机构
[1] Korea Atom Energy Res Inst, Taejon 305353, South Korea
关键词
D O I
10.1016/j.nucengdes.2004.06.003
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Some events of steam generator tubes have been reported in some nuclear power plants around the world. Main causes of the leakage are from various types of corrosion in the steam generator (SG) tubing. Primary water stress corrosion cracking (PWSCC) of steam generator tubing have occurred in many tubes in Korean plants, and they were repaired using sleeves or plugs. In order to develop proper repair criteria, it is necessary to ascertain the leak behavior of the tubings. A high-pressure leak and burst testing system was manufactured. Various types of electro-discharged-machined (EDM) notches having different lengths were machined on the o.d. of test tubes to study SG tube behavior. Leak rate and ligament rupture pressure as well as the burst pressure were measured for the tubes at room temperature. Rupture pressure of the part through-wall defect tubes depends on the defect depth and length. Water flow rates after the rupture were independent of the flaw types; tubes having 20-60 mm long EDM notches showed similar flow rates regardless of the initial defect depth. A fast pressurization rate generated a lower burst pressure than the case of a slow pressurization. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:139 / 143
页数:5
相关论文
共 6 条
  • [1] BENSON J, 1999, TE106365R14 EPRI
  • [2] Cochet B, 1991, NP6865L EPRI, V1
  • [3] Kasza K., 2002, NUREGCR6789
  • [4] Keating R. F., 2001, 1006252 EPRI
  • [5] Kim J.S, 2003, DESTRUCTIVE ANAL PUL
  • [6] MacDonald P.E., 1996, NUREG/CR-6365, DOI [10.2172/236258, DOI 10.2172/236258]