Minimally invasive percutaneous plate osteosynthesis (MIPPO) using the DCS in proximal and distal femoral fractures

被引:0
|
作者
Krettek, C [1 ]
Schandelmaier, P [1 ]
Miclau, T [1 ]
Tscherne, H [1 ]
机构
[1] Hannover Med Sch, Trauma Dept, D-30623 Hannover, Germany
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 1997年 / 28卷
关键词
minimally invasive; percutaneous plate osteosynthesis; subtrochanteric femur fracture; supracondylar femoral fracture; MIPPO;
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
In a prospective study, 14 cases of supracondylar or subtrochanteric fractures or osteotomies were stabilized with a dynamic condylar screw (DCS) inserted using a minimally invasive percutaneous plate osteosynthesis (MIPPO) technique, The technique con:ted of 4 major steps: Ij placement Of the guide wire under fluoroscopic control and condylar screw insertion through a stab incision; 2) plate insertion beneath the vastus lateral muscle; 3) engagement of the condylar screw to the plate using a modified T-handle and, 4) plate fixation to the shaft using percutaneously inserted self-cutting screws, Between October 1994 and December 1995, 14 cases in 12 patients met the inclusion criteria. There were 11 acute fractures (6 subtrochanteric, 5 supracondylar) and 3 corrective osteotomies. Nine fractures were closed, and 2 were open. One 97-year-old patient died 6 weeks after trauma. There were no infections and 12 of 13 cases healed without a second procedure. There was I implant failure (plate screw breakage), which required repeat fracture fixation. At follow-up, there were 2 varus deformities above 5 degrees, 2 shortenings over 20 mm, and I rotational deformity of 20 degrees. According to the Neer score, there were 6 excellent, 1 satisfactory, 3 unsatisfactory results and no failures. The results of this technique compare favourably with those of other series of osteosynthesis of subtrochanteric or supracondylar femoral fractures treated with internal fixation without the added morbidity associated with an extensive approach or autogenous bone grafting. However, the surgical technique is demanding, and care must be taken to restore the axial alignment.
引用
收藏
页码:SA20 / SA30
页数:11
相关论文
共 50 条
  • [1] Minimizing radiation and incision in minimally invasive percutaneous plate osteosynthesis (MIPPO) of distal tibial fractures
    Rijal L.
    Sagar G.
    Mani K.
    Joshi K.N.
    Joshi A.
    European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (3) : 361 - 365
  • [2] Minimally Invasive Plate Osteosynthesis for Distal Tibia Fractures
    Lai, Ted C.
    Fleming, Justin J.
    CLINICS IN PODIATRIC MEDICINE AND SURGERY, 2018, 35 (02) : 223 - +
  • [3] Treatment of Proximal Humeral Fractures Using Minimally Invasive Plate Osteosynthesis
    Ebrahimpour, Adel
    Zandi, Reza
    Sajjadi, Mohammadreza Minator
    Sadighi, Mehrdad
    Karimi, Amin
    Okhovatpour, Mohammad Ali
    Moradi, Pejman
    TRAUMA MONTHLY, 2018, 23 (06)
  • [4] Minimal invasive percutaneous plate osteosynthesis (MIPPO) in humeral shaft fractures
    Kundakci, Bugra
    Bicer, Omer Sunkar
    Huri, Gazi
    Tekin, Mustafa
    Bagir, Melih
    Deveci, M. Ali
    Mirioglu, Akif
    CUKUROVA MEDICAL JOURNAL, 2022, 47 (02): : 555 - 562
  • [5] Limited Open Reduction and Percutaneous Plate Osteosynthesis Alternative Option to Minimally Invasive Plate Osteosynthesis in Management of Distal Tibia Fractures
    Sah, Shambhu
    Bikash, K. C.
    Dangi, Sailoj Jung
    Rai, Rem Kumar
    Yadav, Roshan
    JOURNAL OF NEPAL MEDICAL ASSOCIATION, 2017, 56 (208) : 456 - 460
  • [6] Functional Outcome of Minimally Invasive Percutaneous Plate Osteosynthesis Using Locking Compression Plates in Distal Femur Fractures
    Kumar, S. Ravin
    Shetty, Sudeep
    Sreejesh, Saj
    Mohapatra, Amlan
    Deka, Rana Pratap
    INTERNATIONAL JOURNAL OF SCIENTIFIC STUDY, 2015, 2 (11) : 17 - 21
  • [7] Treatment of distal tibia end fractures by minimally invasive plate osteosynthesis
    Quang-Tri Le
    Ngoc-Thanh Do
    Minh-Hoang Nguyen
    Huu-Hung Phan
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2020, 11 : 33 - 36
  • [8] Minimally invasive percutaneous plate fixation of distal tibia fractures
    Bahari, Syah
    Lenehan, Brian
    Khan, Hamad
    McElwain, John P.
    ACTA ORTHOPAEDICA BELGICA, 2007, 73 (05): : 635 - 640
  • [9] Minimally invasive plate osteosynthesis (MIPO) in diaphyseal humerus and proximal humerus fractures
    Aksu, Neslihan
    Karaca, Sinan
    Kara, Ayhan Nedim
    Isiklar, Zekeriya Ugur
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2012, 46 (03) : 154 - 160
  • [10] Minimally invasive percutaneous plate osteosynthesis for closed distal tibial fractures: a consecutive study based on 25 patients
    Bhat R.
    Wani M.M.
    Rashid S.
    Akhter N.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (3) : 563 - 568