Particle Collection Efficiency of Polypropylene Nonwoven Filter Media Charged by Triode Corona Discharge

被引:6
作者
Fatihou, Ali [1 ]
Zouzou, Noureddine [1 ]
Dascalescu, Lucian [1 ]
机构
[1] Univ Poitiers, CNRS, UPR 3346, Pprime Inst,ISAE,ENSMA,Sci Phys Mecan Math & Info, F-86962 Futuroscope, France
关键词
Collection efficiency; corona charging; electric potential; electrostatic measurements; nonwoven filter media; submicron particles; triode configuration; AIR FILTER; TECHNOLOGY; FILTRATION; POLLUTION; EXHAUST;
D O I
10.1109/TIA.2017.2678979
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The aim of this paper is to evaluate the collection efficiency of submicron particles using electrically charged nonwoven filter media. A triode-type electrode arrangement consisting of a high-voltage wire-type ionizing electrode, a metallic grid, and grounded plate electrode is employed to control the distribution of electric charges deposited on the media. Surface electric potential measurement is carried out to study the evolution in time and the repartition in space of deposited charges. The collection efficiency is estimated by measuring the particle concentrations downstream and upstream of the charged filter media. The main results show good correlation between the surface potential level and the collection efficiency of submicron particles for several charging conditions. In particular, filtration performance increases with increasing the corona current through the media during the charging process. Increasing the electric field between the grid and the media during corona charging has also a positive effect on the collection efficiency. Results indicate that high collection performances could not be achieved using thin monolayer media.
引用
收藏
页码:3970 / 3976
页数:7
相关论文
共 34 条
[11]   Filtration characteristics of fibrous filter following an electrostatic precipitator [J].
Feng, Zhuangbo ;
Long, Zhengwei ;
Yu, Tao .
JOURNAL OF ELECTROSTATICS, 2016, 83 :52-62
[12]   Experimental and theoretical study of a novel electrostatic enhanced air filter (EEAF) for fine particles [J].
Feng, Zhuangbo ;
Long, Zhengwei ;
Mo, Jinhan .
JOURNAL OF AEROSOL SCIENCE, 2016, 102 :41-54
[13]   THE EFFECT OF PARTICLE CHARGE ON PENETRATION IN AN ELECTRET FILTER [J].
FJELD, RA ;
OWENS, TM .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1988, 24 (04) :725-731
[14]   Air pollution and cardiovascular disease [J].
Franchini, Massimo ;
Mannucci, Pier Mannuccio .
THROMBOSIS RESEARCH, 2012, 129 (03) :230-234
[15]  
Hinds WC., 1992, AEROSOL TECHNOLOGY P
[16]   Experimental investigation on the particle capture by a single fiber using microscopic image technique [J].
Key laboratory for Thermal Science and Power Engineering, Ministry of Education, Tsinghua University, Beijing, 100084, China .
Powder Technol., 2006, 3 (125-133)
[17]  
Hutten I.M., 2007, Handbook of nonwoven filter media, Vfirst
[18]   Modern electrostatic devices and methods for exhaust gas cleaning: A brief review [J].
Jaworek, Anatol ;
Krupa, Andrzej ;
Czech, Tadeusz .
JOURNAL OF ELECTROSTATICS, 2007, 65 (03) :133-155
[19]   Effect of particle loading on the collection performance of an electret cabin air filter for submicron aerosols [J].
Ji, JH ;
Bae, GN ;
Kang, SH ;
Hwang, J .
JOURNAL OF AEROSOL SCIENCE, 2003, 34 (11) :1493-1504
[20]   Electret properties of polypropylene fabrics [J].
Lowkis, B ;
Motyl, E .