Highly Sensitive Electrochemical Biosensor Using Folic Acid-Modified Reduced Graphene Oxide for the Detection of Cancer Biomarker

被引:35
作者
Geetha Bai, Renu [1 ,2 ]
Muthoosamy, Kasturi [1 ]
Tuvikene, Rando [2 ]
Nay Ming, Huang [3 ]
Manickam, Sivakumar [1 ,4 ]
机构
[1] Univ Nottingham Malaysia, Dept Chem & Environm Engn, Nanotechnol Res Grp, Fac Engn, Semenyih 43500, Malaysia
[2] Tallinn Univ, Sch Nat Sci & Hlth, EE-10120 Tallinn, Estonia
[3] Xiamen Univ Malaysia, Sch Energy & Chem Engn, New Energy Sci & Engn, Sepang 43900, Malaysia
[4] Univ Teknol Brunei, Petr & Chem Engn, Fac Engn, BE-1410 Bandar Seri Begawan, Brunei
关键词
folic acid; folate receptor; folate targeted; electrochemical sensor; cancer biomarker; rGO-FA; differential pulse voltammetry; biosensor; FOLATE RECEPTOR-ALPHA; TERMINAL PROTECTION; FUNCTIONALIZED GRAPHENE; GOLD NANOPARTICLES; THERMAL-STABILITY; QUANTUM DOTS; IN-VITRO; CELL; DELIVERY; DRUG;
D O I
10.3390/nano11051272
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The detection of cancer biomarkers in the early stages could prevent cancer-related deaths significantly. Nanomaterials combined with biomolecules are extensively used in drug delivery, imaging, and sensing applications by targeting the overexpressed cancer proteins such as folate receptors (FRs) to control the disease by providing earlier treatments. In this investigation, biocompatible reduced graphene oxide (rGO) nanosheets combined with folic acid (FA)-a vitamin with high bioaffinity to FRs-is utilized to develop an electrochemical sensor for cancer detection. To mimic the cancer cell environment, FR-beta protein is used to evaluate the response of the rGO-FA sensor. The formation of the rGO-FA nanocomposite was confirmed through various characterization techniques. A glassy carbon (GC) electrode was then modified with the obtained rGO-FA and analyzed via differential pulse voltammetry (DPV) for its specific detection towards FRs. Using the DPV technique, the rGO-FA-modified electrode exhibited a limit of detection (LOD) of 1.69 pM, determined in a linear concentration range from 6 to 100 pM. This excellent electrochemical performance towards FRs detection could provide a significant contribution towards future cancer diagnosis. Moreover, the rGO-FA sensing platform also showed excellent specificity and reliability when tested against similar interfering biomolecules. This rGO-FA sensor offers a great promise to the future medical industry through its highly sensitive detection towards FRs in a fast, reliable, and economical way.
引用
收藏
页数:15
相关论文
共 92 条
[1]   Folate receptor-targeted multimodal polymersomes for delivery of quantum dots and doxorubicin to breast adenocarcinoma: In vitro and in vivo evaluation [J].
Alibolandi, Mona ;
Abnous, Khalil ;
Sadeghi, Fatemeh ;
Hosseinkhani, Hossein ;
Ramezani, Mohammad ;
Hadizadeh, Farzin .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2016, 500 (1-2) :162-178
[2]   Egg albumin-folic acid nanocomplexes: Performance as a functional ingredient and biological activity [J].
Arzeni, Carolina ;
Perez, Oscar E. ;
Guy LeBlanc, Jean ;
Pilosof, Ana M. R. .
JOURNAL OF FUNCTIONAL FOODS, 2015, 18 :379-386
[3]   Graphene-based 3D scaffolds in tissue engineering: fabrication, applications, and future scope in liver tissue engineering [J].
Bai, Renu Geetha ;
Muthoosamy, Kasturi ;
Manickam, Sivakumar ;
Hilal-Alnaqbi, Ali .
INTERNATIONAL JOURNAL OF NANOMEDICINE, 2019, 14 :5753-5783
[4]   Graphene: A versatile platform for nanotheranostics and tissue engineering [J].
Bai, Renu Geetha ;
Ninan, Neethu ;
Muthoosamy, Kasturi ;
Manickam, Sivakumar .
PROGRESS IN MATERIALS SCIENCE, 2018, 91 :24-69
[5]   Acoustic cavitation induced generation of stabilizer-free, extremely stable reduced graphene oxide nanodispersion for efficient delivery of paclitaxel in cancer cells [J].
Bai, Renu Geetha ;
Muthoosamy, Kasturi ;
Shipton, Fiona Natalia ;
Manickam, Sivakumar .
ULTRASONICS SONOCHEMISTRY, 2017, 36 :129-138
[6]   Sonochemical and sustainable synthesis of graphene-gold (G-Au) nanocomposites for enzymeless and selective electrochemical detection of nitric oxide [J].
Bai, Renu Geetha ;
Muthoosamy, Kasturi ;
Zhou, Meifang ;
Ashokkumar, Muthupandian ;
Huang, Nay Ming ;
Manickam, Sivakumar .
BIOSENSORS & BIOELECTRONICS, 2017, 87 :622-629
[7]   The biogenic synthesis of a reduced graphene oxide-silver (RGO-Ag) nanocomposite and its dual applications as an antibacterial agent and cancer biomarker sensor [J].
Bai, Renu Geetha ;
Muthoosamy, Kasturi ;
Shipton, Fiona Natalia ;
Pandikumar, Alagarsamy ;
Rameshkumar, Perumal ;
Huang, Nay Ming ;
Manickam, Sivakumar .
RSC ADVANCES, 2016, 6 (43) :36576-36587
[8]   Functional Folate Receptor Alpha Is Elevated in the Blood of Ovarian Cancer Patients [J].
Basal, Eati ;
Eghbali-Fatourechi, Guiti Z. ;
Kalli, Kimberly R. ;
Hartmann, Lynn C. ;
Goodman, Karin M. ;
Goode, Ellen L. ;
Kamen, Barton A. ;
Low, Philip S. ;
Knutson, Keith L. .
PLOS ONE, 2009, 4 (07)
[9]  
Baset S, 2011, DIG J NANOMATER BIOS, V6, P709
[10]   Electro-oxidized Monolayer CVD Graphene Film Transducer for Ultrasensitive Impedimetric DNA Biosensor [J].
Benvidi, Ali ;
Saucedo, Nuvia M. ;
Ramnani, Pankaj ;
Villarreal, Claudia ;
Mulchandani, Ashok ;
Tezerjani, Marzieh Dehghan ;
Jahanbani, Shahriar .
ELECTROANALYSIS, 2018, 30 (08) :1783-1792