A combination of β-cyclodextrin functionalized magnetic graphene oxide nanoparticles with β-cyclodextrin-based sensor for highly sensitive and selective voltammetric determination of tetracycline and doxycycline in milk samples

被引:37
|
作者
Yakout, Amr A. [1 ,2 ]
Abd El-Hady, Deia [1 ,3 ]
机构
[1] Univ Jeddah, Fac Sci, Dept Chem, Jeddah, Saudi Arabia
[2] Univ Alexandria, Fac Sci, Dept Chem, Alexandria, Egypt
[3] Assiut Univ, Fac Sci, Dept Chem, Assiut 71516, Egypt
来源
RSC ADVANCES | 2016年 / 6卷 / 48期
关键词
CAPACITY ANODE MATERIAL; CHEMILUMINESCENCE DETERMINATION; AQUEOUS-SOLUTION; ADSORPTION; PERFORMANCE; RESIDUES; EXTRACTION; SORPTION; CARBON; WATER;
D O I
10.1039/c6ra03787a
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Food safety problems caused by tetracycline antibiotics residues are a significant concern due to their great risk to human health even at trace levels. In the current work, a highly sensitive and selective determination of similar chemical composition tetracycline (TC) and doxycycline (DC) antibiotics in milk samples was developed by offline solid phase extraction using beta-cyclodextrin functionalized magnetic graphene oxide nanoparticles (beta-CD-MGONPs) followed by differential pulse voltammetric determination with a beta-cyclodextrin modified carbon paste (beta-CD-MCP) sensor. beta-CD-MGONPs was prepared, characterized by XRD, FTIR, TEM, and TGA and applied for the removal of TC/DC using batch adsorption experiments. The effects of medium acidity, equilibration time, adsorbent dose, initial antibiotic concentration, and ionic strength were extensively investigated using UV-Vis spectrophotometry at optimal adsorption conditions. The experimental data are well described by the Langmuir isotherm and pseudo-second-order kinetic model. The maximum adsorption capacity was found to be 666.7 mg g(-1) for TC and 769.2 mg g(-1) for DC. Furthermore, loss in the removal efficiency was 3.5-5.6% after three adsorptiondesorption cycles. Then, the electrochemical response of the beta-CD-MCP sensor following beta-CDMGONPs extraction was investigated by differential pulse voltammetry (DPV) and cyclic voltammetry (CV). Under optimal electrochemical parameters, anodic differential pulse voltammetry (ADPV) at +320.0 mV and cathodic differential pulse voltammetry (CDPV) at -800.0 mV were selectively used to detect TC and DC, respectively. The response currents of the beta-CD-MCP sensor exhibited a linear relationship towards TC/DC concentrations ranging from 0.5-90.0 ng L-1. The limit of detection (LOD) of TC or DC was calculated as 0.18 ng L-1. Other validation parameters confirmed the adequate applicability of the proposed system to detect TC/DC in milk samples. The proposed platform showed advantages of simplicity, rapidity, reliability, and low cost compared to other previously published reports.
引用
收藏
页码:41675 / 41686
页数:12
相关论文
共 16 条
  • [1] Electrochemical Sensor for Ultrasensitive Determination of Bisphenol A based on Gold Nanoparticles/β-cyclodextrin Functionalized Reduced Graphene Oxide Nanocomposite
    Yun, Yang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (04): : 2778 - 2789
  • [2] An ultra-sensitive sensor based on β-cyclodextrin modified magnetic graphene oxide for detection of tryptophan
    Wang, Congli
    Li, Tingting
    Liu, Zhiguang
    Guo, Yujing
    Li, Chenzhong
    Dong, Chuan
    Shuang, Shaomin
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 781 : 363 - 370
  • [3] β-Cyclodextrin functionalized 3D reduced graphene oxide composite-based electrochemical sensor for the sensitive detection of dopamine
    Chen, Xuan
    Li, Na
    Rong, Yanqin
    Hou, Yuli
    Huang, Yu
    Liang, Wenting
    RSC ADVANCES, 2021, 11 (45) : 28052 - 28060
  • [4] Electrochemical biomimetic sensor based on oxime group-functionalized gold nanoparticles and nitrogen-doped graphene composites for highly selective and sensitive dimethoate determination
    Zhang, Ya
    Fa, Huan-bao
    He, Bin
    Hou, Chang-jun
    Huo, Dan-qun
    Xia, Tian-ci
    Yin, Wei
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2017, 21 (07) : 2117 - 2128
  • [5] A highly sensitive tetracycline sensor based on a combination of magnetic molecularly imprinted polymer nanoparticles and surface plasmon resonance detection
    Gao, Wanru
    Li, Pao
    Qin, Si
    Huang, Zhao
    Cao, Yanan
    Liu, Xia
    MICROCHIMICA ACTA, 2019, 186 (09)
  • [6] An Electrochemical Sensor for Simultaneous Stripping Determination of Cd(II) and Pb(II) Based on Gold Nanoparticles Functionalized β-cyclodextrin-graphene Hybrids
    Qin, Xiaoli
    Tang, Daili
    Zhang, Yunxiang
    Cheng, Yongbing
    He, Fang
    Su, Zhaohong
    Jiang, Hongmei
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (02): : 1517 - 1528
  • [7] A novel disposable sensor based on gold digital versatile disc chip modified with graphene oxide decorated with Ag nanoparticles/β-cyclodextrin for voltammetric measurement of naproxen
    Tarahomi, Somayeh
    Rounaghi, Gholam Hossein
    Daneshvar, Leili
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 286 : 445 - 450
  • [8] Highly Selective and Sensitive Voltammetric Sensor Based on Ruthenium Nanoparticle Anchored Calix[4]amidocrown-5 Functionalized Reduced Graphene Oxide: Simultaneous Determination of Quercetin, Morin and Rutin in Grape Wine
    Elcin, Serkan
    Yola, Mehmet Lutfi
    Eren, Tanju
    Girgin, Burcu
    Atar, Necip
    ELECTROANALYSIS, 2016, 28 (03) : 611 - 619
  • [9] A HIGHLY SENSITIVE AND SELECTIVE ENZYMATIC GLUCOSE SENSOR BASED ON PLATINUM NANOPARTICLES EMBEDDED WITH ACID TREATED REDUCED GRAPHENE OXIDE
    Hossain, M. F.
    Park, J. Y.
    2016 IEEE 29TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2016, : 278 - 281
  • [10] An ultrasensitive electrochemical sensor for quercetin based on 1-pyrenebutyrate functionalized reduced oxide graphene /mercapto-β-cyclodextrin /Au nanoparticles composite film
    Zhou, Zhidu
    Gu, Chunmeng
    Chen, Chao
    Zhao, Pengchen
    Xie, Yixi
    Fei, Junjie
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 288 : 88 - 95