Modeling a Large-Scale Battery Energy Storage System for Power Grid Application Analysis

被引:61
作者
Rancilio, Giuliano [1 ,2 ]
Lucas, Alexandre [1 ]
Kotsakis, Evangelos [1 ]
Fulli, Gianluca [1 ]
Merlo, Marco [2 ]
Delfanti, Maurizio [3 ]
Masera, Marcelo [1 ]
机构
[1] European Commiss, JRC, Via E Fermi 2749, I-21027 Ispra, VA, Italy
[2] Politecn Milan, Dept Energy, Piazza Leonardo Da Vinci 32, I-20133 Milan, Italy
[3] Ric Sistema Energet RSE SpA, Via R Rubattino, I-20134 Milan, Italy
关键词
BESS model; energy storage; Li-ion batteries; ancillary services; frequency regulation; LITHIUM-ION BATTERIES; EQUIVALENT-CIRCUIT MODELS; CHARGE ESTIMATION; SIMULATION; STATE; HYSTERESIS;
D O I
10.3390/en12173312
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The interest in modeling the operation of large-scale battery energy storage systems (BESS) for analyzing power grid applications is rising. This is due to the increasing storage capacity installed in power systems for providing ancillary services and supporting nonprogrammable renewable energy sources (RES). BESS numerical models suitable for grid-connected applications must offer a trade-off, keeping a high accuracy even with limited computational effort. Moreover, they are asked to be viable in modeling for real-life equipment, and not just accurate in the simulation of the electrochemical section. The aim of this study is to develop a numerical model for the analysis of the grid-connected BESS operation; the main goal of the proposal is to have a test protocol based on standard equipment and just based on charge/discharge tests, i.e., a procedure viable for a BESS owner without theoretical skills in electrochemistry or lab procedures, and not requiring the ability to disassemble the BESS in order to test each individual component. The BESS model developed is characterized by an experimental campaign. The test procedure itself is framed in the context of this study and adopted for the experimental campaign on a commercial large-scale BESS. Once the model is characterized by the experimental parameters, it undergoes the verification and validation process by testing its accuracy in simulating the provision of frequency regulation. A case study is presented for the sake of presenting a potential application of the model. The procedure developed and validated is replicable in any other facility, due to the low complexity of the proposed experimental set. This could help stakeholders to accurately simulate several layouts of network services.
引用
收藏
页数:26
相关论文
共 61 条
[1]  
[Anonymous], BATT EN STOR EU BARR
[2]  
[Anonymous], 2019, Directive (EU) 2019/944 of the European parliament and of the council of 5 june 2019 on common rules for the internal market for electricity and amending directive 2012/27/EU, V158, P125
[3]  
[Anonymous], 2017, Technical report
[4]  
[Anonymous], 2010, Battery Management Systems for Large Lithium-Ion Battery Packs
[5]   Estimation of state of charge for lithium-ion batteries - A Review [J].
Attanayaka, A. M. S. M. H. S. ;
Karunadasa, J. P. ;
Hemapala, K. T. M. U. .
AIMS ENERGY, 2019, 7 (02) :186-210
[6]   Li-NMC Batteries Model Evaluation with Experimental Data for Electric Vehicle Application [J].
Baczynska, Aleksandra ;
Niewiadomski, Waldemar ;
Goncalves, Ana ;
Almeida, Paulo ;
Luis, Ricardo .
BATTERIES-BASEL, 2018, 4 (01)
[7]   A study of the open circuit voltage characterization technique and hysteresis assessment of lithium-ion cells [J].
Barai, Anup ;
Widanage, W. Dhammika ;
Marco, James ;
McGordon, Andrew ;
Jennings, Paul .
JOURNAL OF POWER SOURCES, 2015, 295 :99-107
[8]  
Barcellona Simone, 2015, ScientificWorldJournal, V2015, P979321, DOI 10.1155/2015/979321
[9]   Application-independent protocol for predicting the efficiency of lithium-ion battery cells in operations [J].
Brivio, C. ;
Musolino, V. ;
Alet, P. -J. ;
Merlo, M. ;
Hutter, A. ;
Ballif, C. .
JOURNAL OF ENERGY STORAGE, 2018, 15 :415-422
[10]  
Brivio C., 2017, P 6 INT C CLEAN EL P