Dual source computed tomography based analysis of stent performance, its association with valvular calcification and residual aortic regurgitation after implantation of a balloon-expandable transcatheter heart valve

被引:2
作者
Gerstmeyer, Julius [1 ]
Kuetting, Maximilian [2 ]
Fujita, Buntaro [1 ]
Schuhbaeck, Annika [3 ]
Arnold, Martin [3 ]
Boergermann, Jochen [1 ]
Achenbach, Stephan [3 ]
Steinseifer, Ulrich [2 ]
Gummert, Jan [1 ]
Ensminger, Stephan [1 ]
机构
[1] Ruhr Univ Bochum, Dept Thorac & Cardiovasc Surg, Heart & Diabet Ctr NRW, Georgstr 11, D-32545 Bad Oeynhausen, Germany
[2] Rhein Westfal TH Aachen, Inst Appl Med Engn, Helmholtz Inst, Aachen, Germany
[3] Friedrich Alexander Univ Erlangen Nurnberg, Dept Cardiol, Erlangen, Germany
关键词
Transcatheter aortic valve implantation; Stent geometry; Calcification; Aortic regurgitation; Imaging; Computed tomography; LANDING ZONE CALCIFICATION; COREVALVE REVALVING SYSTEM; PARAVALVULAR REGURGITATION; ECCENTRICITY; PROSTHESIS; PREDICTORS; TAVI;
D O I
10.1093/icvts/ivw432
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: The aim of this study was to investigate the mutual influence of valvular calcifications and transcatheter aortic valve stent geometry during and after implantation of a balloon-expandable SAPIEN (R)/SAPIEN XT (R) protheses. Aortic valve calcification has been linked with adverse complications after transcatheter aortic valve implantation (TAVI). However, little is known about the fate of the calcifications after TAVI as well as its influence on transcatheter heart valve geometry. METHODS: Thirty one patients underwent cardiac dual source computed tomography (DSCT) before and after a TAVI with the Edwards SAPIEN/SAPIEN XT (R) prostheses. Detailed DSCT image analysis was performed with Mimics (R) and 3Matic (R) (both Materialise, Leuven, Belgium). RESULTS: Implanted stents reached an average degree of expansion of 84% and achieved good circularity despite the presence of fairly oval native annuli and a heterogeneous degree of valvular calcification. Both, the degree of stent expansion and the degree of stent eccentricity were inversely related to the degree of oversizing, but independent of the degree of valvular calcification and native annular ovality. Visualization of the position of calcific debris before and after TAVI showed that calcifications were shifted upwards and outwards as a consequence of the implantation procedure. The degree of stent eccentricity was related to residual aortic regurgitation grade >= 2. CONCLUSIONS: The SAPIEN (R)/SAPIEN XT (R) prostheses achieved good degrees of stent expansion and circularity regardless of the morphology of the landing zone. Increased stent ovality was associated with an elevated risk for aortic regurgitation. The total calcification volume, degree of annular ovality and stent expansion were not associated with residual AR.
引用
收藏
页码:506 / 513
页数:8
相关论文
共 19 条
  • [1] Bekeredjian R, 2015, J INVASIVE CARDIOL, V27, P172
  • [2] Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function
    Delgado, Victoria
    Ng, Arnold C. T.
    van de Veire, Nico R.
    van der Kley, Frank
    Schuijf, Joanne D.
    Tops, Laurens F.
    de Weger, Arend
    Tavilla, Giuseppe
    de Roos, Albert
    Kroft, Lucia J.
    Schalij, Martin J.
    Bax, Jeroen J.
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 (09) : 1114 - 1123
  • [3] Calcium distribution patterns of the aortic valve as a risk factor for the need of permanent pacemaker implantation after transcatheter aortic valve implantation
    Fujita, Buntaro
    Kuetting, Maximilian
    Seiffert, Moritz
    Scholtz, Smita
    Egron, Sandrine
    Prashovikj, Emir
    Boergermann, Jochen
    Schaefer, Timm
    Scholtz, Werner
    Preuss, Rainer
    Gummert, Jan
    Steinseifer, Ulrich
    Ensminger, Stephan M.
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (12) : 1385 - 1393
  • [4] Aortic valve calcium load before TAVI: Is it important?
    Haensig, Martin
    Rastan, Ardawan Julian
    [J]. ANNALS OF CARDIOTHORACIC SURGERY, 2012, 1 (02) : 160 - 164
  • [5] The German Aortic Valve Registry (GARY): in-hospital outcome
    Hamm, Christian W.
    Moellmann, Helge
    Holzhey, David
    Beckmann, Andreas
    Veit, Christof
    Figulla, Hans-Reiner
    Cremer, J.
    Kuck, Karl-Heinz
    Lange, Ruediger
    Zahn, Ralf
    Sack, Stefan
    Schuler, Gerhard
    Walther, Thomas
    Beyersdorf, Friedhelm
    Boehm, Michael
    Heusch, Gerd
    Funkat, Anne-Kathrin
    Meinertz, Thomas
    Neumann, Till
    Papoutsis, Konstantinos
    Schneider, Steffen
    Welz, Armin
    Mohr, Friedrich W.
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 (24) : 1588 - 1598
  • [6] Correlation of Device Landing Zone Calcification and Acute Procedural Success in Patients Undergoing Transcatheter Aortic Valve Implantations With the Self-Expanding CoreValve Prosthesis
    John, Daniel
    Buellesfeld, Lutz
    Yuecel, Seyrani
    Mueller, Ralf
    Latsios, Georg
    Beucher, Harald
    Gerckens, Ulrich
    Grube, Eberhard
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (02) : 233 - 243
  • [7] Koos R, 2011, J HEART VALVE DIS, V20, P83
  • [8] Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation
    Koos, Ralf
    Mahnken, Andreas Horst
    Dohmen, Guido
    Brehmer, Kathrin
    Guenther, Rolf W.
    Autschbach, Ruediger
    Marx, Nikolaus
    Hoffmann, Rainer
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 150 (02) : 142 - 145
  • [9] In vitro assessment of the influence of aortic annulus ovality on the hydrodynamic performance of self-expanding transcatheter heart valve prostheses
    Kuetting, Maximilian
    Sedaghat, Alexander
    Utzenrath, Marc
    Sinning, Jan-Malte
    Schmitz, Christoph
    Roggenkamp, Jan
    Werner, Nikos
    Schmitz-Rode, Thomas
    Steinseifer, Ulrich
    [J]. JOURNAL OF BIOMECHANICS, 2014, 47 (05) : 957 - 965
  • [10] "Device Landing Zone" Calcification, Assessed by MSCT, as a Predictive Factor for Pacemaker Implantation After TAVI
    Latsios, George
    Gerckens, Ulrich
    Buellesfeld, Lutz
    Mueller, Ralf
    John, Daniel
    Yuecel, Seyrani
    Syring, Joerg
    Sauren, Barthel
    Grube, Eberhard
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (03) : 431 - 439