Reliability and difference in neck extensor muscles strength measured by a portable dynamometer in individuais with and without chronic neck pain

被引:1
作者
Grondin, Francis [1 ,2 ]
Colman, David [3 ,4 ]
Peyrot, Nicolas [1 ,5 ]
Maillard, Olivier [6 ]
Freppel, Sebastien [7 ]
Caderby, Teddy [1 ]
Perdrix, Yannick [2 ]
机构
[1] Univ La Reunion, Lab IRISSE, UFR Sci Homme & Environm, St Denis, Reunion, France
[2] Ctr Hosp Univ La Reunion, IFMK la Reunion, Sch Physiotherapy, St Denis, Reunion, France
[3] Liege Univ Hosp Ctr, Dept Phys Med & Rehabil, Liege, Belgium
[4] Univ Liege, Dept Sport & Rehabil Sci, Liege, Belgium
[5] Le Mans Univ, MIP, Mouvement Interact Performance, EA 43 34, F-72000 Le Mans, France
[6] Ctr Hosp Univ La Reunion, Ctr Clin Invest CIC 1410, INSERM, St Pierre, Reunion, France
[7] Ctr Hosp Univ La Reunion, Neurosurg Dept, St Pierre, Reunion, France
关键词
Cervical spine; neck muscle; reliability; dynamometer strength; CERVICAL RANGE; ENDURANCE; VALIDITY; MOTION; WOMEN; FEAR;
D O I
10.1080/10669817.2021.2024676
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: There are limited reports about the reliability of measuring neck extensor muscle strength using a portable dynamometer in neck pain patients. The aims of the current study were 1) to investigate intra- and inter-rater reliability of neck extensor isometric strength measurement using a portable dynamometer in patients with chronic nonspecific neck pain (CNSNP) and 2) to compare neck extensor isometric strength in participants with and without CNSNP. Methods: Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were followed. Two examiners received a 15-minute training before enrollment. Inter-rater reliability was assessed with a 10-minute interval between measurements, and intra-rater reliability was assessed with a 10-day interval. Three trials were assessed and examiners were blind to the strength values (in Newtons) from other sessions of 20 individuals with CNSNP (mean +/- SD= 37.9 +/- 9.8y; Neck Disability Index 29.2 +/- 7.4%) and 20 individuals with other musculoskeletal disorders (mean +/- SD = 32.8 +/- 46.2y). Results: lntra-rater reliability was excellent with intraclass correlation coefficient (ICC)(3,1) of 0.95 (0:0.90-0.97) and inter-rater reliability was good to excellent with ICC(2,1) of 0.88 (CI:0.770.94) in CNSNP. No significant difference of neck extensor strength was found between CNSNP (93.27N +/- 31.94) and Individuals without CNSNP (111.43N +/- 40.11) (p > 0.05). Conclusion: A portable dynamometer is a reliable tool for measuring maximal isometric neck extension strength in individuals with CNSNP. Slightly but no significant differences of neck extensor strength values between individuals with and without CNSNP. Future studies are needed to assess the generalizability of the findings in patients with other muscle deconditioning.
引用
收藏
页码:192 / 198
页数:7
相关论文
共 30 条
[21]   Maximal Voluntary Isometric Neck Strength Deficits in Adults With Whiplash-Associated Disorders and Association With Pain and Fear of Movement [J].
Pearson, Isabelle ;
Reichert, Alison ;
De Serres, Sophie J. ;
Dumas, Jean-Pierre ;
Cote, Julie N. .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2009, 39 (03) :179-187
[22]   Validity and reliability of a low-cost dynamometer to assess maximal isometric strength of upper limb Low cost dynamometry and isometric strength of upper limb [J].
Romero-Franco, Natalia ;
Fernandez-Dominguez, Juan C. ;
Montano-Munuera, Juan A. ;
Romero-Franco, Javier ;
Jimenez-Reyes, Pedro .
JOURNAL OF SPORTS SCIENCES, 2019, 37 (15) :1787-1793
[23]  
Salmon DM., 2018, J STRENGTH COND RES, V32, P42
[24]   Reliability of Isometric Strength Measurements in Trunk and Neck Region: Patients With Chronic Neck Pain Compared With Pain-Free Persons [J].
Scheuer, Raphael ;
Friedrich, Martin .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2010, 91 (12) :1878-1883
[25]   Rest and treatment/rehabilitation following sport-related concussion: a systematic review [J].
Schneider, Kathryn J. ;
Leddy, John J. ;
Guskiewicz, Kevin M. ;
Seifert, Tad ;
McCrea, Michael ;
Silverberg, Noah D. ;
Feddermann-Demont, Nina ;
Iverson, Grant L. ;
Hayden, Alix ;
Makdissi, Michael .
BRITISH JOURNAL OF SPORTS MEDICINE, 2017, 51 (12) :930-934
[26]   Reliability and Validity of Clinical Tests for Measuring Strength or Endurance of Cervical Muscles: A Systematic Review and Meta-analysis [J].
Selistre, Luiz Fernando Approbato ;
Melo, Cristiane de Sousa ;
de Noronha, Marcos Amaral .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2021, 102 (06) :1210-1227
[27]   Reliability and group differences in quantitative cervicothoracic measures among individuals with and without chronic neck pain [J].
Shahidi, Bahar ;
Johnson, Cynthia L. ;
Curran-Everett, Douglas ;
Maluf, Katrina S. .
BMC MUSCULOSKELETAL DISORDERS, 2012, 13
[28]   Reliability and validity of measurements of cervical retraction strength obtained with a hand-held dynamometer [J].
Tudini, Frank ;
Myers, Bradley ;
Bohannon, Richard .
JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2019, 27 (04) :222-228
[29]   Test-retest reliability of a handheld dynamometer for measurement of isometric cervical muscle strength [J].
Vannebo, Katrine Tranaas ;
Iversen, Vegard Moe ;
Fimland, Marius Steiro ;
Mork, Paul Jarle .
JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2018, 31 (03) :557-565
[30]   Decreased isometric neck strength in women with chronic neck pain and the repeatability of neck strength measurements [J].
Ylinen, J ;
Salo, P ;
Nykänen, M ;
Kautiainen, H ;
Häkkinen, A .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2004, 85 (08) :1303-1308