Reliability and difference in neck extensor muscles strength measured by a portable dynamometer in individuais with and without chronic neck pain

被引:1
作者
Grondin, Francis [1 ,2 ]
Colman, David [3 ,4 ]
Peyrot, Nicolas [1 ,5 ]
Maillard, Olivier [6 ]
Freppel, Sebastien [7 ]
Caderby, Teddy [1 ]
Perdrix, Yannick [2 ]
机构
[1] Univ La Reunion, Lab IRISSE, UFR Sci Homme & Environm, St Denis, Reunion, France
[2] Ctr Hosp Univ La Reunion, IFMK la Reunion, Sch Physiotherapy, St Denis, Reunion, France
[3] Liege Univ Hosp Ctr, Dept Phys Med & Rehabil, Liege, Belgium
[4] Univ Liege, Dept Sport & Rehabil Sci, Liege, Belgium
[5] Le Mans Univ, MIP, Mouvement Interact Performance, EA 43 34, F-72000 Le Mans, France
[6] Ctr Hosp Univ La Reunion, Ctr Clin Invest CIC 1410, INSERM, St Pierre, Reunion, France
[7] Ctr Hosp Univ La Reunion, Neurosurg Dept, St Pierre, Reunion, France
关键词
Cervical spine; neck muscle; reliability; dynamometer strength; CERVICAL RANGE; ENDURANCE; VALIDITY; MOTION; WOMEN; FEAR;
D O I
10.1080/10669817.2021.2024676
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: There are limited reports about the reliability of measuring neck extensor muscle strength using a portable dynamometer in neck pain patients. The aims of the current study were 1) to investigate intra- and inter-rater reliability of neck extensor isometric strength measurement using a portable dynamometer in patients with chronic nonspecific neck pain (CNSNP) and 2) to compare neck extensor isometric strength in participants with and without CNSNP. Methods: Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were followed. Two examiners received a 15-minute training before enrollment. Inter-rater reliability was assessed with a 10-minute interval between measurements, and intra-rater reliability was assessed with a 10-day interval. Three trials were assessed and examiners were blind to the strength values (in Newtons) from other sessions of 20 individuals with CNSNP (mean +/- SD= 37.9 +/- 9.8y; Neck Disability Index 29.2 +/- 7.4%) and 20 individuals with other musculoskeletal disorders (mean +/- SD = 32.8 +/- 46.2y). Results: lntra-rater reliability was excellent with intraclass correlation coefficient (ICC)(3,1) of 0.95 (0:0.90-0.97) and inter-rater reliability was good to excellent with ICC(2,1) of 0.88 (CI:0.770.94) in CNSNP. No significant difference of neck extensor strength was found between CNSNP (93.27N +/- 31.94) and Individuals without CNSNP (111.43N +/- 40.11) (p > 0.05). Conclusion: A portable dynamometer is a reliable tool for measuring maximal isometric neck extension strength in individuals with CNSNP. Slightly but no significant differences of neck extensor strength values between individuals with and without CNSNP. Future studies are needed to assess the generalizability of the findings in patients with other muscle deconditioning.
引用
收藏
页码:192 / 198
页数:7
相关论文
共 30 条
[1]  
Burton A, 2000, PHYSIOTHERAPY, V86, P94, DOI [10.1016/S0031-9406, DOI 10.1016/S0031-9406(05)61211-4, 10.1016/S0031-9406(05)61211-4]
[2]   Differences in isometric neck muscle strength between healthy controls and women with chronic neck pain: The use of a reliable measurement [J].
Cagnie, Barbara ;
Cools, Ann ;
De Loose, Veerle ;
Cambier, Dirk ;
Danneels, Lieven .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2007, 88 (11) :1441-1445
[3]   Evaluation of cervical range of motion and isometric neck muscle strength: reliability and validity [J].
Chiu, TTW ;
Lo, SK .
CLINICAL REHABILITATION, 2002, 16 (08) :851-858
[4]   Estimation of grip force using the Grip-ball dynamometer [J].
Chkeir, Aly ;
Jaber, Rana ;
Hewson, David J. ;
Duchene, Jacques .
MEDICAL ENGINEERING & PHYSICS, 2013, 35 (11) :1698-1702
[5]   Clinimetric evaluation of methods to measure muscle functioning in patients with non-specific neck pain: a systematic review [J].
de Koning, Chantal H. P. ;
van den Heuvel, Sylvia P. ;
Staal, J. Bart ;
Smits-Engelsman, Bouwien C. M. ;
Hendriks, Erik J. M. .
BMC MUSCULOSKELETAL DISORDERS, 2008, 9 (1)
[6]   Intrarater and Inter-rater Reliability of Maximal Voluntary Neck Muscle Strength Assessment Using a Handheld Dynamometer in Women With Headache and Healthy Women [J].
de Oliveira Camevalli, Ana Paula ;
Bevilaqua-Grossi, Debora ;
Sobral Oliveira, Ana Izabela ;
Carvalho, Gabriela Ferreira ;
Femandez-De-Las-Penas, Cesar ;
Lima Florencio, Lidiane .
JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2018, 41 (07) :621-627
[7]   Does muscle morphology change in chronic neck pain patients? - A systematic review [J].
De Pauw, R. ;
Coppieters, I. ;
Kregel, J. ;
De Meulemeester, K. ;
Danneels, L. ;
Cagnie, B. .
MANUAL THERAPY, 2016, 22 :42-49
[8]   INTRARATER RELIABILITY OF NECK STRENGTH MEASUREMENT OF RUGBY UNION PLAYERS USING A HANDHELD DYNAMOMETER [J].
Geary, Kevin ;
Green, Brian S. ;
Delahunt, Eamonn .
JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2013, 36 (07) :444-449
[9]   Examination of Regional Interdependence Theory in Chronic Neck Pain: Interpretations from Correlation of Strength Measures in Cervical and Pain-Free Regions [J].
Ghamkhar, Leila ;
Arab, Amir Massoud ;
Nourbakhsh, Mohammad Reza ;
Kahlaee, Amir Hossein ;
Zolfaghari, Reyhaneh .
PAIN MEDICINE, 2020, 21 (02) :E182-E190
[10]   MAXIMUM NECK EXTENSION STRENGTH AND RELATIVE NECK MUSCULAR LOAD IN DIFFERENT CERVICAL-SPINE POSITIONS [J].
HARMSRINGDAHL, K ;
SCHULDT, K .
CLINICAL BIOMECHANICS, 1989, 4 (01) :17-24