Fast detection of low concentration carbon monoxide using calcium-loaded tin oxide sensors

被引:61
作者
Ghosh, Saptarshi [1 ]
Narjinary, Mousumi [1 ]
Sen, Amarnath [1 ]
Bandyopadhyay, Rajib [2 ]
Roy, Somenath [1 ]
机构
[1] CSIR Cent Glass & Ceram Res Inst, Sensor & Actuator Div, Kolkata 700032, India
[2] Jadavpur Univ, Instrumentat & Elect Engn Dept, Kolkata 700098, India
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2014年 / 203卷
关键词
Tin oxide; Calcium loading; Sonochemical synthesis; Carbon monoxide sensors; SNO2 GAS SENSORS; THIN-FILMS; DIOXIDE; CO; MAGNESIUM; HUMIDITY; NANOWIRE; HYDROGEN; ARRAY;
D O I
10.1016/j.snb.2014.06.111
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solid state sensors with noble metal-loaded tin oxide as sensing elements are widely used for the detection of flammable and toxic gases and volatile organic compounds (VOCs). Apart from rendering high cost, incorporation of noble metals often increases the preconditioning time and introduces a drift in baseline properties of the sensors. Herein, we report on the development of stable and economically viable sensor modules for fast and efficient detection of carbon monoxide (CO) in air. The sensing layer comprises sonochemically synthesized calcium-loaded tin oxide (Ca-SnO2) nanocrystals, in which calcium primarily gets segregated at the SnO2 grain boundaries as calcium oxide (CaO) and thereby restricts the growth of SnO2 particles. Due to larger ionic radius of Ca2+ as compared to that of Sn4+, a minute quantity of calcium can be doped as well into the SnO2 lattice. The variation of calcium concentration in SnO2 has a prominent effect on the sensor performance, where 5 wt% calcium loading shows the highest sensor response. The sensors exhibit a lower detection limit of 1 ppm CO in air. The response time (10-12 s) and recovery time (30-45 s) of our sensors, for different concentrations of CO, are equivalent or less compared to those of commercially available metal-oxide sensors. Additionally, a highly stable baseline with minimal drift even after being operational for over 1.5 years is observed. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:490 / 496
页数:7
相关论文
共 32 条
[1]  
[Anonymous], 2000, AIR QUAL GUID EUR, P32
[2]  
Babar A. R., 2011, J SEMICOND, V32
[3]   The reaction of oxygen with CO complexes on calcium oxide and magnesium oxide [J].
Bailes, M ;
Stone, FS .
TOPICS IN CATALYSIS, 2000, 11 (1-4) :213-222
[4]   Structure and electrochemical properties of novel mixed Li(Fe1-xMx)SO4F (M = Co, Ni, Mn) phases fabricated by low temperature ionothermal synthesis [J].
Barpanda, Prabeer ;
Recham, Nadir ;
Chotard, Jean-Noel ;
Djellab, Karim ;
Walker, Wesley ;
Armand, Michel ;
Tarascon, Jean-Marie .
JOURNAL OF MATERIALS CHEMISTRY, 2010, 20 (09) :1659-1668
[5]   The effect of palladium incorporation on methane sensitivity of antimony doped tin dioxide [J].
Chatterjee, K ;
Chatterjee, S ;
Banerjee, A ;
Raut, M ;
Pal, NC ;
Sen, A ;
Maiti, HS .
MATERIALS CHEMISTRY AND PHYSICS, 2003, 81 (01) :33-38
[6]   Sonochemically prepared tin-dioxide based composition for methane sensor [J].
Das, N ;
Halder, AK ;
Sen, JMA ;
Maiti, HS .
MATERIALS LETTERS, 2006, 60 (08) :991-994
[7]   Vanadium doped tin dioxide as a novel sulfur dioxide sensor [J].
Das, S. ;
Chakraborty, S. ;
Parkash, O. ;
Kumar, D. ;
Bandyopadhyay, S. ;
Samudrala, S. K. ;
Sen, A. ;
Maiti, H. S. .
TALANTA, 2008, 75 (02) :385-389
[8]  
Hassouna M.E. M, 2012, Int. J. Nanomat. and Biostruct., V2, P44
[9]  
He JH, 2006, SMALL, V2, P116, DOI 10.1002/smll.200500210
[10]   Low temperature Pd/SnO2 sensor for carbon monoxide detection [J].
Kim, Beomseok ;
Lu, Yijiang ;
Hannon, Ami ;
Meyyappan, M. ;
Li, Jing .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 177 :770-775