Resorbable plate osteosynthesis of sagittal split osteotomies with major bone movement

被引:35
作者
Landes, CA [1 ]
Kriener, S [1 ]
机构
[1] Univ Frankfurt, Klin Kiefer & Plast Gesichtschirurg, Med Ctr, Senckenberg Inst Pathol, D-60596 Frankfurt, Germany
关键词
D O I
10.1097/01.PRS.0000056867.28731.0E
中图分类号
R61 [外科手术学];
学科分类号
摘要
This study evaluates resorbable miniplate osteosyntheses in sagittal split osteotomies with major bone repositioning. Two resorbable 2.0-mm miniplate systems, MacroSorb (Macropore, San Diego, Calif) and PolyMax (Synthes, Oberdorf, Switzerland), were compared consecutively. Amorphous 70:30 poly-L/DL-lactide copolymer plates sustain continuous hydrolysis through water penetration into the implant body during the first 6 months in situ. This breaks copolymer chains into smaller particles, which later become degraded through phagocytotic cells. Eighteen patients, 10 women and eight men, 16 to 57 years old (average, 27 years) were examined. They had severe dysgnathia caused by congenital craniofacial malformations, systemic disorders, trauma, amelogenesis imperfecta, oligodontia, and other conditions, and they needed five 8- to 10-mm and 13 major 10- to 12-mm repositions. Twelve sagittal split osteotomies were fixed with 12 MacroSorb plates in six patients, and 24 osteotomies were filled with 32 PolyMax plates in 12 patients. Ten mandibular plate, screw, hard-tissue, and soft-tissue specimens were taken at 3, 6, 9, or 12 months postoperatively in secondary operations (e.g., dental implant placement). Follow-up ranged from 4 to 19 months; all osteosyntheses reossified. Four patients showed proximal fragments rotated up to 5 mm sagittally anteriorly and nonaligned burr holes on the postoperative radiogram, suggesting plate fractures or screw pullout. When plate fracture was noted, guided occlusion was maintained 4 weeks after surgery. Occlusal, radiologic, and skeletal results remained stable. After starting fixation with two plates on each side, no more plate fractures were seen. In three other patients, minor skeletal relapses up to 3 mm horizontally resulted. Local histologic inspection of specimens showed thorough osseous union. Screw remnants embedded in bone made screw pullout unlikely; rather, screw-head or plate fractures were found as multiple degraded particles. Microscopy showed a chronic foreign body reaction. Two patients (11 percent) developed a sterile fistula 3 and 4 months after surgery, draining implant debris. Here, the biopsies showed a granulocytic infiltrate that subsided clinically after excisional biopsy. The assignment of MacroSorb plates followed by PolyMax plates was done in an otherwise unchanged treatment protocol. Comparison of the number of patients in each group with stable osteosyntheses and regular healing showed no significant differences by Fisher's exact test (p = 0.1516); therefore, the authors focused on the combined results for both treatments. The current osteosynthesis systems showed sufficient stability for mandibular fixation after sagittal split osteotomy and repositioning more than 10 mm distant when two plates were applied to each side; however, 27 percent of patients had complications, including relapses. Disadvantages were the cost, breakability, diameter, and need to place the screws vertically to the plate, necessitating a bent instrument or transbuccal incisions.
引用
收藏
页码:1828 / 1840
页数:13
相关论文
共 48 条
[1]   FOREIGN-BODY REACTIONS TO RESORBABLE POLY(L-LACTIDE) BONE PLATES AND SCREWS USED FOR THE FIXATION OF UNSTABLE ZYGOMATIC FRACTURES [J].
BERGSMA, EJ ;
ROZEMA, FR ;
BOS, RRM ;
DEBRUIJN, WC .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (06) :666-670
[2]   Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation:: a review [J].
Böstman, O ;
Pihlajamäki, H .
BIOMATERIALS, 2000, 21 (24) :2615-2621
[3]  
Bostman OM, 1996, CLIN ORTHOP RELAT R, P233
[4]  
Böstman OM, 2000, CLIN ORTHOP RELAT R, P216
[5]   THE FATE OF MINIPLATES IN FACIAL TRAUMA AND ORTHOGNATHIC SURGERY - A RETROSPECTIVE STUDY [J].
BROWN, JS ;
TROTTER, M ;
CLIFFE, J ;
WARDBOOTH, RP ;
WILLIAMS, ED .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1989, 27 (04) :306-315
[6]   FIXATION WITH BIOABSORBABLE SCREWS FOR THE TREATMENT OF FRACTURES OF THE ANKLE [J].
BUCHOLZ, RW ;
HENRY, S ;
HENLEY, MB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (03) :319-324
[7]  
Champy M, 1992, Chirurgie, V118, P596
[8]   New bioresorbable pin for the reduction of small bony fragments: Design, mechanical properties and in vitro degradation [J].
Claes, LE ;
Ignatius, AA ;
Rehm, KE ;
Scholz, C .
BIOMATERIALS, 1996, 17 (16) :1621-1626
[9]  
Dumbach J, 1984, Dtsch Z Mund Kiefer Gesichtschir, V8, P145
[10]   The fate of resorbable poly-L-lactic/polyglycolic acid (LactoSorb) bone fixation devices in orthognathic surgery [J].
Edwards, RC ;
Kiely, KD ;
Eppley, BL .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 59 (01) :19-25