Discriminant Value of Custom Ocular Response Analyzer Waveform Derivatives in Forme Fruste Keratoconus

被引:31
作者
Luz, Allan [1 ,4 ,5 ]
Lopes, Bernardo [1 ,5 ,6 ]
Hallahan, Katie M. [2 ,3 ]
Valbon, Bruno [5 ,6 ]
Fontes, Bruno [6 ]
Schor, Paulo [1 ]
Dupps, William J., Jr. [2 ,3 ]
Ambrosio, Renato, Jr. [1 ,5 ,6 ]
机构
[1] Univ Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
[2] Cleveland Clin, Cole Eye Inst, Cleveland, OH 44106 USA
[3] Cleveland Clin, Biomed Engn, Lerner Res Inst, Cleveland, OH 44106 USA
[4] Hosp Olhos de Sergipe, Aracaju, Brazil
[5] Rio de Janeiro Corneal Tomog & Biomech Study Grp, Rio De Janeiro, Brazil
[6] Inst Olhos Renato Ambrosio & Visare Personal Lase, Rio De Janeiro, Brazil
关键词
CORNEAL BIOMECHANICAL PROPERTIES; IN-SITU-KERATOMILEUSIS; UNILATERAL KERATOCONUS; NORMAL EYES; ECTASIA; ABERRATIONS; PARAMETERS; SCORE;
D O I
10.1016/j.ajo.2015.12.020
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the performance of corneal hysteresis (CH), corneal resistance factor (CRF), 37 Ocular Response Analyzer (ORA) waveform parameters, and 15 investigator-derived ORA variables in differentiating forme fruste keratoconus (KC) from normal corneas. DESIGN: Case-control study. METHODS: Seventy-eight eyes of 78 unaffected patients and 21 topographically normal eyes of 21 forme fruste KC patients with topographically manifest KC in the contralateral eye were matched for age, the thinnest point of the cornea, central corneal thickness, and maximum keratometry. Fifteen candidate variables were derived from exported ORA signals to characterize putative indicators of biomechanical behavior, and 37 waveform parameters were tested. Differences between groups were assessed by the Mann-Whitney test. The area under the receiver operating characteristic curve (AUROC) was used to compare the diagnostic performance. RESULTS: Ten of 54 parameters reached significant differences between the groups (Mann-Whitney test, P <.05). Neither CRF nor CH differed significantly between the groups. Among the ORA waveform measurements, the best parameters were those related to the area under the first peak, plarea, and p1area1 (AUROC, 0.714 +/- 0.064 and 0.721 +/- 0.065, respectively). Among the investigator ORA variables, a measure incorporating the pressure-deformation relationship of the entire response cycle performed best (hysteresis loop area, AUROC, 0.694 +/- 0.067). CONCLUSION: Waveform-derived ORA parameters, including a custom measure incorporating the pressure deformation relationship of the entire response cycle, performed better than traditional CH and CRF parameters in differentiating forme fruste KC from normal corneas. (C) 2016 by Elsevier Inc. All rights reserved.
引用
收藏
页码:14 / 21
页数:8
相关论文
共 29 条
[1]   Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconus [J].
Ambrosio, Renato, Jr. ;
Alonso, Ruiz Simonato ;
Luz, Allan ;
Coca Velarde, Luis Guillermo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) :1851-1859
[2]   Risk factors for ectasia after LASIK [J].
Binder, Perry S. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (12) :2010-2011
[3]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[4]   Corneal Biomechanical Metrics in Eyes With Refraction of-19-00 to+9.00 D in Healthy Brazilian Patients [J].
Fontes, Bruno M. ;
Ambrosio, Renato ;
Alonso, Ruiz S. ;
Jardim, Daniela ;
Velarde, Guillermo C. ;
Nose, Walton .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (09) :941-945
[5]   Ocular Response Analyzer Measurements in Keratoconus With Normal Central Corneal Thickness Compared With Matched Normal Control Eyes [J].
Fontes, Bruno M. ;
Ambrosio, Renato, Jr. ;
Velarde, Guillermo Coca ;
Nose, Walton .
JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (03) :209-215
[6]   Corneal Biomechanical Metrics and Anterior Segment Parameters in Mild Keratoconus [J].
Fontes, Bruno M. ;
Ambrosio, Renato, Jr. ;
Jardim, Daniela ;
Velarde, Guillermo C. ;
Nose, Walton .
OPHTHALMOLOGY, 2010, 117 (04) :673-679
[7]   Method for optical coherence elastography of the cornea [J].
Ford, Matthew R. ;
Dupps, William J., Jr. ;
Rollins, Andrew M. ;
Roy, Abhijit Sinha ;
Hu, Zhilin .
JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (01)
[8]   Discriminant Value of Custom Ocular Response Analyzer Waveform Derivatives in Keratoconus [J].
Hallahan, Katie M. ;
Roy, Abhijit Sinha ;
Ambrosio, Renato, Jr. ;
Salomao, Marcella ;
Dupps, William J., Jr. .
OPHTHALMOLOGY, 2014, 121 (02) :459-468
[9]   Unilateral keratoconus - Incidence and quantitative topographic analysis [J].
Holland, DR ;
Maeda, N ;
Hannush, SB ;
Riveroll, LH ;
Green, MT ;
Klyce, SD ;
Wilson, SE .
OPHTHALMOLOGY, 1997, 104 (09) :1409-1413
[10]   Corneal Biomechanics as a Function of Intraocular Pressure and Pachymetry by Dynamic Infrared Signal and Scheimpflug Imaging Analysis in Normal Eyes [J].
Huseynova, Tukezban ;
Waring, George O. ;
Roberts, Cynthia ;
Krueger, Ronald R. ;
Tomita, Minoru .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (04) :885-893