Design, simulation and testing of large area silicon drift detectors and detector array for X-ray spectroscopy

被引:0
|
作者
Zhang, WC [1 ]
Li, Z [1 ]
Siddons, DP [1 ]
Huang, W [1 ]
Zhao, LJ [1 ]
Li, CJ [1 ]
Kakuno, EM [1 ]
Pietraski, P [1 ]
机构
[1] Brookhaven Natl Lab, Upton, NY 11973 USA
来源
1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3 | 1999年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Large area (25 mm(2)) silicon drift detectors and detector arrays (5x5) have been designed, simulated, and fabricated for M-ray spectroscopy. On the anode side, the hexagonal drift detector was designed with self-biasing spiral cathode rings (p(+)) of fixed resistance between rings and with a grounded guard anode to separate surface current fi om the anode current. Two designs have been used for the P-side: symmetric self-biasing spiral cathode rings (p(+)) and a uniform backside p(+) implant. Only 3 to 5 electrodes are needed to bias the detector plus an anode for signal collection. With graded electrical potential, a sub-nanoampere anode current, and a very small anode capacitance, an initial FWHM of 1.3 keV, without optimization of all parameters, has been obtained for 5.9 keV Fe-55 X-ray at RT using a uniform backside detector.
引用
收藏
页码:322 / 326
页数:3
相关论文
共 50 条
  • [1] Design, simulation and testing of large area silicon drift detectors and detector array for X-ray spectroscopy
    Zhang, WC
    Li, Z
    Siddons, DP
    Huang, T
    Zhao, LJ
    Kakuno, EM
    Pietraski, P
    Li, CJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) : 1381 - 1385
  • [2] Large-area linear Silicon Drift Detector design for X-ray experiments
    Rachevski, A.
    Zampa, G.
    Zampa, N.
    Campana, R.
    Evangelista, Y.
    Giacomini, G.
    Picciotto, A.
    Bellutti, P.
    Feroci, M.
    Labanti, C.
    Piemonte, C.
    Vacchi, A.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [3] Large area silicon drift detectors system for high precision timed x-ray spectroscopy
    Miliucci, M.
    Iliescu, M.
    Sgaramella, F.
    Bazzi, M.
    Bosnar, D.
    Bragadireanu, M.
    Carminati, M.
    Cargnelli, M.
    Clozza, A.
    Curceanu, C.
    Deda, G.
    De Paolis, L.
    Del Grande, R.
    Fiorini, C.
    Guaraldo, C.
    Iwasaki, M.
    King, P.
    Sandri, P. Levi
    Marton, J.
    Moskal, P.
    Napolitano, F.
    Niedzwiecki, S.
    Piscicchia, K.
    Scordo, A.
    Shi, H.
    Silarski, M.
    Sirghi, D.
    Sirghi, F.
    Skurzok, M.
    Spallone, A.
    Tuechler, M.
    Doce, O. Vazquez
    Zmeskal, J.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2022, 33 (09)
  • [4] Multichannel silicon drift detectors for X-ray spectroscopy
    Lechner, P
    Buttler, W
    Fiorini, C
    Hartmann, R
    Kemmer, J
    Krause, N
    Leutenegger, P
    Longoni, A
    Soltau, H
    Stötter, D
    Stötter, R
    Strüder, L
    Weber, U
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS III, 2000, 4012 : 592 - 599
  • [5] The X-Ray Spectroscopic Performance of a Very Large Area Silicon Drift Detector
    Zampa, Gianluigi
    Rashevsky, Alexander
    Vacchi, Andrea
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 832 - 835
  • [6] Imaging performance of a large-area Silicon Drift Detector for X-ray astronomy
    Campana, R.
    Zampa, G.
    Feroci, M.
    Vacchi, A.
    Bonvicini, V.
    Del Monte, E.
    Evangelista, Y.
    Fuschino, F.
    Labanti, C.
    Marisaldi, M.
    Muleri, F.
    Pacciani, L.
    Rapisarda, M.
    Rashevsky, A.
    Rubini, A.
    Soffitta, P.
    Zampa, N.
    Baldazzi, G.
    Costa, E.
    Donnarumma, I.
    Grassi, M.
    Lazzarotto, F.
    Malcovati, P.
    Mastropietro, M.
    Morelli, E.
    Picolli, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 (01): : 22 - 30
  • [7] A monolithic array of 77 Silicon Drift Detectors for X-ray spectroscopy and gamma-ray imaging applications
    Fiorini, C
    Bellini, M
    Gola, A
    Longoni, A
    Perotti, E
    Lechner, P
    Soltau, H
    Strüder, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 1165 - 1170
  • [8] A monolithic array of 77 silicon drift detectors for X-ray spectroscopy and gamma-ray imaging applications
    Fiorini, C
    Bellini, M
    Gola, A
    Longoni, A
    Perotti, F
    Lechner, P
    Soltau, H
    Strüder, L
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 1324 - 1326
  • [9] Silicon drift detectors for exotic atomsApplication for kaonic X-ray spectroscopy
    T. Ishiwatari
    Hyperfine Interactions, 2009, 194 : 165 - 170
  • [10] Silicon drift detectors with on-chip electronics for X-ray spectroscopy
    Politecnico di Milano, Milano, Italy
    J X Ray Sci Technol, 2 (117-129):