Comparison between Deff and Dw approaches for estimation of size-specific dose in paediatric CT imaging

被引:6
|
作者
Abdulkadir, Muhammad Kabir [1 ,2 ]
Shuaib, Ibrahim Lutfi [1 ]
Nasirudin, R. A. [1 ]
Samsudin, Ahmad Hadif Zaidin [3 ]
Osman, Noor Diyana [1 ,4 ]
机构
[1] Univ Sains Malaysia, Adv Med & Dent Inst, Bertam 13200, Penang, Malaysia
[2] Univ Ilorin, Fac Basic Clin Sci, Dept Med Radiog, Ilorin 240213, Nigeria
[3] Univ Sains Malaysia, Sch Med Sci, Dept Radiol, Kubang Kerian 16150, Kelantan, Malaysia
[4] Univ Sains Malaysia, Adv Med & Dent Inst, Oncol & Radiol Sci Cluster, Bertam 13200, Penang, Malaysia
关键词
Computed tomography; Size-specific dose estimate; Paediatric; Water-equivalent diameter; Effective diameter; ABDOMEN; CHEST; HEAD;
D O I
10.1016/j.radphyschem.2022.110205
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Individual patient size is an important determinant for size-specific dose estimate (SSDE) since the size correction factors are highly dependent on this factor. This study aims to compare two approaches for patient size measurement, the effective diameter (Deff) and water-equivalent diameter (Dw) for estimation of paediatric SSDE. The individual size of 318 paediatric patients (160 head and 158 abdomen CT) aged 0-12 years were measured retrospectively. The patient size was estimated using attenuation-based; Dw approach and geometry-based; Deff approach using anteroposterior (AP) and lateral dimensions on CT axial images. A comparative study was performed to determine the difference and association between these two approaches and their effects on SSDE. The measured patient size using Dw was higher than Deff by an average difference of about 12.8% and 9.3% for head and abdomen, respectively. There were high positive correlations between both approaches, head (R2 = 0.9176) and abdomen (R2 = 0.9491). The difference between measured Dw and Deff were observed by the Bland-Altman's analysis that showed good agreement between Dw and Deff. The overall disparity in SSDE calculated using Deff and Dw was less than 10%. The disparity was higher in head CT SSDE as compared to abdomen CT SSDE, due to lesser correlation between Dw and Deff in head CT scan. Our findings show Deff and Dw to be comparable size metrics for size-specific dose estimate in paediatric CT. The discrepancy between both dose metrics led to slight difference in SSDE calculated using Deff and Dw.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Attenuation-based estimation of patient size for the purpose of size specific dose estimation in CT. Part I. Development and validation of methods using the CT image
    Wang, Jia
    Duan, Xinhui
    Christner, Jodie A.
    Leng, Shuai
    Yu, Lifeng
    McCollough, Cynthia H.
    MEDICAL PHYSICS, 2012, 39 (11) : 6764 - 6771
  • [42] PATIENT DOSE SURVEY BASED ON SIZE-SPECIFIC DOSE ESTIMATE AND ACCEPTABLE QUALITY DOSE IN CHEST AND ABDOMEN/PELVIS CT EXAMINATIONS
    Mehdipour, Ali
    Parsi, Masoumeh
    Khorram, Faezeh-Sadat
    RADIATION PROTECTION DOSIMETRY, 2019, 185 (02) : 176 - 182
  • [43] How to Appropriately Calculate Effective Dose for CT Using Either Size-Specific Dose Estimates or Dose-Length Product
    Brady, Samuel L.
    Mirro, Amy E.
    Moore, Bria M.
    Kaufman, Robert A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (05) : 953 - 958
  • [44] PATIENTS DOSE ESTIMATION IN CT EXAMINATIONS USING SIZE SPECIFIC DOSE ESTIMATES
    Choudhary, Neha
    Rana, Bhupendra Singh
    Shukla, Arvind
    Oinam, Arun Singh
    Singh, Narinder Paul
    Kumar, Sanjeev
    RADIATION PROTECTION DOSIMETRY, 2019, 184 (02) : 256 - 262
  • [45] Calculation of scan length and size-specific dose at longitudinal positions of body CT scans using dose equilibrium function
    Li, Xinhua
    Marschall, Theodore A.
    Yang, Kai
    Liu, Bob
    MEDICAL PHYSICS, 2023, 50 (02) : 1096 - 1104
  • [46] How Inaccurate is Weight as a Metric for Patient Size? Comparing Patient Weight to Effective Diameter for Size-Specific Dose Estimation
    Cook, Tessa S.
    Chadalavada, Seetharam C.
    Boonn, William W.
    MEDICAL IMAGING 2013: ADVANCED PACS-BASED IMAGING INFORMATICS AND THERAPEUTIC APPLICATIONS, 2013, 8674
  • [47] Estimating a size-specific dose for helical head CT examinations using Monte Carlo simulation methods
    Hardy, Anthony J.
    Bostani, Maryam
    Hernandez, Andrew M.
    Zankl, Maria
    McCollough, Cynthia
    Cagnon, Chris
    Boone, John M.
    McNitt-Gray, Michael
    MEDICAL PHYSICS, 2019, 46 (02) : 902 - 912
  • [48] Size-specific dose estimations for pediatric chest, abdomen/pelvis and head CT scans with the use of GATE
    Kostou, Theodora
    Papadimitroulas, Panagiotis
    Papaconstadopoulos, Pavlos
    Devic, Slobodan
    Seuntjens, Jan
    Kagadis, George C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 65 : 181 - 190
  • [49] Sub-solid Nodule Detection performance on Reduced-dose Computed Tomography With lterative Reduction: Comparison Between 20 mA (7 mAs) and 120 mA (42 mAs) Regarding Nodular Size and Characteristics and Association with Size-specific Dose Estimate
    Nagatani, Yukihiro
    Takahashi, Masashi
    Ikeda, Mitsuru
    Yamashiro, Tsuneo
    Koyama, Hisanobu
    Koyama, Mitsuhiro
    Moriya, Hiroshi
    Noma, Satoshi
    Tomiyama, Noriyuki
    Ohno, Yoshiharu
    Murata, Kiyoshi
    Murayama, Sadayuki
    ACADEMIC RADIOLOGY, 2017, 24 (08) : 995 - 1007
  • [50] Size-specific dose estimates for pediatric head CT protocols based on the AAPM report TG-293
    Sapignoli, Sonia
    Roggio, Antonella
    Boschini, Alessio
    Guida, Federica
    Merlo, Carlo
    Paiusco, Marta
    Zorz, Alessandra
    De Monte, Francesca
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 100 : 26 - 30