Comparison between Deff and Dw approaches for estimation of size-specific dose in paediatric CT imaging

被引:6
|
作者
Abdulkadir, Muhammad Kabir [1 ,2 ]
Shuaib, Ibrahim Lutfi [1 ]
Nasirudin, R. A. [1 ]
Samsudin, Ahmad Hadif Zaidin [3 ]
Osman, Noor Diyana [1 ,4 ]
机构
[1] Univ Sains Malaysia, Adv Med & Dent Inst, Bertam 13200, Penang, Malaysia
[2] Univ Ilorin, Fac Basic Clin Sci, Dept Med Radiog, Ilorin 240213, Nigeria
[3] Univ Sains Malaysia, Sch Med Sci, Dept Radiol, Kubang Kerian 16150, Kelantan, Malaysia
[4] Univ Sains Malaysia, Adv Med & Dent Inst, Oncol & Radiol Sci Cluster, Bertam 13200, Penang, Malaysia
关键词
Computed tomography; Size-specific dose estimate; Paediatric; Water-equivalent diameter; Effective diameter; ABDOMEN; CHEST; HEAD;
D O I
10.1016/j.radphyschem.2022.110205
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Individual patient size is an important determinant for size-specific dose estimate (SSDE) since the size correction factors are highly dependent on this factor. This study aims to compare two approaches for patient size measurement, the effective diameter (Deff) and water-equivalent diameter (Dw) for estimation of paediatric SSDE. The individual size of 318 paediatric patients (160 head and 158 abdomen CT) aged 0-12 years were measured retrospectively. The patient size was estimated using attenuation-based; Dw approach and geometry-based; Deff approach using anteroposterior (AP) and lateral dimensions on CT axial images. A comparative study was performed to determine the difference and association between these two approaches and their effects on SSDE. The measured patient size using Dw was higher than Deff by an average difference of about 12.8% and 9.3% for head and abdomen, respectively. There were high positive correlations between both approaches, head (R2 = 0.9176) and abdomen (R2 = 0.9491). The difference between measured Dw and Deff were observed by the Bland-Altman's analysis that showed good agreement between Dw and Deff. The overall disparity in SSDE calculated using Deff and Dw was less than 10%. The disparity was higher in head CT SSDE as compared to abdomen CT SSDE, due to lesser correlation between Dw and Deff in head CT scan. Our findings show Deff and Dw to be comparable size metrics for size-specific dose estimate in paediatric CT. The discrepancy between both dose metrics led to slight difference in SSDE calculated using Deff and Dw.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Estimation of size-specific dose estimate (SSDE) of CT scans using an effective diameter electron density
    Almuqbil, Khuloud
    Abuhaimed, Abdullah
    Abanomy, Ahmed
    Alashban, Yazeed
    Alhawas, Abdulrahman
    Martin, Colin J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 172
  • [32] CNN application for automated determination of the patient's size to obtain the size-specific dose estimated in CT
    Hernandez-Davila, Erik R.
    Torres-Garcia, Eugenio
    Aranda-Lara, Liliana
    Roldan-Valadez, Ernesto
    Isaac-Olive, Keila
    Flores-Reyes, Mario
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (03)
  • [33] Radiation dose in chest CT: Assessment of size-specific dose estimates based on water-equivalent correction
    Gabusi, M.
    Riccardi, L.
    Aliberti, C.
    Vio, S.
    Paiusco, M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 393 - 397
  • [34] RADIATION DOSE DETERMINATION IN ABDOMINAL CT EXAMINATIONS OF CHILDREN AT SUDANESE HOSPITALS USING SIZE-SPECIFIC DOSE ESTIMATES
    Bashier, Einas H.
    Suliman, I. I.
    RADIATION PROTECTION DOSIMETRY, 2019, 183 (04) : 444 - 449
  • [35] Size-specific dose estimates in pediatric brain CT in relation to age and weight
    Fujii, Kaoru
    Inoue, Yusuke
    Itoh, Hiroyasu
    Sasa, Ryosuke
    Hata, Hirofumi
    Mitsui, Kohei
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (10) : 1075 - 1081
  • [36] Size-Specific Dose Estimates for Evaluation of Individual Patient Dose in CT Protocol for Renal Colic
    Waszczuk, Lukasz A.
    Guzinski, Maciej
    Czarnecka, Anna
    Sasiadek, Marek J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (01) : 100 - 105
  • [37] Variations in size-specific effective dose with patient stature and beam width for kV cone beam CT imaging in radiotherapy
    Martin, C. J.
    Abuhaimed, A.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (03)
  • [38] Size-Specific Dose Estimate (SSDE) Provides a Simple Method to Calculate Organ Dose for Pediatric CT Examinations
    Moore, B.
    Brady, S.
    Mirro, A.
    Kaufman, R.
    MEDICAL PHYSICS, 2014, 41 (06) : 424 - +
  • [39] Relationship between size-specific dose estimates and image quality in computed tomography depending on patient size
    Kawashima, Hiroki
    Ichikawa, Katsuhiro
    Hanaoka, Shinsuke
    Matsubara, Kosuke
    Takata, Tadanori
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 246 - 251
  • [40] Body physical parameters instead of water equivalent diameter to calculate size-specific dose estimate in adult chest CT
    Hu, Xiaoyan
    Gou, Jie
    Yang, Fan
    Guo, Dajing
    SCIENTIFIC REPORTS, 2024, 14 (01):