Detection of male genital infection with Chlamydia trachomatis and Neisseria gonorrhoeae using an automated multiplex PCR system (Cobas® Amplicor™)

被引:15
|
作者
Higgins, SP [1 ]
Klapper, PE [1 ]
Struthers, JK [1 ]
Bailey, AS [1 ]
Gough, AP [1 ]
Moore, R [1 ]
Corbitt, G [1 ]
Bhattacharyya, MN [1 ]
机构
[1] Manchester Royal Infirm, Dept Genitourinary Med, Manchester M13 9WL, Lancs, England
关键词
Chlamydia trachomatis; Neisseria gonorrhoeae; Cobas Amplicor PCR assay; urogenital samples; male;
D O I
10.1258/0956462981920982
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
We evaluated Cobas(R) Amplicor(TM), a highly automated polymerase chain reaction (PCR) system, to test first-void urine (FVU) and urethral swab specimens for Chlamydia trachomatis and Neisseria gonorrhoeae in men attending a sexually transmitted infection (STI) clinic. Results were compared against an inhouse radioimmune dot blot (DB) test for C, trachomatis and selective culture for N. gonorrhoeae. Three hundred and ninety sets of specimens were obtained from 378 consecutive new and returned-new patients. Gonorrhoea prevalence was 9.49%, with no significant difference in sensitivity or specificity between culture and PCR. Chlamydia prevalence was 15.4%, with sensitivities of: DB 55%, PCR of FVU 86.7%, urethral swab PCR 90%. The specificity of PCR on FVU and urethral swabs was 100%. We have shown that Cobas(R) Amplicor(TM) PCR is highly sensitive and specific in the diagnosis of chlamydia and gonorrhoea in men attending an STI clinic. Further economic and scientific studies are needed to determine the cost-effectiveness of this technique for screening in primary care settings.
引用
收藏
页码:21 / 24
页数:4
相关论文
共 35 条
  • [21] DETECTION OF CHLAMYDIA TRACHOMATIS AND NEISSERIA GONORRHOEAE IN UROGENITAL AND ORAL SPECIMENS USING THE COBAS (R) 4800, APTIMA COMBO 2 (R) TMA, AND PROBETECTM ET SDA ASSAYS
    Kumamoto, Y.
    Matsumoto, T.
    Fujisawa, M.
    Arakawa, S.
    EUROPEAN JOURNAL OF MICROBIOLOGY AND IMMUNOLOGY, 2012, 2 (02): : 121 - 127
  • [22] Performance assessment of the Allplex™ STI Essential real-time PCR assay for the diagnosis of Neisseria gonorrhoeae and Chlamydia trachomatis infections in genital and extra-genital sites
    Robinet, Sylvain
    Parisot, Francois
    JOURNAL OF LABORATORY MEDICINE, 2019, 43 (04) : 191 - 200
  • [23] High-volume workflow and performance comparisons for Chlamydia trachomatis and Neisseria gonorrhoeae testing using automated molecular platforms
    Frontzek, Andre
    Aretzweiler, Gudrun
    Winkens, Daniela
    Duncan, Dana
    Marlowe, Elizabeth M.
    BMC INFECTIOUS DISEASES, 2019, 19 (01)
  • [24] Time-Motion Analysis of Four Automated Systems for the Detection of Chlamydia trachomatis and Neisseria gonorrhoeae by Nucleic Acid Amplification Testing
    Williams, James A.
    Eddleman, Laura
    Pantone, Amy
    Martinez, Regina
    Young, Stephen
    Van der Pol, Barbara
    JALA, 2014, 19 (04): : 423 - 426
  • [25] Comparison of the Becton Dickinson strand displacement amplification and Cobas Amplicor Roche PCR for the detection of Chlamydia trachomatis:: pooling versus individual tests
    Bang, D
    Angelso, L
    Schirakow, B
    Westh, H
    CLINICAL MICROBIOLOGY AND INFECTION, 2003, 9 (10) : 1020 - 1023
  • [26] Detection of Neisseria gonorrhoeae or Chlamydia trachomatis from oral wash specimens using the Abbott RealTime CT/NG assay and the Cobas 4800 CT/NG assay: A prospective study
    Matsumoto, Masahiro
    Hamasuna, Ryoichi
    Le, Phuong Thi
    Fujimoto, Naohiro
    Matsumoto, Tetsuro
    JOURNAL OF INFECTION AND CHEMOTHERAPY, 2022, 28 (04) : 480 - 485
  • [27] Comparison of an in-house real-time duplex PCR assay with commercial HOLOGIC® APTIMA assays for the detection of Neisseria gonorrhoeae and Chlamydia trachomatis in urine and extra-genital specimens
    Venter, Johanna M. E.
    Mahlangu, Precious M.
    Mueller, Etienne E.
    Lewis, David A.
    Rebe, Kevin
    Struthers, Helen
    McIntyre, James
    Kularatne, Ranmini S.
    BMC INFECTIOUS DISEASES, 2019, 19 (1)
  • [28] Value of repeat testing using Cepheid GeneXpert CT/NG for indeterminate PCR results when diagnosing Chlamydia trachomatis and Neisseria gonorrhoeae
    Parcell, Benjamin J.
    Ratnayake, Lasantha
    Kaminski, Geraldine
    Olver, William J.
    Yirrell, David L.
    INTERNATIONAL JOURNAL OF STD & AIDS, 2015, 26 (01) : 65 - 67
  • [29] Evaluation of the APTIMA Combo 2 Assay using self-administered vaginal Swabs for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae
    Crucitti, Tania
    De Deken, Benedicte
    Smet, Hilde
    Cuylaerts, Vicky
    Abdellati, Said
    Vuylsteke, Bea
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2013, 76 (03) : 385 - 386
  • [30] Visual and rapid identification of Chlamydia trachomatis and Neisseria gonorrhoeae using multiplex loop-mediated isothermal amplification and a gold nanoparticle-based lateral flow biosensor
    Chen, Xu
    Zhou, Qingxue
    Yuan, Wei
    Shi, Yuanfang
    Dong, Shilei
    Luo, Xinhua
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2023, 13