Fluorescence-based optical sensor design for molecularly imprinted polymers

被引:38
作者
Chen, YC
Brazier, JJ
Yan, MD
Bargo, PR
Prahl, SA [1 ]
机构
[1] Oregon Hlth & Sci Univ, Dept Biomed Engn, Portland, OR 97225 USA
[2] Portland State Univ, Dept Chem, Portland, OR 97207 USA
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2004年 / 102卷 / 01期
基金
美国国家卫生研究院;
关键词
fluorescence sensor; Monte Carlo model; imprinted polyurethane; anthracene;
D O I
10.1016/j.snb.2004.02.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A Monte Carlo model was developed to analyze the sensitivity and the performance of a fluorescence-based molecularly imprinted polymer (MIP) sensor. The MIP sensor consisted of highly cross-linked polyurethane containing anthracene binding sites coated on a transparent substrate. The optical properties of MlPs, the quantum yields of anthracene within MIPs, and the fluorescence of MlPs were measured. The rebinding capacity of the MIPs was about 1 mumol/g or roughly seven times binding rate of non-imprinted polymers. The MIP fluorescence emission at 404 nm was measured for thicknesses ranging from 100 to 2000 mum containing templated anthracene concentrations ranging from 60 to 600 ppm for excitation at 358 nm. The emission agreed with model predictions within 15%. This sensing system could only distinguish anthracene down to 15 ppm due to fluorescence from the polymer matrix. To make a fluorescence-based MIP sensor that is capable of detecting one part per billion analyte concentration with a 200 mum thick MIP film, our model suggests that imprinted polymers would need to have an absorption coefficient less than 0.001 cm(-1), or have a quantum yield 10(5) times lower than that of the analyte at the detection wavelength. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:107 / 116
页数:10
相关论文
共 35 条
  • [1] Modeling and design of a novel miniaturized integrated optical sensor for gyroscope systems
    Armenise, MN
    Passaro, VMN
    De Leonardis, F
    Armenise, M
    [J]. JOURNAL OF LIGHTWAVE TECHNOLOGY, 2001, 19 (10) : 1476 - 1494
  • [2] BERLMAN IB, 1971, HDB FLOURESENCE SPEC
  • [3] Solvent effect on absolute fluorescence quantum yield of rhodamine 6G determined using transient thermal lens technique
    Bindhu, CV
    Harilal, SS
    Nampoori, VPN
    Vallabhan, CPG
    [J]. MODERN PHYSICS LETTERS B, 1999, 13 (16): : 563 - 576
  • [4] Effect of the excitation source on the quantum-yield measurements of rhodamine B laser dye studied using thermal-lens technique
    Bindhu, CV
    Harilal, SS
    [J]. ANALYTICAL SCIENCES, 2001, 17 (01) : 141 - 144
  • [5] Brazier JJ, 2002, MATER RES SOC SYMP P, V723, P115
  • [6] Molecularly imprinted sensor layers for the detection of polycyclic aromatic hydrocarbons in water
    Dickert, FL
    Tortschanoff, M
    Bulst, WE
    Fischerauer, G
    [J]. ANALYTICAL CHEMISTRY, 1999, 71 (20) : 4559 - 4563
  • [7] Dickert FL, 2000, ADV MATER, V12, P311, DOI 10.1002/(SICI)1521-4095(200002)12:4<311::AID-ADMA311>3.0.CO
  • [8] 2-G
  • [9] Synthetic receptors as sensor coatings for molecules and living cells
    Dickert, FL
    Hayden, O
    Halikias, KP
    [J]. ANALYST, 2001, 126 (06) : 766 - 771
  • [10] Dickert FL, 1998, ADV MATER, V10, P149, DOI 10.1002/(SICI)1521-4095(199801)10:2<149::AID-ADMA149>3.0.CO