Prognostic Importance of Atrial Fibrillation in Implantable Cardioverter-Defibrillator Patients

被引:64
作者
Borleffs, C. Jan Willem [1 ]
van Rees, Johannes B. [1 ]
van Welsenes, Guido H. [1 ]
van der Velde, Enno T. [1 ]
van Erven, Lieselot [1 ]
Bax, Jeroen J. [1 ]
Schalij, Martin J. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, NL-2333 ZA Leiden, Netherlands
关键词
atrial fibrillation; implantable cardioverter-defibrillator; mortality; tachyarrhythmia; ventricular arrhythmia; CONGESTIVE-HEART-FAILURE; MYOCARDIAL-INFARCTION; APPROPRIATE SHOCKS; THERAPY; RISK; TACHYCARDIA; FIBRILATION; AMIODARONE;
D O I
10.1016/j.jacc.2009.09.053
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study aimed to assess the prevalence of different types of atrial fibrillation (AF) and their prognostic importance in implantable cardioverter-defibrillator (ICD) patients. Background The prevalence of AF has taken epidemic proportions in the population with cardiovascular disease. The prognostic importance of different types of AF in ICD patients remains unclear. Methods Data on 913 consecutive patients (79% men, mean age 62 +/- 13 years) receiving an ICD at the Leiden University Medical Center were prospectively collected. Among other characteristics, the existence and type of AF (paroxysmal, persistent, or permanent) were assessed at implantation. During follow-up, the occurrence of appropriate or inappropriate device therapy as well as mortality was noted. Results At implantation, 73% of patients had no history of AF, 9% had a history of paroxysmal AF, 7% had a history of persistent AF, and 11% had permanent AF. During 833 +/- 394 days of follow-up, 117 (13%) patients died, 228 (25%) patients experienced appropriate device discharge, and 139 (15%) patients received inappropriate shocks. Patients with permanent AF exhibited more than double the risk of mortality, ventricular arrhythmias triggering device discharge, and inappropriate device therapy. Patients with paroxysmal or persistent AF did not show a significant increased risk of mortality or appropriate device therapy but demonstrated almost 3 times the risk of inappropriate device therapy. Conclusions In the population currently receiving ICD treatment outside the setting of clinical trials, a large portion has either a history of AF or permanent AF. Both types of AF have prognostic implications for mortality and appropriate as well as inappropriate device discharge. (J Am Coll Cardiol 2010; 55: 879-85) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:879 / 885
页数:7
相关论文
共 36 条
[1]   Prognosis of congestive heart failure after prior myocardial infarction in older persons with atrial fibrillation versus sinus rhythm [J].
Aronow, WS ;
Ahn, C ;
Kronzon, I .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 87 (02) :224-+
[2]  
*AVID INV, 1997, NEW ENGL J MED, V337, P157
[3]  
Bardy GH, 2005, NEW ENGL J MED, V352, P2146
[4]   Impact of atrial fibrillation on the risk of death [J].
Benjamin, EJ ;
Wolf, PA ;
D'Agostino, RB ;
Silbershatz, H ;
Kannel, WB ;
Levy, D .
CIRCULATION, 1998, 98 (10) :946-952
[5]   Rhythm management in atrial fibrillation - With a primary emphasis on pharmacological therapy: Part 1 [J].
Blitzer, M ;
Costeas, C ;
Kassotis, J ;
Reiffel, JA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (03) :590-602
[6]  
Bonow RO, 2008, J AM COLL CARDIOL, V52, pE1, DOI [10.1016/j.hrthm.2008.04.014, 10.1016/j.jacc.2008.05.007]
[7]   Newly detected atrial fibrilation in patients with an implantable cardioverter-defibrillator is a strong risk marker of increased mortality [J].
Bunch, T. Jared ;
Day, John D. ;
Olshansky, Brian ;
Stolen, Kira Q. ;
Mullin, Christopher M. .
HEART RHYTHM, 2009, 6 (01) :2-8
[8]  
CARSON PE, 1993, CIRCULATION, V87, P102
[9]   Canadian implantable defibrillator study (CIDS) - A randomized trial of the implantable cardioverter defibrillator against amiodarone [J].
Connolly, SJ ;
Gent, M ;
Roberts, RS ;
Dorian, P ;
Roy, D ;
Sheldon, RS ;
Mitchell, LB ;
Green, MS ;
Klein, GJ ;
O'Brien, B .
CIRCULATION, 2000, 101 (11) :1297-1302
[10]   TORSADE-DE-POINTES AND OTHER PAUSE-INDUCED VENTRICULAR TACHYCARDIAS - THE SHORT-LONG-SHORT SEQUENCE AND EARLY AFTERDEPOLARIZATIONS [J].
CRANEFIELD, PF ;
ARONSON, RS .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (06) :670-678