共 24 条
Sensitivity of dynamic simulations of gait and dynamometer experiments to hill muscle model parameters of knee flexors and extensors
被引:77
作者:
De Groote, F.
[1
]
Van Campen, A.
[1
]
Junkers, I.
[2
]
De Schutter, J.
[1
]
机构:
[1] Katholieke Univ Leuven, Dept Mech Engn, Div PMA, B-3001 Heverlee, Belgium
[2] Katholieke Univ Leuven, Dept Biomed Kinesiol, B-3001 Heverlee, Belgium
关键词:
Sensitivity analysis;
Simulation;
Optimisation;
Subject-specific modelling;
Muscle-tendon properties;
MUSCULOSKELETAL MODEL;
ANGLE RELATIONSHIP;
LOWER-EXTREMITY;
RELIABILITY;
TENDON;
OPTIMIZATION;
KINEMATICS;
JOINT;
LIMB;
D O I:
10.1016/j.jbiomech.2010.03.022
中图分类号:
Q6 [生物物理学];
学科分类号:
071011 ;
摘要:
We assessed and compared sensitivities of dynamic simulations to musculotendon (MT) parameters for gait and dynamometer experiments. Our aim with this comparison was to investigate whether dynamometer experiments could provide information about MT-parameters that are important to reliably study MT-function during gait. This would mean that dynamometer experiments could be used to estimate these parameters. Muscle contribution to the joint torque (MT-torque) rather than relative MT-force primarily affects the resulting gait pattern and torque measured by the dynamometer. In contrast to recent studies, therefore, we assessed the sensitivity of the MT-torque, rather than the sensitivity of the relative MT-force. Based on sensitivity of the MT-torque to a parameter perturbation, MT-parameters of the knee flexors and extensors were classified in three categories: low, medium, and high. For gait, classification was based on the average sensitivity during a gait cycle. For isometric and isokinetic dynamometer experiments, classification was based on the highest sensitivity found in the experiments. The calculated muscle contributions to the knee torque during gait and dynamometer experiments had a high sensitivity to only a limited number of MT-parameters of the knee flexors and extensors, suggesting that not all MT-parameters need to be estimated. In general, the highest sensitivity was found for tendon slack length. However, for some muscles the sensitivity to the optimal fibre length or the maximal isometric muscle force was also high or medium. The classification of the individual MT-parameters for gait and dynamometer experiments was largely similar. We therefore conclude that dynamometer experiments provide information about MT-parameters important to reliably study MT-function during gait, so that subject-specific estimates of MT-parameters could be made based on dynamometer experiments. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1876 / 1883
页数:8
相关论文