A mediated polyphenol oxidase biosensor immobilized by electropolymerization of 1,2-diamino benzene

被引:21
作者
Akyilmaz, Erol [1 ]
Kozgus, Ozge [1 ]
Turkmen, Hayati [2 ]
Cetinkaya, Bekir [2 ]
机构
[1] Ege Univ, Fac Sci, Dept Biochem, TR-35100 Bornova, Turkey
[2] Ege Univ, Fac Sci, Dept Chem, TR-35100 Bornova, Turkey
关键词
Polyphenole oxidase; Biosensor; Catechol; Mediator; 1,2-diamino benzene; AMPEROMETRIC BIOSENSORS; ELECTRON-TRANSFER; GOLD NANOPARTICLES; ENZYME ELECTRODE; GLUCOSE-OXIDASE; TYROSINASE; FILMS; PEROXIDASE; COMPLEXES; COMPOSITE;
D O I
10.1016/j.bioelechem.2009.09.003
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A biosensor based on a partially purified polyphenol oxidase (PPO) enzyme was developed by using electropolymerization of [(2,2'-bipyridine)(chloro)(p-cymene)rutenium(II)]chloride] mediator complex and 1,2-diamino benzene (DAB) on a screen printing Pt electrode (1 mm diameter). The electropolymerization was carried out at +0.7 V for 45 min in phosphate buffer (50 mM, pH 7.0) which contained 14.0 U/10 mL polyphenole oxidase, 200 mM DAB and 2.5 mM Ru-mediator complex solutions. Measurement is based on the detection of the oxidation current of the Ru-mediator complex that related to the enzymatic reaction catalyzed by PPO at +0.65 V. The phosphate buffer (50 mM, pH 7.0 containing 0.1 M KCl) and 30 degrees C were established as being the optimum working conditions. Under the optimum experimental conditions a linear calibration curve was obtained between 5 and 100 mu M catechol concentration. The detection limit of the biosensor is 2.385 mu M. In the characterization studies of the biosensor some parameters such as effect of Ru-mediator types on the biosensor response, substrate specificity, reproducibility and storage stability were studied. From the experiments, the average value (x), standard deviation (SD) and coefficient of variation (CV%) were found to be 48.75 mu M, 1.56 mu M, and 3.2% respectively for 50 mu M catechol standard. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:135 / 140
页数:6
相关论文
共 37 条
[1]   Investigation of metal activation of a partially purified polyphenol oxidase enzyme electrode [J].
Akyilmaz, Erol ;
Baysal, Senay Hamarat ;
Dinckaya, Erhan .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2007, 87 (10-11) :755-761
[2]   Development of a high analytical performance-tyrosinase biosensor based on a composite graphite -: Teflon electrode modified with gold nanoparticles [J].
Carralero, V. ;
Mena, M. L. ;
Gonzalez-Cortes, A. ;
Yanez-Sedeno, P. ;
Pingarron, J. M. .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (05) :730-736
[3]   Application of electrosynthesized poly(aniline-co-p-aminophenol) as a catechol sensor [J].
Chen, Chuanxiang ;
Sun, Cheng ;
Gao, Yuhua .
ELECTROCHIMICA ACTA, 2009, 54 (09) :2575-2580
[4]   Amperometric tyrosinase biosensor based on Fe3O4 nanoparticles-coated carbon nanotubes nanocomposite for rapid detection of coliforms [J].
Cheng, Yuxiao ;
Liu, Yajun ;
Huang, Jingjing ;
Li, Kang ;
Xian, Yuezhong ;
Zhang, Wen ;
Jin, Litong .
ELECTROCHIMICA ACTA, 2009, 54 (09) :2588-2594
[5]   Physicochemical characterization of the layer-by-layer self-assembly of polyphenol oxidase and chitosan on glassy carbon electrode [J].
Coche-Guérente, L ;
Desbrières, J ;
Fatisson, J ;
Labbé, P ;
Rodriguez, MC ;
Rivas, G .
ELECTROCHIMICA ACTA, 2005, 50 (14) :2865-2877
[6]   Mediated electrochemical detection of catechol by tyrosinase-based poly(dicarbazole) electrodes [J].
Cosnier, S ;
Szunerits, S ;
Marks, RS ;
Lellouche, JP ;
Perie, K .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2001, 50 (01) :65-77
[7]   Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review [J].
Cosnier, S .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :443-456
[8]   Organic phase PPO biosensor based on hydrophilic films of electropolymerized polypyrrole [J].
Cristea, C ;
Mousty, C ;
Cosnier, S ;
Popescu, IC .
ELECTROCHIMICA ACTA, 2005, 50 (18) :3713-3718
[9]   A new interference-free lysine biosensor using a non-conducting polymer film [J].
Curulli, A ;
Kelly, S ;
O'Sullivan, C ;
Guilbault, GG ;
Palleschi, G .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (12) :1245-1250
[10]   Flow-injection determination of catechol with a new tyrosinase/DNA biosensor [J].
Dantoni, P ;
Serrano, SHP ;
Brett, AMO ;
Gutz, IGR .
ANALYTICA CHIMICA ACTA, 1998, 366 (1-3) :137-145