A facility for electrical contact resistance measurement

被引:8
作者
Maheshappa, HD [1 ]
Nagaraju, J [1 ]
KrishnaMurthy, MV [1 ]
机构
[1] Indian Inst Sci, Dept Instrumentat, Bangalore 560012, Karnataka, India
关键词
D O I
10.1063/1.1148810
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A test facility was developed for directly measuring the electrical contact resistance of switch gear contacts of real sizes under different environmental conditions and contact pressures. It can measure contact resistance to an order of one-tenth of a mu Omega. It sources a constant current in the order of mA and hence avoids Initial arcing across contacts, Experiments were conducted on brass-brass samples with different contact pressures and the results are in agreement with published theoretical calculations. (C) 1998 American Institute of Physics.
引用
收藏
页码:1534 / 1536
页数:3
相关论文
共 5 条
  • [1] BRAUNOVIC M, 1986, IEEE T COMPON HYBR, V8, P313
  • [2] Holm R., 1981, Electrical Contacts, VFourth
  • [3] MATERIALS AND CONTACT SHAPE STUDIES FOR AUTOMOBILE CONNECTORS DEVELOPMENT
    QUEFFELEC, JL
    BENJEMAA, N
    TRAVERS, D
    PETHIEU, G
    [J]. IEEE TRANSACTIONS ON COMPONENTS HYBRIDS AND MANUFACTURING TECHNOLOGY, 1991, 14 (01): : 90 - 94
  • [4] A simple apparatus for measuring electrical resistance of materials at high temperatures
    Rao, GVN
    Sastry, VS
    Radhakrishnan, TS
    Seshagiri, V
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (01) : 333 - 334
  • [5] TAMAI T, 1986, IEEE T COMPON HYBR, V9, P41