Synthesis of a mixed-model stationary phase derived from glutamine for HPLC separation of structurally different biologically active compounds: HILIC and reversed-phase applications

被引:50
作者
Aral, Tarik [1 ]
Aral, Hayriye [1 ]
Ziyadanogullari, Berrin [2 ]
Ziyadanogullari, Recep [2 ]
机构
[1] Univ Batman, Fac Sci & Art, Dept Chem, Batman, Turkey
[2] Dicle Univ, Fac Sci, Dept Chem, Diyarbakir, Turkey
关键词
Mixed-model stationary phase; Polar stationary phase; Nucleotides and nucleosides; Phytohormones; Phenolic compounds; HILIC; HYDROPHILIC-INTERACTION CHROMATOGRAPHY; POLYBUTADIENE-COATED ZIRCONIA; SMALL POLAR COMPOUNDS; LIQUID-CHROMATOGRAPHY; EXCHANGE CHROMATOGRAPHY; RETENTION BEHAVIOR; SILICA COLUMNS; PERFORMANCE; PEPTIDES; AMIDE;
D O I
10.1016/j.talanta.2014.07.060
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel mixed-mode stationary phase was synthesised starting from N-Boc-glutamine, aniline and spherical silica gel (4 mu m, 60 angstrom). The prepared stationary phase was characterized by IR and elemental analysis. The new stationary phase bears an embedded amide group into phenyl ring, highly polar a terminal amide group and non-polar groups (phenyl and alkyl groups). At first, this new mixed-mode stationary phase was used for HILIC separation of four nucleotides and five nucleosides. The effects of different separation conditions, such as pH value, mobile phase and temperature, on the separation process were investigated. The optimum separation for nucleotides was achieved using HILIC isocratic elution with aqueous mobile phase and acetonitrile with 20 degrees C column temperature. Under these conditions, the four nucleotides could be separated and detected at 265 nm within 14 min. Five nucleosides were separated under HILIC isocratic elution with aqueous mobile phase containing pH=3.25 phosphate buffer (10 mM) and acetonitrile with 20 degrees C column temperature and detected at 265 nm within 14 min. Chromatographic parameters as retention factor, selectivity, theoretical plate number and peak asymmetry factor were calculated for the effect of temperature and water content in mobile phase on the separation process. The new column was also tested for nucleotides and nucleosides mixture and six analytes were separated in 10 min. The chromatographic behaviours of these polar analytes on the new mixed-model stationary phase were compared with those of HILIC columns under similar conditions. Further, phytohormones and phenolic compounds were separated in order to see influence of the new stationary phase in reverse phase conditions. Eleven plant phytohormones were separated within 13 min using RP-HPLC gradient elution with aqueous mobile phase containing pH=2.5 phosphate buffer (10 mM) and acetonitrile with 20 degrees C column temperature and detected at 230 or 278 nm. The best separation conditions for seven phenolic compounds was also achieved using reversed-phase HPLC gradient elution with aqueous mobile phase containing pH=2.5 phosphate buffer (10 mM) and acetonitrile with 20 degrees C column temperature and seven phenolic compounds could be separated and detected at 230 nm within 16 min. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:64 / 73
页数:10
相关论文
共 33 条
[1]   HYDROPHILIC-INTERACTION CHROMATOGRAPHY OF COMPLEX CARBOHYDRATES [J].
ALPERT, AJ ;
SHUKLA, M ;
SHUKLA, AK ;
ZIESKE, LR ;
YUEN, SW ;
FERGUSON, MAJ ;
MEHLERT, A ;
PAULY, M ;
ORLANDO, R .
JOURNAL OF CHROMATOGRAPHY A, 1994, 676 (01) :191-202
[2]  
Alpert AJ, 2006, ADV CHROMATOGR, V44, P317
[3]   HPLC Separation of Different Groups of Small Polar Compounds on a Novel Amide-Embedded Stationary Phase [J].
Aral, Hayriye ;
Aral, Tarik ;
Celik, K. Serdar ;
Ziyadanogullari, Berrin ;
Ziyadanogullari, Recep .
CHROMATOGRAPHIA, 2014, 77 (11-12) :771-781
[4]   Development of a novel amide-silica stationary phase for the reversed-phase HPLC separation of different classes of phytohormones [J].
Aral, Hayriye ;
Aral, Tarik ;
Ziyadanogullari, Berrin ;
Ziyadanogullari, Recep .
TALANTA, 2013, 116 :155-163
[5]   Characterization and high performance liquid chromatographic evaluation of a new amide-functionalized reversed phase column [J].
Ascah, TL ;
Kallury, KMR ;
Szafranski, CA ;
Corman, SD ;
Liu, F .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1996, 19 (17-18) :3049-3073
[6]   Hydrophilic interaction liquid chromatography (HILIC)-a powerful separation technique [J].
Buszewski, Boguslaw ;
Noga, Sylwia .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (01) :231-247
[7]   Recent progress in carbohydrate separation by high-performance liquid chromatography based on hydrophilic interaction [J].
Churms, SC .
JOURNAL OF CHROMATOGRAPHY A, 1996, 720 (1-2) :75-91
[8]   SEPARATION OF GLUCOOLIGOSACCHARIDES AND POLYSACCHARIDE HYDROLYSATES BY GRADIENT ELUTION HYDROPHILIC INTERACTION CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION [J].
FESTE, AS ;
KHAN, I .
JOURNAL OF CHROMATOGRAPHY, 1993, 630 (1-2) :129-139
[9]  
Gama M.R., 2012, TRENDS ANAL CHEM
[10]   Synthesis of Lactose-Containing Glycopolymer-Grafted Silica Gel Particles [J].
Guo, Tian-Ying ;
Liu, Ping ;
Xia, Yong-Qing ;
Song, Mou-Dao .
JOURNAL OF APPLIED POLYMER SCIENCE, 2010, 116 (03) :1611-1616