A proton imaging device: Design and status of realization

被引:30
作者
Sipala, V. [1 ,2 ]
Bruzzi, M. [4 ,5 ]
Bucciolini, M. [3 ,4 ]
Candiano, G. [7 ]
Capineri, L. [6 ]
Cirrone, G. A. P. [7 ]
Civinini, C. [4 ]
Cuttone, G. [7 ]
Lo Presti, D. [1 ,2 ]
Marrazzo, L. [3 ,4 ]
Mazzaglia, E. [7 ]
Menichelli, D. [4 ,5 ]
Randazzo, N. [1 ]
Talamonti, C. [3 ,4 ]
Valentini, S. [4 ,6 ]
机构
[1] Ist Nazl Fis Nucl, Sez Catania, I-95123 Catania, Italy
[2] Univ Catania, Dipartimento Fis, I-95123 Catania, Italy
[3] Univ Florence, Dipartimento Fisiopatol Clin, I-50134 Florence, Italy
[4] Ist Nazl Fis Nucl, Sez Firenze, I-50019 Sesto Fiorentino, FI, Italy
[5] Univ Florence, Dipartimento Energet, I-50139 Florence, Italy
[6] Univ Florence, Dipartimento Elettron & Telecomunicaz, I-50139 Florence, Italy
[7] Ist Nazl Fis Nucl, Lab Nazl Sud, I-95123 Catania, Italy
关键词
Proton therapy; Proton imaging; Silicon tracker; Proton calorimetry;
D O I
10.1016/j.nima.2009.08.029
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Proton radiation therapy is a precise form of cancer therapy, which requires verification of the patient position and the accurate knowledge of the dose delivered to the patient. At present in the proton treatment centre, patients are positioned with X-ray radiography and dose calculations rely on the patient's morphology and electron densities obtained by X-ray computed tomography [U. Schneider, E. Pedroni, Med. Phys. 22 (1995) 353]. A proton imaging device can improve the accuracy of proton radiation therapy treatment planning and the alignment of the patient with the proton beam. Our collaboration has developed a pCR prototype consisting of a silicon microstrip tracker and a calorimeter to detect the residual energy [R. Shulte, et al., IEEE Trans. Nucl. Sci. 51 (2004) 866-872]. In this contribution we will show some results obtained testing the front-end board of the tracker and measurements performed at LNS (Laboratori Nazionali del Sud) and in LLUMC (Loma Linda University Medical Centre) using 60 and 200 MeV proton beams to test the calorimeter. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:566 / 570
页数:5
相关论文
共 6 条
[1]   The Italian project for a proton imaging device [J].
Cirrone, G. A. P. ;
Candiano, G. ;
Cuttone, G. ;
Lo Nigro, S. ;
Lo Presti, D. ;
Randazzo, N. ;
Sipala, V. ;
Russo, M. ;
Aiello, S. ;
Bruzzi, M. ;
Menichelli, D. ;
Secringella, M. ;
Miglio, S. ;
Bucciolini, M. ;
Talamonti, C. ;
Pallotta, S. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01) :194-197
[2]   PROSPECTS OF CSI(T1) PHOTODIODE DETECTORS FOR LOW-LEVEL SPECTROSCOPY [J].
KILGUS, U ;
KOTTHAUS, R ;
LANGE, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (03) :425-440
[3]   YAP(Ce) crystal characterization with proton beam up to 60 MeV [J].
Randazzo, N. ;
Sipala, V. ;
Alello, S. ;
Lo Presti, D. ;
Cirrone, G. A. P. ;
Cuttone, G. ;
Di Rosa, F. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 586 (02) :295-299
[4]   Residual energy measurements for proton Computed Tomography [J].
Randazzo, Nunzio ;
Sipala, Valeria ;
Lo Presti, Domenico ;
Cirrone, G. A. Pablo ;
Cottone, Giacomo ;
Di Rosa, Francesco ;
Bashkirov, Vladimir ;
Schulte, Reinhard .
2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, :1643-+
[5]   Issues in proton computed tomography [J].
Sadrozinski, HFW ;
Bashkirov, V ;
Bruzzi, M ;
Johnson, LR ;
Keeney, B ;
Ross, G ;
Schulte, RW ;
Seiden, A ;
Shahnazi, K ;
Williams, DC ;
Zhang, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 511 (1-2) :275-281
[6]   Density resolution of proton computed tomography [J].
Schulte, RW ;
Bashkirov, V ;
Klock, MCL ;
Li, TF ;
Wroe, AJ ;
Evseev, I ;
Williams, DC ;
Satogata, T .
MEDICAL PHYSICS, 2005, 32 (04) :1035-1046