2D cine vs. 3D self-navigated free-breathing high-resolution whole heart cardiovascular magnetic resonance for aortic root measurements in congenital heart disease

被引:13
|
作者
Nussbaumer, Clement [1 ,2 ]
Bouchardy, Judith [2 ,3 ]
Blanche, Coralie [1 ,2 ]
Piccini, Davide [2 ,4 ,5 ]
Pavon, Anna-Giulia [1 ,2 ]
Monney, Pierre [1 ,2 ]
Stuber, Matthias [2 ,4 ]
Schwitter, Jurg [1 ,2 ]
Rutz, Tobias [1 ,2 ,3 ]
机构
[1] Lausanne Univ Hosp, Ctr Resonance Magnet Cardiaque, Serv Cardiol, Lausanne, Switzerland
[2] Univ Lausanne, Lausanne, Switzerland
[3] Lausanne Univ Hosp, Adult Congenital Heart Dis Unit, Serv Cardiol, Lausanne, Switzerland
[4] Univ Hosp, Dept Radiol, Lausanne, Switzerland
[5] Siemens Healthcare AG, Adv Clin Imaging Technol, Lausanne, Switzerland
关键词
Aortic root dilatation; 3D self-navigation whole heart; Congenital heart disease; Bicuspid aortic valve; ENHANCED MR-ANGIOGRAPHY; EUROPEAN ASSOCIATION; AMERICAN SOCIETY; TURNER SYNDROME; IMAGE QUALITY; CORONARY MRA; BLACK BLOOD; ADULTS; DISSECTION; SSFP;
D O I
10.1186/s12968-021-00744-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Cardiovascular magnetic resonance (CMR) is considered the method of choice for evaluation of aortic root dilatation in congenital heart disease. Usually, a cross-sectional 2D cine stack is acquired perpendicular to the vessel's axis. However, this method requires a considerable patient collaboration and precise planning of image planes. The present study compares a recently introduced 3D self-navigated free-breathing high-resolution whole heart CMR sequence (3D self nav) allowing a multiplanar retrospective reconstruction of the aortic root as an alternative to the 2D cine technique for determination of aortic root diameters. Methods A total of 6 cusp-commissure (CuCo) and cusp-cusp (CuCu) enddiastolic diameters were measured by two observers on 2D cine and 3D self nav cross-sectional planes of the aortic root acquired on a 1.5 T CMR scanner. Asymmetry of the aortic root was evaluated by the ratio of the minimal to the maximum 3D self nav CuCu diameter. CuCu diameters were compared to standard transthoracic echocardiographic (TTE) aortic root diameters. Results Sixty-five exams in 58 patients (32 +/- 15 years) were included. Typically, 2D cine and 3D self nav spatial resolution was 1.1-1.5(2) x 4.5-7 mm and 0.9-1.15(3) mm, respectively. 3D self nav yielded larger maximum diameters than 2D cine: CuCo 37.2 +/- 6.4 vs. 36.2 +/- 7.0 mm (p = 0.006), CuCu 39.7 +/- 6.3 vs. 38.5 +/- 6.5 mm (p < 0.001). CuCu diameters were significantly larger (2.3-3.9 mm, p < 0.001) than CuCo and TTE diameters on both 2D cine and 3D self nav. Intra- and interobserver variabilities were excellent for both techniques with bias of -0.5 to 1.0 mm. Intra-observer variability of the more experienced observer was better for 3D self nav (F-test p < 0.05). Aortic root asymmetry was more pronounced in patients with bicuspid aortic valve (BAV: 0.73 (interquartile (IQ) 0.69; 0.78) vs. 0.93 (IQ 0.9; 0.96), p < 0.001), which was associated to a larger difference of maximum CuCu to TTE diameters: 5.5 +/- 3.3 vs. 3.3 +/- 3.8 mm, p = 0.033. Conclusion Both, the 3D self nav and 2D cine CMR techniques allow reliable determination of aortic root diameters. However, we propose to privilege the 3D self nav technique and measurement of CuCu diameters to avoid underestimation of the maximum diameter, particularly in patients with asymmetric aortic roots and/or BAV.
引用
收藏
页数:12
相关论文
共 27 条
  • [1] 2D cine vs. 3D self-navigated free-breathing high-resolution whole heart cardiovascular magnetic resonance for aortic root measurements in congenital heart disease
    Clément Nussbaumer
    Judith Bouchardy
    Coralie Blanche
    Davide Piccini
    Anna-Giulia Pavon
    Pierre Monney
    Matthias Stuber
    Jürg Schwitter
    Tobias Rutz
    Journal of Cardiovascular Magnetic Resonance, 23
  • [2] Coronary artery assessment using self-navigated free-breathing radial whole-heart magnetic resonance angiography in patients with congenital heart disease
    Albrecht, Moritz H.
    Varga-Szemes, Akos
    Schoepf, U. Joseph
    Apfaltrer, Georg
    Xu, Jiaqian
    Jin, Kwang-Nam
    Hlavacek, Anthony M.
    Chowdhury, Shahryar M.
    Suranyi, Pal
    Tesche, Christian
    De Cecco, Carlo N.
    Piccini, Davide
    Stuber, Matthias
    Ginami, Giulia
    Vogl, Thomas J.
    Nutting, Arni
    EUROPEAN RADIOLOGY, 2018, 28 (03) : 1267 - 1275
  • [3] Self-navigated free-breathing isotropic 3D whole heart MRI for the characterization of complex cardiac anatomy in patients with congenital heart malformations
    Pierre Monney
    Davide Piccini
    Gabriella Vincenti
    Arne Littmann
    Michael O Zenge
    Simon C Koestner
    Matthias Stuber
    Juerg Schwitter
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [4] Coronary artery assessment using self-navigated free-breathing radial whole-heart magnetic resonance angiography in patients with congenital heart disease
    Moritz H. Albrecht
    Akos Varga-Szemes
    U. Joseph Schoepf
    Georg Apfaltrer
    Jiaqian Xu
    Kwang-Nam Jin
    Anthony M. Hlavacek
    Shahryar M. Chowdhury
    Pal Suranyi
    Christian Tesche
    Carlo N. De Cecco
    Davide Piccini
    Matthias Stuber
    Giulia Ginami
    Thomas J. Vogl
    Arni Nutting
    European Radiology, 2018, 28 : 1267 - 1275
  • [5] Whole heart self-navigated 3D radial MRI for the creation of virtual 3D models in congenital heart disease
    Nicole Wake
    Li Feng
    Davide Piccini
    Larry A Latson
    Ralph S Mosca
    Daniel K Sodickson
    Puneet Bhatla
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [6] Non-contrast free-breathing whole-heart 3D cine cardiovascular magnetic resonance with a novel 3D radial leaf trajectory
    Braunstorfer, Lukas
    Romanowicz, Jennifer
    Powell, Andrew J.
    Pattee, Jack
    Browne, Lorna P.
    van der Geest, Rob J.
    Moghari, Mehdi H.
    MAGNETIC RESONANCE IMAGING, 2022, 94 : 64 - 72
  • [7] Free-breathing whole-heart 3D cine magnetic resonance imaging with prospective respiratory motion compensation
    Moghari, Mehdi H.
    Barthur, Ashita
    Amaral, Maria E.
    Geva, Tal
    Powell, Andrew J.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (01) : 181 - 189
  • [8] Single centre experience of the application of self navigated 3D whole heart cardiovascular magnetic resonance for the assessment of cardiac anatomy in congenital heart disease
    Monney, Pierre
    Piccini, Davide
    Rutz, Tobias
    Vincenti, Gabriella
    Coppo, Simone
    Koestner, Simon C.
    Sekarski, Nicole
    Di Bernardo, Stefano
    Bouchardy, Judith
    Stuber, Matthias
    Schwitter, Juerg
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [9] Single centre experience of the application of self navigated 3D whole heart cardiovascular magnetic resonance for the assessment of cardiac anatomy in congenital heart disease
    Pierre Monney
    Davide Piccini
    Tobias Rutz
    Gabriella Vincenti
    Simone Coppo
    Simon C. Koestner
    Nicole Sekarski
    Stefano Di Bernardo
    Judith Bouchardy
    Matthias Stuber
    Juerg Schwitter
    Journal of Cardiovascular Magnetic Resonance, 17
  • [10] Accelerated high-resolution free-breathing 3D whole-heart T2-prepared black-blood and bright-blood cardiovascular magnetic resonance
    Teresa Correia
    Giulia Ginami
    Imran Rashid
    Giovanna Nordio
    Reza Hajhosseiny
    Tevfik F. Ismail
    Radhouene Neji
    René M. Botnar
    Claudia Prieto
    Journal of Cardiovascular Magnetic Resonance, 22