Effects of leukocyte depletion on the quality of stored whole blood

被引:0
|
作者
Neumeister, B
Grauer, M
Koch, M
Hornlein, R
Dinkelmann, S
Bernhard, R
Haap, M
Northoff, H
机构
[1] Univ Klimikums Tubingen, Klin Anasthesiol & Transfus Med, Abt Transfus Med, Tubingen, Germany
[2] Univ Klinikums Tubingen, Klin Anasthesiol & Transfus Med, Blutbank, Tubingen, Germany
[3] Univ Klinikum Tubingen, Zentrallabor Med Klin, Tubingen, Germany
来源
ANAESTHESIST | 1997年 / 46卷 / 11期
关键词
autologous blood donations; whole blood; leukocyte depletion; storage quality;
D O I
10.1007/s001010050496
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: According to the German Guidelines for Hemotherapy, preoperative autologous blood donations can be stored and transfused as whole blood. In contrast to the storage of blood components, however, storage of whole blood results in deterioration of the biological quality due to contamination with leukocytes and platelets. In this study we examined the influence ai prestorage leukocyte depletion on the duality of Filtered whole blood donations during storage, Material and Methods: Whole blood was donated by healthy volunteers (n=14,500 mi, 70 mi CPDA-1) and was filtered using an integrated whole blood filter system (Leukotrap Al, Fa.Pall, Dreieich, Germany). The leukocyte-depleted whole blood units were then stored for up to 49 days, Several hematological and biochemical parameters indicative of the quality of blood donations were determined during storage. Results: Our data indicate a quality of leukocyte-depleted whole blood donations comparable to buffy-coat-free red blood cell units. Conclusions: The Leukotrap Al whole blood filter system is an interesting option for hospitals lacking the technical capacity to separate whole blood into components. The clinical suitability remains to he investigated by means of clinical studies.
引用
收藏
页码:979 / 982
页数:4
相关论文
共 50 条
  • [21] LEUKOCYTE DEPLETION OF BLOOD PRODUCTS AND POSTTRANSFUSION INFECTIONS
    GIRARD, A
    REVUE FRANCAISE DE TRANSFUSION ET D HEMOBIOLOGIE, 1993, 36 (03): : 265 - 279
  • [22] Efficacy of leukocyte depletion of residual pump blood
    Heerdt, EM
    Fransen, EJ
    Maessen, JG
    de Jong, DS
    PERFUSION-UK, 2004, 19 (01): : 3 - 5
  • [23] EVALUATION OF A NEW FILTER FOR LEUKOCYTE DEPLETION OF BLOOD
    JOHNSON, J
    MIJOVIC, V
    BROZOVIC, B
    JOURNAL OF CLINICAL PATHOLOGY, 1983, 36 (10) : 1200 - 1201
  • [24] In vitro comparison of cold-stored whole blood and reconstituted whole blood
    Susila, Sanna
    Helin, Tuukka
    Lauronen, Jouni
    Joutsi-Korhonen, Lotta
    Ilmakunnas, Minna
    VOX SANGUINIS, 2023, 118 (07) : 523 - 532
  • [25] EFFECTS OF LEUKOCYTE DEPLETION ON CORNEAL NEOVASCULARIZATION
    SHOLLEY, MM
    GIMBRONE, MA
    COTRAN, RS
    LABORATORY INVESTIGATION, 1978, 38 (01) : 32 - 40
  • [26] The quality of stored umbilical cord and adult-donated whole blood in Mombasa, Kenya
    Hassall, Oliver
    Maitland, Kathryn
    Fegan, Gregory
    Thitiri, Johnstone
    Pole, Lewa
    Mwakesi, Robert
    Denje, Douglas
    Wambua, Kongo
    Mandaliya, Kishor
    Bates, Imelda
    TRANSFUSION, 2010, 50 (03) : 611 - 616
  • [27] THE EFFECTS OF VARIOUS ANTIOXIDANTS ON LIPID-PEROXIDATION IN STORED WHOLE-BLOOD
    KNIGHT, JA
    SEARLES, DA
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 1994, 24 (04): : 294 - 301
  • [28] STORED WHOLE-BLOOD OR ERYTHROCYTE CONCENTRATE
    SEIDL, S
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1977, 102 (17) : 669 - 670
  • [29] PH OF WHOLE BLOOD STORED IN PLASTIC CONTAINERS
    MOORE, BPL
    PATH, FC
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 1967, 97 (24) : 1492 - &
  • [30] ERYTHROCYTE CONCENTRATE OR WHOLE STORED-BLOOD
    LUNDSGAARDHANSEN, P
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1982, 107 (22) : 874 - 874